IMPACT BIOSYSTEMS PACT User Manual

Sense muscle scanner

Advertisement

Quick Links

User Manual
Pact Sense Muscle Scanner
PLEASE READ ALL INSTRUCTIONS PRIOR TO USE
v1.1
Oct 2022
Impact Biosystems, Inc.
5 Colebrook St. Boston, MA 02127
www.thepact.com
support@thepact.com
1

Advertisement

Table of Contents
loading

Summary of Contents for IMPACT BIOSYSTEMS PACT

  • Page 1 User Manual Pact Sense Muscle Scanner PLEASE READ ALL INSTRUCTIONS PRIOR TO USE v1.1 Oct 2022 Impact Biosystems, Inc. 5 Colebrook St. Boston, MA 02127 www.thepact.com support@thepact.com...
  • Page 2: Table Of Contents

    Table of Contents Table of Contents Important Safety Information Quick Start Operation Limited Warranty Maintenance Storage Technical Specifications Device Firmware Troubleshooting Change Log Impact Biosystems, Inc. 5 Colebrook St. Boston, MA 02127 www.thepact.com support@thepact.com...
  • Page 3: Important Safety Information

    12. This device is not a toy. Adult supervision required. Children should be supervised to ensure that they do not play with the device 13. Use product only according to Instructional Use materials at https://thepact.com. Impact Biosystems, Inc. 5 Colebrook St. Boston, MA 02127 www.thepact.com...
  • Page 4: Quick Start

    USB-C charging port located on the back of the device. The light’s color will indicate the charge level. A red blinking light indicates that the device must be charged before use. Setup the Pact Mobile App Scan the QR Code to install the app. Follow in-app instructions to create your account. https://thepact.com/getting-started Impact Biosystems, Inc.
  • Page 5 ● One Hard Shell Carry Case ● One Quick Start Guide bearing QR code access to the user manual If the package does not contain each of the items listed above, contact the Pact customer support team immediately. Impact Biosystems Inc.
  • Page 6: Operation

    To power on: press and hold button for 2 second until LED turns on 2. Enable Bluetooth on your mobile device 3. Use the Pact App to connect to your Sense ○ The Status LED will glow white when it is connected 4.
  • Page 7 This usually means the app requires attention before you can complete the next scan CAUTION: Immediately stop using the Pact Sense if you experience any pain or discomfort from using the device. Avoid using the Pact Sense on bruises, contusions, rashes, or irritated or injured areas of the body until they are fully healed.
  • Page 8: Limited Warranty

    Impact Biosystems, Inc. (“Company” or “we”) warrants to the original purchaser or gift recipient only that the Pact Sense Device (the “Product”) you purchased from Company shall be free from defects in materials and workmanship under normal use for a period of one (1) year from the date of retail purchase by the original purchaser (“Warranty Period”), as documented by a valid proof of...
  • Page 9 This Limited Warranty applies only to Products manufactured by or for Company that can be identified by the Pact trademark, trade name, or logo affixed to it. The Limited Warranty does not apply to, and the term “Product” shall not include, any (a) Company products and services other than the Product, or (b) software, even if packaged or sold with the Product or embedded in the Product (e.g., firmware and/or system...
  • Page 10 Limited Warranty. If you have any questions, please contact the Company at: support@thepact.com. Please view the full terms and conditions of the limited warranty at: https://www.thepact.com/warranty Impact Biosystems, Inc. 5 Colebrook St. Boston, MA 02127 www.thepact.com support@thepact.com...
  • Page 11: Maintenance

    Maintenance Cleaning the Measurement Probe The external surfaces of the Pact Sense can be cleaned with a dry soft cloth. Avoid getting water and other liquids inside the device. Alcohol wipes can be used to disinfect surfaces that come in contact with skin, such as the measurement probe and moving ring.
  • Page 12: Storage

    ● Operating temperature: 5 ℃ - 40 ℃ (40 ℉ - 105 ℉) ● Relative air humidity: 0 - 50% RH ● When not stored in the carry case, the Pact Sense should be placed on a flat surface with the moving ring side facing down (as seen below).
  • Page 13: Technical Specifications

    Measurement probe force/pressure ● 0 - 5 N / 64 kPa Measurement method ● The Pact Sense applies a proprietary force waveform to the tissue and measures the underlying tissue response Measurable parameters ● Stiffness [N/m] — Amount of force produced by the skin, as a result of the measurement probe depressing into the tissue ●...
  • Page 14 While the device is charging, the LED will indicate charge status: WARNING: For the purposes of recharging the battery, only use the detachable supply unit provided with this appliance. Impact Biosystems, Inc. 5 Colebrook St. Boston, MA 02127 www.thepact.com support@thepact.com...
  • Page 15 Dimensions and Weight Product: Height 110 mm Diameter 70 mm Weight 340 g Packaging Height 75 mm Width 100 mm Impact Biosystems, Inc. 5 Colebrook St. Boston, MA 02127 www.thepact.com support@thepact.com...
  • Page 16: Device Firmware

    550 g Device Firmware Firmware Upgrades Turn the Pact Sense on and connect to it via Bluetooth using the Pact Mobile App. 2. Go to Settings by clicking the gear icon 3. Click on “Update Firmware” 4. Follow the on-screen instructions to complete the update process Troubleshooting for help with firmware update issues...
  • Page 17: Troubleshooting

    Cleaning/Test Mode ● Power the device on ● Do NOT connect the device the Pact Muscle Recovery app ● Enter cleaning/test mode by triple tapping the button ● Use an alcohol wipe to gently clean probe ● Single tap the button to exit cleaning/test mode ●...
  • Page 18: Change Log

    Change Log Version Change v1.1 ● Update warranty information Update figures ● ● Formatting updates v1.0 Initial Release ● Impact Biosystems, Inc. 5 Colebrook St. Boston, MA 02127 www.thepact.com support@thepact.com...

Table of Contents