ADANI SYSTEMS CLEARPASS Operation Manual

ADANI SYSTEMS CLEARPASS Operation Manual

Full-body security screening system

Advertisement

FULL-BODY SECURITY SCREENING SYSTEM
OPERATION MANUAL
ADN190.00.00.000 OM2
«CLEARPASS»
Identification
ADN190.00.00.000 OM2
ADANI Systems, Inc.
13631 Poplar Circle
Conroe, Texas 77304
Technical Support
Tel. 844.989.6789
support@adanisystems.com
Sales Inquiries
Tel. 936.588.2064
sales@adanisystems.com
Revision
Date
1
02.2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLEARPASS and is the answer not in the manual?

Questions and answers

GABRIEL GUILLERMO
March 18, 2025

is there a section in the manual that has error codes

1 comments:
Mr. Anderson
May 14, 2025

No, the provided context does not show a section on error codes in the ADANI SYSTEMS CLEARPASS manual.

This answer is automatically generated

BOBBY BROOKS
March 5, 2025

im getting a detector error

1 comments:
Mr. Anderson
May 14, 2025

A detector error in the ADANI SYSTEMS CLEARPASS indicates a failure in the X-ray detector, which is a multipurpose photodiode array element with a scintillation coating. This component measures the total energy of X-ray photons. A detector error may affect the system's ability to accurately detect contraband and should be addressed by contacting the service provider, as system operation is forbidden in case of such failures.

This answer is automatically generated

Summary of Contents for ADANI SYSTEMS CLEARPASS

  • Page 1 FULL-BODY SECURITY SCREENING SYSTEM OPERATION MANUAL ADN190.00.00.000 OM2 «CLEARPASS» ADANI Systems, Inc. 13631 Poplar Circle Conroe, Texas 77304 Technical Support Tel. 844.989.6789 support@adanisystems.com Sales Inquiries Tel. 936.588.2064 sales@adanisystems.com Revision Identification Date ADN190.00.00.000 OM2 02.2022...
  • Page 2 Full-Body Security Screening System This Operation Manual ADN190.00.00.000 ОМ contains the information necessary to operate the full-body security screening system «CLEARPASS» (hereafter, referred to as the System). The manual is intended for personnel working with the System and service specialists,...
  • Page 3: Table Of Contents

    CLEARPASS Full-Body Security Screening System TABLE OF CONTENTS TABLE OF CONTENTS ...................... 3 GENERAL ........................ 8 INTENDED USE ..................... 8 GENERAL SYSTEM SPECIFICATION ............8 IDENTIFICATION ..................11 SAFETY ........................14 GENERAL ....................14 RESPONSIBILITIES ..................14 RADIATION SAFETY ................... 15 ELECTRICAL SAFETY ................
  • Page 4 CLEARPASS Full-Body Security Screening System 5.3. EMERGENCY SHUTDOWN ................ 44 MAINTENANCE ..................... 46 6.1. GENERAL ....................46 6.2. SAFETY INSTRUCTIONS WHEN PERFORMING THE MAINTENANCE ... 46 6.3. MAINTENANCE PROCEDURE..............46 6.4. PERIODIC MAINTENANCE ................. 48 6.5. DISPOSAL ....................49 TECHNICAL SPECIFICATIONS ................51 7.1.
  • Page 5 CLEARPASS Full-Body Security Screening System SAFETY AND INFORMATIONAL NOTATION The following safety and informational notations are used in this manual. Their descrip- tion is provided below. INDICATES HAZARDOUS SITUATIONS WHICH, AVOIDED, WILL RESULT IN DEATH OR SERIOUS INJURY. INDICATES SITUATIONS WHICH, IF NOT AVOIDED, COULD CAUSE SERIOUS PERSONAL INJURY AND/OR DAMAGE TO THE EQUIPMENT OR DATA.
  • Page 6 CLEARPASS Full-Body Security Screening System X-RAY PROTECTION IF X-RAY PROTECTION MEASURES ARE NOT OBSERVED, THE SYSTEM MAY BE DANGEROUS TO PERSONNEL WORKING WITH IT AND TO THIRD PARTIES. The System is designed in compliance with national and international radiation safety standards.
  • Page 7 CLEARPASS Full-Body Security Screening System GENERAL SELECTION 1 OPERATION Identification Revision Date Page MANUAL ADN190.00.00.000 OM2 02.2022 7 of 52...
  • Page 8: General

    CLEARPASS Full-Body Security Screening System GENERAL INTENDED USE The System is designed for obtaining projection radiographic images of a person in full height. The general view of the System without Operator’s Acquisition/Analysis workstation (fur- ther Operator’s AWS) is shown in Figure 1.1.
  • Page 9 CLEARPASS Full-Body Security Screening System X-ray tube module including: − X-ray generator; − X-ray detector; − beam-limiting unit with the X-ray protective shutter (option) and dosimeter (option); − system controller; − distribution panel; − rotary mechanism. Operator’s AWS; A detailed description of the System design, location and purpose of its main functional parts and controls is in the Section 3.
  • Page 10 CLEARPASS Full-Body Security Screening System Side view Top view Figure 1.2 – X-Rays Path during Scanning 1.2.3 Software features The System software implements modern digital technologies of System control, making it possible to acquire, process and store X-ray images. The software package is an original specialized software and provides a full set of features for effective personal inspection: −...
  • Page 11: Identification

    CLEARPASS Full-Body Security Screening System − obtaining the X-ray image of a person in full height; − repeated screenings of the same person throughout a year due to the low radiation dose; − high detectability; − detecting any items (including plastic explosive) hidden on the body or within clothes as well as inside a human body (swallowed or hidden in body cavities) at a single inspection;...
  • Page 12 CLEARPASS Full-Body Security Screening System The location of the symbols and identification plate on the System is shown in Figure 1.4. Figure 1.4 – Location of the Identification Plate and Symbols on the System OPERATION Identification Revision Date Page MANUAL ADN190.00.00.000 OM2...
  • Page 13 CLEARPASS Full-Body Security Screening System SAFETY SELECTION 2 OPERATION Identification Revision Date Page MANUAL ADN190.00.00.000 OM2 02.2022 13 of 52...
  • Page 14: Safety

    CLEARPASS Full-Body Security Screening System SAFETY GENERAL The design of the System ensures its safe operation. The personnel working with the System must be familiar with the current standards, rules and instructions on safety measures, have special training on these issues, know the safety measures required when working with X-ray equipment and undergo the retraining periodically.
  • Page 15: Radiation Safety

    CLEARPASS Full-Body Security Screening System ADANI SYSTEMS IS NOT LIABLE FOR OVEREXPOSURE OF THE INSPECTED PEOPLE OR PERSONNEL OBTAINED DURING SYSTEM OPERATION RESULTING FROM ITS MISUSE. ADANI SYSTEMS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY CONSEQUENCES CAUSED BY THE USE OF SYSTEM...
  • Page 16 CLEARPASS Full-Body Security Screening System Code of Federal Regulations (CFR), Title 21, Subchapter J (Title 21 CFR § 1000 – 1005). Technical Solutions on Ensuring Radiation Protection The System has the following design features to minimize radiation doses to personnel and inspected persons: X-ray generator protected by the housing;...
  • Page 17 CLEARPASS Full-Body Security Screening System surfaces of the System, at the personnel workplaces, at the edge of the inspection zone and in allied premises. Such measures should be taken in accordance with current practices in the buyer's coun- try, at least once a year, and after the System installation before taking it into operation, after repairing or replacing spare parts, after moving the System to another location, or after mechanical damage caused by impact.
  • Page 18 CLEARPASS Full-Body Security Screening System Accumulated reference effective dose per 12-month period In case the accumulated reference effective dose per individual reaches 250 μSv (25 mrem) over a 12-month period – no more scans are permitted for this individual. The system allows you to preset the mode of operation – 0.1 μSv (10 μrem) per scan (optional).
  • Page 19 CLEARPASS Full-Body Security Screening System Table 2.2 Radiation Dose, Dose Increase Radiation Source µSv 50,000 (max.) cranium X-ray tomography 10,000 (usual) 5,000 (max.) dental radiography 1,000 (usual) 400 (max.) chest radiography 100 (usual) Flight Time, h London-New-York 7,30 New-York - Los Angeles...
  • Page 20 CLEARPASS Full-Body Security Screening System 2.3.3 Inspection zone The operator responsible for the scanning should be provided with the necessary means to visually monitor the inspection zone, which is enclosed by a virtual or real wall. The edges of the inspection zone around the System must be marked, and no unauthor- ized personnel will be allowed to access it during equipment operation.
  • Page 21 CLEARPASS Full-Body Security Screening System NO UNAUTHORIZED PERSONS (NON-STAFF PERSONNEL) ARE ALLOWED TO BE WITHIN THE INSPECTION ZONE DURING THE SYSTEM OPERATION Identification of the sanitary protection zone around the system where the ambient dose equivalent is greater than 0.5 µSv in 1 hour of operation at the maximum throughput at maximum operation conditions.
  • Page 22 CLEARPASS Full-Body Security Screening System 2.3.4 Principles of radiation protection The following principles of radiation protection are used in the System: System has an indicator (a red lamp) indicating that the scanning is in progress. Power supply to the System is controlled by a key switch. When the scanning is initi- ated, the key is captured.
  • Page 23: Electrical Safety

    CLEARPASS Full-Body Security Screening System ELECTRICAL SAFETY The System complies with the electrical safety requirements established in Low Voltage Directive 2014/35/EU and technical standard EN 61010-1:2010. By the type of protection against electric shock the System refers to Class I accord-ing to EN 61010-1:2010.
  • Page 24: Fire Safety

    CLEARPASS Full-Body Security Screening System FIRE SAFETY The materials used in the components and the design are selected so that when oper- ating under normal load, the temperatures do not exceed safe values. In the System, construc- tive solutions are used to reduce the risk of ignition and flame propagation in accordance with IEC 60950-1 (section 4.7).
  • Page 25: Emergency Actions

    CLEARPASS Full-Body Security Screening System Any inconsistent changes to the hardware and software included System (including programs installation, uninstallation, data deletion, not provided for in the procedure for working with the System described in the operating documentation for the System) are equivalent to a change in the System design and exclude the manufacturer's obligation to provide warranty repairs.
  • Page 26 CLEARPASS Full-Body Security Screening System SYSTEM DESCRIPTION SELECTION 3 OPERATION Identification Revision Date Page MANUAL ADN190.00.00.000 OM2 02.2022 26 of 52...
  • Page 27: System Description

    CLEARPASS Full-Body Security Screening System SYSTEM DESCRIPTION This section describes the design of the System as well as the location and purpose of its main functional parts. The major functional parts of the System are as follows (see Figure 3.1): Framework;...
  • Page 28: Framework

    CLEARPASS Full-Body Security Screening System Figure 3.1 – Major Functional Parts of the System (without the Operator’s AWS) FRAMEWORK Framework (see Figure 3.2) is intended for mounting the main System parts. The frame- work may be divided into four areas: The base plate (position 1, see Figure 3.2) is for mounting the System on working...
  • Page 29: External Covers

    CLEARPASS Full-Body Security Screening System subject to severe mechanical influences in the process of operation. Figure 3.3 – Portal The portal may optionally include a video camera for real-time inspection monitoring and saving images to the CONPASS database. EXTERNAL COVERS The external covers (see Figure 3.4) of the System restrict access to the internal com-...
  • Page 30: X-Ray Tube Module

    CLEARPASS Full-Body Security Screening System 1 – Signal Lamp, the Scanning Process Start; 2 – Signal lamp, Readiness of the System for Operation Figure 3.4 – Signal Lamp Assemblies The System external covers are equipped with a panel to control cables and power sup- ply cables output.
  • Page 31 CLEARPASS Full-Body Security Screening System 1 – Rotary mechanism; 2 – X-ray Detector; 3 – Rotary frame; 4 – Collimator output slit; 5 – X-ray generator with Beam-limiting unit; 6 – Electrics Figure 3.5 3.4.1 Rotary frame The rotary frame (see Figure 3.6) is a rigid structure made of metal profile. The rotary frame is intended for securing the main components and systems of the System.
  • Page 32 CLEARPASS Full-Body Security Screening System Figure 3.6 3.4.2 X-ray detector The X-ray detector (see Figure 3.7) is a multipurpose photodiode array element with scintillation coating. The current of the photodiodes is proportional to the total energy of the X- ray photons crossing the volume of the scintillator and characterizes the level of the X-ray ab- sorbed by the object.
  • Page 33 CLEARPASS Full-Body Security Screening System 1 – Data Acquisition Unit; 2 – Photodiode Array Figure 3.7 The number of X-ray sensitive elements (photodiode-scintillator combination) is charac- terized by the number of elements (pixels) of a digital image. During the scanning process, the output signal of each element is successively read, digitalized by the electronic interface unit and stored, thus creating one digital imaging column on the display.
  • Page 34 CLEARPASS Full-Body Security Screening System 3.4.3 X-ray generator The X-ray generator (see Figure 3.8) is intended for generating the X-ray beam with the specified field geometry and given exposure parameters for full height person scanning. 1 – X-ray Generator; 2 – Generator Control Unit; 3 – X-ray Generator Mounting Mechanism;...
  • Page 35 CLEARPASS Full-Body Security Screening System Constructively, the beam-limiting unit is a system intended to: − Obtain an X-ray beam with the required geometry; − Control the opened/closed state of the entrance slit diaphragm, provided the X-ray shut- ters are used;...
  • Page 36 CLEARPASS Full-Body Security Screening System 1 – Distribution panel; 2 – NetCom Board; 3 – Ethernet Commutator; 4 – System Controller; 5 – Electric Motor of Rotary Mechanism Controller. Figure 3.9 – Electrics 3.4.5 Rotary mechanism The rotary mechanism consists of an electric motor (position 5 see Figure 3.10), the torque of which is transmitted through the coupling using a belt (position 4 see Figure 3.10) to...
  • Page 37: Operator's Acquisition/Analysis Workstation (Operator'saws)

    CLEARPASS Full-Body Security Screening System 1 – The Upper Rotary Unit; 2 – Shaft; 3 – Lower Rotary Unit; 4 – Belt; 5 – The Electric Motor of The Rotary Mechanism. Figure 3.10 – Rotary Mechanism OPERATOR’S ACQUISITION/ANALYSIS WORKSTATION (OPERA- TOR’S AWS)
  • Page 38: Video Surveillance Camera (Option)

    CLEARPASS Full-Body Security Screening System The Operator’s computer is connected to the System’s components via Ethernet port and serial ports. It can be located in the immediate vicinity of the System or in a separate room. The Operator’s AWS is intended to: −...
  • Page 39 CLEARPASS Full-Body Security Screening System SETUP PROCEDURES SELECTION 4 OPERATION Identification Revision Date Page MANUAL ADN190.00.00.000 OM2 02.2022 39 of 52...
  • Page 40: Setup Procedures

    CLEARPASS Full-Body Security Screening System 4 SETUP PROCEDURES STARTUP Before starting the operation, check the ambient temperature in the room where the System has been installed. If the temperature is below +10°C, heat the room to the operating temperature (see section 7.3) and season the System for at least 2 hours.
  • Page 41 CLEARPASS Full-Body Security Screening System When using an Operator’s AWS without Operator’s Stand Enable the Scanner and the Operator’s AWS following the sequence below: Ensure the System is connected to the mains. Insert the key 1 (see Figure 4.2) in the “0-l” switch on the control box and turn it clockwise until it stops.
  • Page 42 CLEARPASS Full-Body Security Screening System OPERATION SELECTION 5 OPERATION Identification Revision Date Page MANUAL ADN190.00.00.000 OM2 02.2022 42 of 52...
  • Page 43: Operation

    CLEARPASS Full-Body Security Screening System OPERATION 5.1. PEROFRMING THE SCANNING The scanning should be performed following the sequence below: 1) Register an individual to be inspected using the Operator’s Program in accordance with the Operator’s Manual. 2) Place the inspected individual on the moveable platform or the conveyor belt as shown in Figure 5.1.
  • Page 44: Emergency Shutdown

    CLEARPASS Full-Body Security Screening System − Turn the key on the control panel counterclockwise. The green indicator lamp will go out. 5.3. EMERGENCY SHUTDOWN If the following window appears on the screen: Figure 5.2 – NetCom window it means that connection with some parts of the system was lost was lost.
  • Page 45 CLEARPASS Full-Body Security Screening System MAINTENANCE SELECTION 6 OPERATION Identification Revision Date Page MANUAL ADN190.00.00.000 OM2 02.2022 45 of 52...
  • Page 46: Maintenance

    CLEARPASS Full-Body Security Screening System MAINTENANCE 6.1. GENERAL The types of the inspections and maintenance (further referred to as the maintenance) mentioned below, as well as the suggested time intervals are compulsory, serving the ensuring of performance and safety, timely warning of the possibility of failure or deterioration of func- tioning.
  • Page 47 CLEARPASS Full-Body Security Screening System power cords, as well as visually inspect the monitor of the Operator’s AWS and System control console. It should be ensured that the emergency stop buttons are not damaged and correctly positioned (see Figure 2.1 and Figure 4.1). The buttons must be free of damage and depressed.
  • Page 48: Periodic Maintenance

    CLEARPASS Full-Body Security Screening System 6.4. PERIODIC MAINTENANCE Maintenance tasks and time intervals are provided in Table 6.1. Annual M3 include also works from M2. When performing M3 no further M2 is required within this period. Table 6.1 – Maintenance Tasks and Time Intervals...
  • Page 49: Disposal

    CLEARPASS Full-Body Security Screening System 6.5. DISPOSAL 6.5.1. Safety Precautions To disassemble the components of the System for purposes of disposal, you should adhere to the following safety precautions: Switch OFF the system and disconnect the power cable. Use ONLY serviceable tools when disassembling.
  • Page 50 CLEARPASS Full-Body Security Screening System TECHNICAL SPECIFICATION SELECTION 7 OPERATION Identification Revision Date Page MANUAL ADN190.00.00.000 OM2 02.2022 50 of 52...
  • Page 51: Technical Specifications

    CLEARPASS Full-Body Security Screening System TECHNICAL SPECIFICATIONS 7.1. GENERAL Parameter / characteristics, units Value length 87.4” (2220 mm) Dimensions, max width 63” (1600 mm) height 94.5” (2400 mm) Weight, max 1874 lbs (850 kg) Supply ratings: Current type, phase number...
  • Page 52: Operator's Computer

    CLEARPASS Full-Body Security Screening System 7.2. OPERATOR’S COMPUTER Acquisition workstation technical specifications are to be found in Control Software Com- plex, Operator's Manual. At the request of the customer, individual configuration of a computer with improved characteristics may be performed.