Dehumidifier Set Up - Trane EDHUM070H Installation & Operation Instructions

Table of Contents

Advertisement

Important Precautions
• The device is designed to be installed indoors in a space that is protected from rain and flooding.
• Install the unit with enough space to access all sides for maintenance and service. The entire shell needs to be
removed in order to do repairs.
• Avoid directing the discharge air at people. The dehumidifier should be used in the upright position.
• If used near a water source; be certain there is no chance the unit could fall into the water or get splashed and
that it is plugged into a dedicated circuit and Ground Fault Circuit Interrupter (GFCI) protected outlet.
• DO NOT use the dehumidifier as a bench or table.
• DO NOT place the dehumidifier directly on structural building members without vibration absorbers or unwanted
noise may result. Place the EDHUM070H on supports to raise the base of the unit.
• A drain pan with a float switch MUST be placed under the dehumidifier if installed above a living area or above
an area where water leakage could cause damage.
Location Considerations
• Allow sufficient clearance to handle the unit's overall dimensions as well as the necessary return and supply
ductwork to the unit.
• Allow sufficient clearance for filter removal and to prevent airflow obstruction.
• Electrical service access will require the removal of the outside shell. Allow sufficient clearance around the unit.
• Locate the dehumidifier in an area where the cord's lenght (9') easily reaches a 115 VAC electrical outlet with a
minimum of a 15 Amp circuit capacity.
• Locate the dehumidifier in an area where field wiring the control (low voltage) to the unit will be possible.
• It is recommended that a
backdraft damper be used in
the discharge duct of the
EDHUM070H, especially when
connecting to the supply
ducting system. The backdraft
damper prevents supply air
from counter flowing through
the EDHUM070H when it is not
operating. The dehumidifier's
location should be chosen to
allow installation of this
accessory if necessary.
• The EDHUM070H may be
suspended with the hang kit
or a suitable alternative from
structural members,
ensuring the assembly
supports the dehumidifier's
base in its entirety. DO NOT
hang the EDHUM070H from
its' cabinet.
• Allow for proper drainage and
routing of needed drain pipes.

DEHUMIDIFIER SET UP

A
DRAIN
ACCESS
MINIMUM
CLEARANCE
FOR FILTER
(EITHER SIDE)
6" MINIMUM CLEARANCE
FOR PROPER AIR FLOW
TOP VIEW
13"
FILTER
A
B
ELECTRICAL SERVICE
ACCESS THIS SIDE
9' POWER CORD
RETURN AIR DUCT
SUPPLY AIR DUCT
18-HE133D1-1A-EN
B
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents