  • Page 1 Original operating instructions UDI Panel ® ® PRESSOTECHNIK GmbH & Co. KG Riedstrasse 4 88250 Weingarten / Germany www.tox-pressotechnik.com...
  • Page 2 TOX_Manual_TOX UDI Panel_en...
  • Page 3: Table Of Contents

    Table of contents Table of contents Important information Legal note .................... 7 Exclusion of liability.................. 7 Conformity .................... 7 Validity of the document ................ 8 1.4.1 Content and target group................ 8 1.4.2 Other applicable documents ................ 8 Gender note.................... 8 Displays in the document................ 9 1.6.1 Display of warnings.................. 9 1.6.2 Display of general notes ................ 10 1.6.3...
  • Page 4 3.2.2 Product overview 13.3 / 21.5 inch.............. 21 Touch screen ..................... 22 Technical data Type sheet and data sheet ................ 23 ® Connections 10.1 inch TOX UDI Panel ........... 23 ® 4.2.1 Supply voltage 10.1 inch TOX UDI Panel.......... 23 ® 4.2.2 Data interface 10.1 inch TOX UDI Panel .......... 24...
  • Page 5 Table of contents Establishing VNC connection .............. 44 Maintenance Requirements for maintenance and cleaning .......... 45 Cleaning the touch screen ................. 45 ® Update TOX Software................ 46 Disassembly and Disposal Disposal ..................... 47 Appendices 10.1 Declaration of conformity ................ 49 Index TOX_Manual_TOX UDI Panel_en...
  • Page 6 Table of contents TOX_Manual_TOX UDI Panel_en...
  • Page 7: Important Information

    Important information 1 Important information 1.1 Legal note All rights reserved. Operating instructions, manuals, technical descriptions and software pub- ® ® lished by TOX  PRESSOTECHNIK GmbH & Co. KG ("TOX  PRES- SOTECHNIK") are copyright and must not be reproduced, distributed and/ or otherwise processed or edited (e.g.
  • Page 8: Validity Of The Document

    Important information 1.4 Validity of the document 1.4.1 Content and target group This manual contains information and instructions for the safe operation and safe maintenance or servicing of the product. Ÿ All information in this manual is up to date at the time of print. ®...
  • Page 9: Displays In The Document

    Important information 1.6 Displays in the document 1.6.1 Display of warnings Warning signs indicate potential dangers and describe protective mea- sures. Warning signs precede the instructions for which they are applicable. Warning signs concerning personal injuries DANGER Identifies an immediate danger! Death or severe injuries will occur if appropriate safety measures are not taken.
  • Page 10: Display Of General Notes

    Important information 1.6.2 Display of general notes General notes show information on the product or the described action steps. Identifies important information and tips for users. 1.6.3 Highlighting of texts and images The highlighting of texts facilitates orientation in the document. ü...
  • Page 11: Contact And Source Of Supply

    Important information 1.7 Contact and source of supply ® Only use original spare parts or spare parts approved by TOX  PRES- SOTECHNIK. ®  PRESSOTECHNIK GmbH & Co. KG Riedstraße 4 88250 Weingarten / Germany Tel. +49 (0) 751/5007-333 E-Mail: info@tox-de.com For additional information and forms see www.tox-pressotechnik.com TOX_Manual_TOX UDI Panel_en...
  • Page 12 Important information TOX_Manual_TOX UDI Panel_en...
  • Page 13: Safety

    Safety 2 Safety 2.1 Basic safety requirements The product is state of the art. However, operation of the product may in- volve danger to life and limb for the user or third parties or damage to the plant and other property. For this reason the following basic safety requirements will apply: Ÿ...
  • Page 14: Selection And Qualifications Of Personnel

    Safety Ÿ Take action to ensure safe operation and make sure that the product is maintained in a functional condition. Ÿ Only allow authorized persons access to the product. Ÿ Ensure that all personnel work with awareness of safety and potential dangers with reference to the information in the operating manual.
  • Page 15: Fundamental Hazard Potential

    Safety 2.3 Fundamental hazard potential Fundamental hazard potentials exist. The specified examples draw atten- tion to known hazardous situations, but are not complete and do not in any way provide safety and risk awareness action in all situations. 2.3.1 Electrical hazards Attention should be paid to electrical hazards particularly inside the compo- nents in the area of all assemblies of the control system and motors of the installation.
  • Page 16: Special Types Of Risks

    Safety 2.4 Special types of risks 2.4.1 Electrical energy The following safety requirements must be observed for all work on electri- cal equipment: Ÿ Have work on electrical equipment performed only by electricians or trained persons under the direction and supervision of an electrician in accordance with the electrotechnical regulations.
  • Page 17: Mechanical Damage

    Safety 2.4.4 Mechanical damage Ÿ Do not place the touchpanel on the operating side, since this could damage the control elements mechanically or activate them uninten- tionally. Ÿ Never place the touchpanel on unstable surfaces or storage spaces. It could fall down and sustain damage. Ÿ...
  • Page 18 Safety TOX_Manual_TOX UDI Panel_en...
  • Page 19: About This Product

    About this product 3 About this product 3.1 Intended use ® The TOX UDI Panel is a portable operating and display unit and makes in- tuitive operation possible. 3.1.1 Safe and correct operation Intended use includes the following conduct: Ÿ...
  • Page 20: Substances Harmful To The Wetting Properties Of Lacquers (Labs)

    About this product 3.1.3 Substances harmful to the wetting properties of lacquers (LABS) No substances containing silicone, are knowingly processed and used. 3.2 Product overview and function description 3.2.1 Product overview 10.1 inch Fig. 1 Product overview 10.1 inch Designation Function USB connection For connecting, e.g.
  • Page 21: Product Overview 13.3 / 21.5 Inch

    About this product 3.2.2 Product overview 13.3 / 21.5 inch Fig. 2 Product overview 13.3 / 21.5 inch Designation Function Touch screen Visualization of control surface and operation Cover Cable bushing Feed-through for communication cables and volt- age supply cables. USB connection For connecting, e.g.
  • Page 22: Touch Screen

    About this product 3.3 Touch screen The touch panel has a capacitive touch screen. The touch screen can be operated with the fingers or with a touch pin (ca- pacitive). To ensure a long service life of the touch screen, note the follow- ing: NOTE Touch damage due to improper handling!
  • Page 23: Technical Data

    Pin assignment wall housing ® The 10.1 inch TOX UDI Panel is delivered ready to be plugged. The following pin assignment is for a plug connector for feeding though a wall (not included in delivery, recommended are Harting, type: Han 3M RJ45 Hybrid Cat.6 PFT 8+4p EMV-P).
  • Page 24: Data Interface 10.1 Inch Tox ® Udi Panel

    Data interface 10.1 inch TOX ® UDI Panel ® The 10.1 inch TOX UDI Panel is connected to the data cable via an RJ45 connector. For the associated wall feed-through the data cable 1:1 is fed through via the RJ45 connectors. 4.3 Connecting line...
  • Page 25: Transport And Storage

    Transport and storage 5 Transport and storage 5.1 Temporary storages Ÿ Use original packaging. Ÿ Make sure that all electrical connections are covered to prevent dust ingress. Ÿ Protect the display against sharp-edged objects e.g. due to cardboard or hard foam. Ÿ...
  • Page 26 Transport and storage TOX_Manual_TOX UDI Panel_en...
  • Page 27: Installation

    Avoid tripping points when setting up. è Mark unavoidable tripping points with warning sign. WARNING Safe extra-low voltage of function ® The TOX UDI Panel must be operated with safe extra-low voltage of func- tion (SELV, PELV). TOX_Manual_TOX UDI Panel_en...
  • Page 28: Requirements For Installation

    Installation 6.2 Requirements for installation 6.2.1 Set-up location The set-up location: Ÿ Must be free from dust and dirt Ÿ Must be a closed room Ÿ Must have a firm, level floor Ÿ Must have sufficient space and easy access to the system parts Ÿ...
  • Page 29: Installation13.2 Inch / 21.5 Inch Tox Udi Panel

    Installation 6.3 Installation13.2 inch / 21.5 inch TOX UDI Panel ® 6.3.1 Preparation of the installation cutout The resistance of the material of the installation cutout must be sufficiently high. For the dimensions of the fastening holes see data sheet. www.tox-pres- sotechnik.com...
  • Page 30 Installation When installing the housing cover, observe the following: Ÿ Prevent squashing or damage of the connecting line. Ÿ Prevent the guide of cables over sharp edges which can rub open the cable jacket. TOX_Manual_TOX UDI Panel_en...
  • Page 31: Installing Connections

    Installation 6.3.3 Installing connections Connect TOX ® UDI Panel DANGER Explosion Death or serious injuries! è The USB connection must not be used in an explosive atmosphere. CAUTION Faults of external power supply, signal or cables of periphery devices occur.
  • Page 32 Installation Performance of dismantling / installation Change of the protection type If 2 Ethernet cables are to be connected, the enclosed double feed-through can be used. When using the double feed-through the protection class is reduced to IP54. Fig. 5 Performance of dismantling / installation ü...
  • Page 33 Installation Supply voltage connection + 24 VDC 0 VDC Fig. 6 Supply voltage connection ü Cross-section of wires from 0.75 mm² to 1.5 mm² 1. Strip wires to 7 mm. 2. Insert the wires into the connection contacts of the plug connector. 3. Tighten the screw contacts with a screwdriver. Tightening torque 0.3 Nm.
  • Page 34 Installation ® Customer network / data interface on 13.2 inch TOX UDI Panel ® Customer network / data inter- Connection of TOX Power- face Module ® Fig. 7 Customer network / data interface 13.2 inch TOX UDI Panel ® 1. Attach cable of customer network and TOX PowerModule.
  • Page 35: Grounding Connection / Potential Equalization

    Installation 6.3.4 Grounding connection / potential equalization NOTE Grounding / potential equalization not connected. Functionality of device not guaranteed. è All grounding connections / potential equalization must be connected with a grounding point. A cable to the central grounding point / potential equalization of the switch cabinet or the plant must be installed on the grounding connection.
  • Page 36: Holder Installation Vesa

    Installation 6.3.5 Holder installation VESA Fig. 9 Installation of VESA è ® Install VESA holder (not included in delivery) on TOX UDI Panel. TOX_Manual_TOX UDI Panel_en...
  • Page 37: Software

    The ''Basic settings'' screen appears when the entry ''Basic settings'' is se- lected in the main menu under Settings. Fig. 10 Basic settings screen Button Function Operating system Opens the settings menu of the operating system ® after the restart of the TOX UDI Panel. TOX_Manual_TOX UDI Panel_en...
  • Page 38: Operating System Settings

    Operating system settings Assign host name ® If more than one TOX UDI Panel is used in the network, it is recommend- able to assign a unique name for each device. Factory setting: tox_hmi3 ü The user is logged in with a suitable user level. The necessary write permissions are available.
  • Page 39 Software Network In the ''Network'' menu, the Ethernet IP address can be configured. Interface Meaning ® Machine_net Connection for control system (SCC) of TOX  PRES- SOTECHNIK DHCP-xxxx Connection for customer’s network Defining IP Address by entering a Value ü The user is logged in with a suitable user level. The necessary write permissions are available.
  • Page 40 Software Display The alignment of the touch screen can be changed in menu ''Display''. ü The user is logged in with a suitable user level. The necessary write permissions are available. 1. Tap on Alignment and confirm with OK. 2. Select entry Save and confirm with the OK button. The alignment of the screen is saved.
  • Page 41 To guarantee secure communication we recommend to use an own SSH key. Backup restore ® In menu ''Backup restore'' all settings of the TOX UDI Panel can be stored on a storage medium (e.g. USB stick) and restored again. TOX_Manual_TOX UDI Panel_en...
  • Page 42 Menu Maintenance stick is opened. ® ü USB stick is inserted in the TOX UDI Panel. 1. Select USB stick and press button Select. 2. Follow the instructions on the screen. All necessary files are copied to the USB stick.
  • Page 43 Software Ubiquity ® The TOX UDI Panel can be remote controlled with the aid of the Ubiquity software. Reset identity / Test / Disconnect / State ® This menu may only be used after prior consultation with TOX  PRES- SOTECHNIK.
  • Page 44: Establishing Vnc Connection

    Establishing connection ü ® IP address of the TOX UDI Panel is known. 1. Open the web browser. 2. Enter the address according to the above-mentioned concept. ® Connection to the TOX UDI Panel is being made. TOX_Manual_TOX UDI Panel_en...
  • Page 45: Maintenance

    Maintenance 8 Maintenance 8.1 Requirements for maintenance and cleaning Clean and check the product regularly with regard to material, use and degree of contamination. Suitable cleaning agents are to be used for cleaning: Ÿ Do not use aggressive, and solvent-containing cleaner. The layer can harden and/or the glued cover can come loose.
  • Page 46: Update Tox Software

    ü Necessary authorizations are available. ü ® PC and TOX UDI Panel must be located in the same network. 1. Open the maintenance stick. 2. Start program "Tox-Linux-Filetransfer.exe". ® A window similar to Windows -Explorer opens.
  • Page 47: Disassembly And Disposal

    Disassembly and Disposal 9 Disassembly and Disposal 9.1 Disposal When disposing of packaging, consumables and spare parts, including the machine and its accessories, the relevant national environmental protection regulations must be complied with. TOX_Manual_TOX UDI Panel_en...
  • Page 48 Disassembly and Disposal TOX_Manual_TOX UDI Panel_en...
  • Page 49: Appendices

    Appendices 10 Appendices 10.1 Declaration of conformity TOX_Manual_TOX UDI Panel_en...
  • Page 50 Appendices TOX_Manual_TOX UDI Panel_en...
  • Page 52 Index TOX_Manual_TOX UDI Panel_en...
  • Page 53 Connecting line Hazard potential.......... 15 Technical data ..........  24 Host name Connection Assign ............ 38 Grounding / potential equalization ....  35 Housing cover Housing cover...........  29 Connection .......... 29 TOX® UDI Panel ........ 31 Connections .......... 23 Contact ............ 11 TOX_Manual_TOX UDI Panel_en...
  • Page 54 Index Images Operating system Highlighting .......... 10 Settings ............. 38 Important information ........ 7 operation Information Safe ............ 19 Important.............  7 Organizational measures ....... 13 Installation .............  27 Installation cutout........ 29 Requirement .......... 28 Product overview ........ 20, 22 Safety............ 27 Product overview 10.1 inch...... 20 Set-up location..........
  • Page 55 Connecting line .........  24 Connections.......... 23 Data interface ...........  24 Supply voltage ..........  23 Texts Highlighting .......... 10 Touch screen.......... 22 TOX® UDI Panel Connection.......... 31 TOX®softWare Update ............ 46 Transport ............ 25 types of risks Special ............ 16 Ubiquity Configure ..........
  • Page 56 Index TOX_Manual_TOX UDI Panel_en...