User and maintenance instructions Pump hoist Model 84827*, 400 lb. drum sized, air operated, manually controlled Date of issue July 2022 Form number 403849 Version * Indicates change.
Safety Explanation of signal NOTE* Do not operate equipment without words for safety wearing personal protective gear. Read and carefully observe these installation Wear eye protection. Protective instructions before installing/operating/ equipment such as dust mask, non-skid troubleshooting the assembly. The assembly safety shoes, hard hat, or hearing NOTE must be installed, maintained and repaired...
Installation Specifications Height of unit in lowered position 73 in (1 854 mm) in (2 807 mm) Height of unit in raised position Base casting can be used as a tem plate to Hoist capacity 400 lbs. (181 kg) mark location of anchor bolts. Operating air pressure 40 psi (2,8 bar) minimum, 200 psi (13,7 bar) maximum.
Fig. 2 Kit 2719* For use with PileDriver pumps (refer to application chart) Item Description Pump mounting bracket (refer to chart) Quarter turn valves Air inlet plug Coupling socket Air supply line Base casting Follower * Indicates change. Fig. 3 Mounting template 16 / in (425 mm)
Install follower to Prime pump 4 Shut off valve to lop hoist. 5 Disconnect air coupler to hold hoist in pump tube raised position. 1 Open bleeder plug in pump outlet. 2 Operate pump until material flows from plug opening. To lower pump and follower 3 Shut off pump.
Fig. IPB 1 Kits 1716 and 2716* Before operation, install 243599 fitting into top of pump hoist. Insert 271467 tubing into fitting. Air motor Mounting bracket Note: Kit 1716 consists of 49, 8 and mounting bracket 84391. Kit 2716 consists of 49, 8 and support bracket 84785. Kit 2719 consists of 50, 8 and support bracket 84785.* Indicates change.
Fig. IPB 2 Kit 2719* A−A B−B C−C Before operation, install 243599 fitting into top of pump hoist. Insert 271467 tubing into fitting. Air motor Mounting bracket Note: Refer to service manual - 412843 for low level air cutoff kits. Indicates change.