1. TECHNICAL DATA
Range: 0-10 bar
Power supply: 230V, 50Hz
Protection: IP66
The maximum pump power: 1.5 kW
Maximum temperature: 80 ° C
Warranty: 2 years / 20 million cycles
Upper limit = (H max) / 10 - (0.4 or 0.5)
Installation:
1 If the pump does not have a check valve, pressure switch before you need to install a check valve to prevent
backflow of water that make the switch will not work properly in this case the pump can be switched off
naprzemiennie.2. After unscrewing the tap / valve, if the pump is alternately turned on / off, set a higher value
H.
3. If the pump is still operating despite the closure of the valve, reduce the value H, while if the pump does not
turn, set a higher value L.
2. SETTING THE PARAMETERS
Setting the pressure off - H
Use the buttons (arrow keys) to set a limit, up arrow - to increase, down arrow - to decrease, after setting the
switch to save the settings and automatically switches to the operation mode.
1.
to set a relatively high value H, e.g.,. H5,5
2.
close all valves and check the value on the display, for example. 4.5
3. open the upper valve, and turn on the pump, the pump draws water smoothly, check the value on the
display, for example. 3,5.
4.
This means that the actual value should be 3.5-4.5 H, normally set to a value of 0.3 or 0.4 below the last
proven value in this case is H - 4.1.
5. the maximum operating pressure of the pump is usually (max. Raising / 10) if the pump has a max. 32m
lifting H value should be about - 2.6.
Setting the pressure switch - L
1.
Pressure off L1.2 or 1.5 should be adequate in most cases, if the pump starts when you turn on the tap,
without having to change.
2.
if the pump does not start when you turn on the tap, increase the value of L to the launch of the pump.
3.
When the valve is closed the pump will stop, check the constant display np.2.2, then remove the faucet
and check the displayed value prior to the start of the pump, np.1.2, then set L of 1.2 - 2.2, eg. 1.5
3. INSTALLATION
1. if you are using a circulating pump, install a valve in order to use the switch.
USER MANUAL
SMART PRESSURE SWITCH TO PUMP
DIGIBO 1
Table 1. Recommended settings depending on the parameters
Power
max H
128W
25m
250W
32m
370W
35m
550W
40m
750W
55m
pressure off pressure switch
H2.0
L1.0
H2.6
L1.5
H3.0
L1.8
H3.3
L1.8
H4.8
L2.2

Advertisement

loading

Summary of Contents for IBO DIGIBO 1

  • Page 1 USER MANUAL SMART PRESSURE SWITCH TO PUMP DIGIBO 1 1. TECHNICAL DATA Table 1. Recommended settings depending on the parameters Power max H pressure off pressure switch Range: 0-10 bar Power supply: 230V, 50Hz 128W H2.0 L1.0 Protection: IP66 250W H2.6...
  • Page 2 if using a self-suction centrifugal pump valve must be installed at the pump outlet and switch should be installed> 1 m above the valve to the pressure switch was stable. 3. Note if the source water is above the level of the suction nozzle of the pump and the water pump is supplied to gravity, set the pressure switch L, less than 2 bars and is a pump having a low working pressure, in order to prevent frequent on / off switching of the pump which affects its service life.