Purpose of product application The 500 Series sensor (switch) has two switch outputs and one analog output. danger The sensor (switch) can only be used in the specified application range. The temperature range must be within the permissible range. Do not exceed the rated pressure and power load value.
Safety instruction Safety instructions are intended to protect users from dangerous situations and /or prevent material damage. In the operating instructions, the severity of the potential risk can be indicated by the following signal words: danger An imminent danger to the user. Failure to comply may result in fatal injury. warning An identifiable hazard.
Product characteristics The all-metal casing design, with a highlighted LED digital display, enables the product line to be used in a variety of industrial applications. The three-button design and menu make the product more convenient to use, and a variety of connection methods can fully meet various specific installation needs.
Page 5
Install Safety instructions are intended to protect users from dangerous situations and/or prevent material damage. In the operating instructions, the severity of the potential risk can be indicated by the following signal words: caution Vibration and violent vibration must be avoided during transportation. Even if the sensor (switch) housing is not damaged, Internal components can also break down and cause failure.
Panel description SP2 switch signal light Unit indicator light SP1 switch signal light 4 digit LED digital display Down/increase key Up/down key Confirm/exit key Electrical connection ! Wiring must be done by a qualified electrician and the national and international codes for the installation of electrical equipment must be followed.
Page 7
Hold down [+] to restore factory Settings Switch 1 signal: (Factory default is HNO) Hysteresis function: HNO (normally open) /HNC (normally closed) Window function: FNO (normally open) /FNC (normally closed) RS485 communication Hold down [+] or [-] for at least 1s. After 1 second: The setting value can be changed: At the press of a button, the value increases;...
Page 8
Two way switch + one analog NPN(+Analog quantity) PNP(+Analog quantity) 12~30VDC brown brown 12~30VDC white white black black grey grey blue blue One switch + one analog NPN(+Analog quantity) PNP(+Analog quantity) brown 12~30VDC 12~30VDC brown black black white white blue blue Debugging/operation Sensors can only be debugged and operated by authorized personnel.
Page 9
Level 1 menu Alarm value of Switch 1 (Factory default value is 0.2% of the range) Hold down [+] or [-] for at least 1s. After 1 second: The setting value can be changed: At the press of a button, the value increases; Hold the button down and the value will keep changing.
Page 10
Level 2 menu factory data reset Hold down [+] to restore factory Settings Switch 1 signal: (Factory default is HNO) Hysteresis function: HNO (normally open) /HNC (normally closed) Window function: FNO (normally open) /FNC (normally closed) Hold down [+] or [-] for at least 1s. After 1 second: The setting value can be changed: At the press of a button, the value increases;...
Page 11
Hold + or [-] for at least 1s. After 1 second: The setting value can be changed: At the press of a button, the value increases; Hold the button down and the value will keep changing. OUT2's opening delay. (The factory default is 0s) Hold down [+] or [-] for at least 1s.
Page 12
Hold down [+] or [-] for at least 1s. After 1 second: The setting value can be changed: At the press of a button, the value increases; If you hold the button down, the value will keep changing. [d1] : The measured value is updated every 10ms [d2] : The measurement is updated every 100ms [d3] : Update measurement every 600ms Zero excision value (full scale %) (factory default is 0.5)
Page 13
Display menu Level 1 menu The one-circuit switch does not have this function Level 2 menu Display menu www.katusensor.com...
Page 14
No analog model does not have this function Level 2 menu Display menu www.katusensor.com...
Hold down [+] or [-] for at least 1s. After 1 second: The setting value can be changed: At the press of a button, the value increases; Hold the button down and the value will keep changing. Switch point damping/process data flow (IO-Link communication) and display. (Factory default: 0.06) Maintenance/cleaning Hold down [+] or [-] for at least 1s.
Page 16
Katu Electronic (Kunshan)Co.,Ltd. The phone number is 400-150-8815 Website: www.katusensor.com Factory: No.1120 Jinyang East Road, Kunshan City, Suzhou City...