(1) MG44 Wireless Vacuum Gauge
(1) Reversible 1/4" angled (45°) coupler
(2) AA Batteries
(1) Operator's manual
(1) Year limited warranty
Disconnect MG44 from system before applying pressure; pressures above 870 psig (60 bar) can damage the vacuum gauge.
Hand tighten fittings; overtightening may damage seals.
Follow all equipment manufacturer's testing procedures above those in this manual in regards to properly servicing their equipment.
Use the MG44 Wireless Vacuum Gauge to reliably monitor your evacuations in the field. Long range wireless technology sends deep vacuum measurements up to 1000 feet (305 meters) away. View live on your SMANTM manifold, in the Job Link® mobile app, or directly on the MG44.
Save time by wirelessly monitoring your evacuations. Remotely view trending on the Job Link mobile app so you know when an extra nitrogen purge is required, a leak is suspected, or just watch everything pull as planned.
Reduce the misleading nature of dynamic vacuum measurement during pull down by connecting MG44 directly to the system. The reversible angled coupler makes it easy to orient the gauge so that it's out of the way and easy to see.
Select one of three unique views, including a new Rate Meter that provides a great feel and a Bar Graph that has a range up to atmosphere.
Built for demanding field use, the overmolded case resists damage from physical impact and water ingress.
CLEANING: Clean the exterior with a damp cloth. Do not use detergents or solvents.
SENSOR: Clean the sensor on a regular basis to prevent the build up of oils and contaminents.
DO NOT use an object such as a cotton swab to clean the sensor. This may damage the sensor.
BATTERIES: An empty battery icon indicates batteries need to be replaced. When power is too low to operate, "LoBatt" is displayed 5 sec before powering off automatically. You can also monitor battery life in the Job Link app tool manager.
GASKETS: Each end of the coupler is sealed by a black rubber gasket. These may become worn over time due to overtightening or connecting to damaged male fittings.
It's best to avoid using a hose to connect your vacuum gauge to the system. The coupler makes it easy to connect the gauge directly to a service port or valve core removal tool.
Each end has a valve depressor and gasket so you can flip the coupler to best fit the system and your viewing angle. Rotate and tighten each end independently for optimal viewing and control.
Unless muted, each button press triggers a beep. An inactive button press triggers a double beep.
Hold to toggle power. Toggle backlight. Silence alarm.
Hold to enter MENU.
Hold to exit MENU without saving. ENTER selection.
Stop low alarm and start high alarm.
NEXT view.
NEXT menu item or increase value.
Hold to toggle ALARM mode. Silence alarm.
In standard operating mode, the top line shows the live measurement. The bottom line shows one of three selectable views.
Auto Power Off Enabled | |
Battery Level | |
Low Alarm | |
High Alarm | |
Muted | |
Rate (differential per minute) | |
Wireless Enabled (shown at startup) | |
Wireless Disabled (shown at startup) |
Press NEXT to change the content of the bottom line. Each view provides a unique way to monitor your evacuation.
RATE: The running 10-second average of the measurement's change per minute. Negative rates indicate the vacuum is getting deeper.
RATE METER: The graphical representation of the measurement's real-time change per minute. The scale is dynamic (i.e. relative to the measurement) making changes easy to see.
BAR GRAPH: The graphical representation of the measurement. The scale is static and nonlinear for increased resolution at deeper vacuums. Full bars indicates atmospheric pressure.
Every evacuation is different. Some require multiple purges of dry nitrogen, while some take less time than a phone call. Activate alarm mode so you can get other things handled without babysitting your gauge.
Follow recommended evacuation practices from the equipment manufacturer and training. Alarm levels can be adjusted in the menu.
* Hold ALARM to exit alarm mode at any time.
Connector Type: 1/4'' SAE male fitting. Includes reversible 1/4" angled (45°) coupler with Schrader depressors.
Max Pressure: 870 psig (60 bar)
Refresh Rate: 0.5 seconds
Accuracy: ±(5% reading + 5 micron) at 77°F (25°C), 50 to 2000 micron
Measurement Range and Units:
50 to 25000 micronHg (mTorr); 0.05 to 25 mmHg (Torr);
6 to 3333 Pascals; 0.06 to 33.33 mBar
Bar Graph Range: ultimate vacuum to atmospheric pressure
Best Resolution:
1 micronHg(mTorr), below 2000; 0.001 mmHg (Torr), below 2.5;
1 Pascal, below 250; 0.001 mBar, below 2.5;
Battery Type: 2 x AA Alkaline, NEDA 15A, JIS UM3, IEC LR6
Battery Life: 50 hours typical alkaline
Auto Power Off: 15 minutes default (APO adjustable)
Wireless Range: 1000 feet (305 meters) line of sight. Obstructions affect distance.
Radio Frequency: 2.4 GHz
Wireless Device Requirements:
(Latest compatibility and firmware at www.fieldpiece.com)
Job Link® app: BLE 4.0 devices with iOS® 7.0 or Android™ 5.0
SMANTM manifold: Models SM380V/SM480V with latest firmware installed.
Water Resistance: IP54
Operating Environment: 14°F to 122°F (-10°C to 50°C) at <75%RH
Storage Temperature: -4°F to 140°F (-20°C to 60°C) at <80%RH (with batteries removed)
Weight: 0.66 lbs (300 g)
US Patent: www.fieldpiece.com/patents
The settings menu can be entered when in standard operating mode. Selecting a new setting automatically exits the menu. This saves time getting in and out of the menu quickly for your most commonly changed setting (e.g. wireless).
* Hold ENTER to exit the menu without saving.
Start : Enable Wireless (if off )
Stop : Disable Wireless (if on)
Auto Off : Set Auto Off Timer
Units : Set Unit of Measure
Alarm Lo : Set Low Alarm Level
Alarm Hi : Set High Alarm Level
Mute : Enable Speaker (if off )
Unmute : Disable Speaker (if on)
BkLtTime : Set Backlight Timer
Firmware : View and Update Firmware
Restore : Restore Default Settings
Start or stop sending wireless measurements. Live measurements can be sent to SMAN manifold (overrides its internal vacuum gauge), and to the Job Link mobile app for added capabilities such as live trending. Wireless is disabled by default to maximize battery life.
Set the timer for the gauge automatically powering off. The timer is reset when a button is pressed. The timer is disabled in alarm mode. (15min, 30min, 45min, 60min, Disabled)
Set the unit of vacuum measurement. Alarm levels are automatically converted to match the unit setting.
(Microns, Pascals, mBar, mTorr, Torr, mmHg)
Set the vacuum level required to trigger the low alarm. Hold NEXT for quicker scrolling.
(50 - 500 - High Alarm)
Set the vacuum level required to trigger the high alarm. Hold NEXT for quicker scrolling.
(Low Alarm - 1000 - 9000)
Mute or unmute the speaker. Button presses and alarms remain silent if the speaker is muted.
The icon appears if the speaker is muted.
Set the timer for the backlight automatically turning off. The timer is reset when a button is pressed.
(10s, 20s, 1min, 2min, 5min, 10min, 15min, 30min)
Check the firmware version (X.XXX.X) by reading the first 4 digits. If a new version is available from the Job Link mobile app, initiate the update from your mobile device.
To restore all settings to their factory defaults, press NEXT until "YES" is displayed and press ENTER to confirm. To exit without restoring, select "no" or hold ENTER.
EN 300 328
2ALHR003
00263-18-10972
IC: Industry Canada
22518-BT003
Regulatory Compliance Mark
Waste Electrical and Electronic Equipment
Restriction of Hazardous Substances Compliant
IFETEL: Federal Telecom Institute
RCPFI2A18-0235
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This product is warranted against defects in material and workmanship for one year from date of purchase from an authorized Fieldpiece dealer. Fieldpiece will replace or repair the defective unit, at its option, subject to verification of the defect.
For international customers, warranty for products purchased outside of the U.S. should be handled through local distributors. Visit our website to find your local distributor.
© Fieldpiece Instruments, Inc 2021