Read the manual carefully before installing and using of the fan. Caution! Make sure that there are no visual defects when unpacking the fan.
We do recommend you to save the bill of purchase with stamped guarantee coupon, for the purpose of possible reclamation. Otherwise guarantee will be not in legal force.
Before connecting to the mains supply ensure that mains voltage (V) and frequency (Hz) corresponds to the parameters on the rating plate inside the cooker hood. Caution! This device may be used by children starting from age of 8 as well as people with physical or mental disorders, given that they are familiar with the manual and safety provisions in respect to this device. It is prohibited for children to play with the device. Children may not carry out maintenance or cleaning of this device without supervision of adults.
This device may be used by children starting from age of 8 as well as people with physical or mental disorders, given that they are familiar with the manual and safety provisions in respect to this device. It is prohibited for children to play with the device. Children may not carry out maintenance or cleaning of this device without supervision of adults.
L100 | L125 | L150 | |
Technical information | |||
Voltage (V) | 230 | ||
Phase (Hz) | 50 | ||
Power (W) | 15 | 16 | 20 |
Suction power (m3/h) | 75 | 120 | 190 |
Noise level (dB) | 32 | 36 | 40 |
Protection against environmental factor | IPX4 | ||
RPM | 2550 | 2360 | 2100 |
Ambient temperature | -250 ... +400 | ||
Weight (kg) | 0,35 | 0,37 | 0,47 |
Before installation, disconnect the power network where you are planning on installing the fan.
Installation may be carried out only by a qualified electrician.
Fan is installed on a ventilation duct by fixing it to the wall by screws (Fig. 1).
Fig. 1
Base model fans, fans with a switch (W), fans with a timer (T), and fans with a humidity sensor (H) shall be connected to the power network. In order to do that, remove the lid by twisting it counter clockwise (Fig. 2).
Fig. 2
Under the lid, there is either NL or SNL terminal that shall be connected to the power network in accordance with the connection diagrams (Fig. 3 - 5).
Fig. 3, 4, 5
Fans with a cable (P), fans with a switch and cable (WP), fans with a timer, switch, and cable (TWP), and fans with a humidity sensor, switch and cable (HWP) shall be connected to a power outlet.
The fan that is equipped with a pull-down switch is turned on and off by pulling down the string that is located on the bottom of the fan.
Cable powered fan is equipped with a 1.9 m long cable that may be connected to a power outlet.
A fan that is equipped with a pull-down switch and cable shall be connoted to a power outlet. The fan is turned on and off by pulling down the string that is located on the bottom of the fan.
The fan is turned on by the S1 power switch (Fig. 4) or by turning on the light (Fig. 5). After turning off the light or the switch, the fan continues its operation for a specific time interval that is set up by a controller. This interval may be 0 to 30 minutes long.
The fan is equipped with a humidity level control that may be used to set the level of humidity from 50%RH - 90%RH and a delay control that may be used to set the delay from 0 to 30 min. The fan is turned on automatically when a certain humidity level is reached in the room or it may be turned on manually by a switch. Connection diagram is shown in Fig. 3. The fan is turned off after a pre-set time interval. Humidity and delay controllers are located on the control unit (Fig. 7).
Fig. 6, 7
Sizes, mm | L100 | L125 | L150 |
A | 120 | 145 | 170 |
B | 120 | 145 | 170 |
C | 70 | 70 | 70 |
D | 98 | 123 | 148 |
E | 20 | 20 | 20 |
When connecting the fan to the power network, set the right-side controller to "0 min" and the left-side controller to "Low Level of Humidity". With these settings the fan should work without stopping. The following steps shall be carried out in order to specify the humidity level that triggers the fan:
A fan that is equipped with a timer, cable, and switch is turned on by a pull-down switch. It will turn off after the present time interval by pulling down the string at the bottom of the fan once more. To adjust the timer, see section "Timer T".
A fan that is equipped with a humidity sensor, cable, and switch is turned on by a pull-down switch or after a certain humidity level is reached in the room. It turns on after the pre-set time interval by pulling down the string on the bottom of the fan once more or if humidity in the room drops to a certain level. To adjust the humidity sensor, see section "Humidity Sensor H".
Fans with electronic control unit must be adjusted before they are connected to the power network.
If the potentiometer is set to "0 min", the fan will turn on for a couple of seconds after connected it to the power network.
Producer guarantee is 24 months.
In the case of damages contact the place of trade.
The guarantee does not cover:
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.