Page 1
Note Before you begin, complete the software and hardware installation procedures applicable to your application. Note the guidelines in this document are specific to the YAV90060 . The other components in the system might not meet the same safety ratings. Refer to the documentation of each component in the system to determine the safety and EMC ratings for the entire system.
ELECTROMAGNETIC COMPATIBILITY GUIDELINES The product YAV90060 to which this manual relates meet the provisions of the EU Directives 2014/30/CE which declares the compliance of electromagnetic compatibility (EMC) and directive 2014/35/CE of low voltages electronic devices.
• One 8 x 16 Matrix • One 4 x 32 Matrix Joining two or more YAV90060 modules, the matrix can be increased until all test requirements are covered. LAYOUT AND DIMENSIONS All dimensions are in millimetres. Pag 4 | 16 www.6tlengineering.com...
RESET Must be OPEN on operation. A temporary bridge causes a reset of the board. CAN-END Placing jumper adds a 120 Ohm resistor between the CAN-High and CAN-Low signals of CAN-Bus. Switches description Pag 8 | 16 www.6tlengineering.com 24/06/2022 YAV90060...
Units • Maximum switching voltage • Rated current • Switching power 62.5 • Minimum switching voltage • Operate time • Release time • Bounce time • mΩ Initial contact resistance Relay contact specifications Pag 9 | 16 www.6tlengineering.com 24/06/2022 YAV90060...
11. OPERATION Through the PHI6 Explorer soft panel the user can interface with the YAV90060 board manually. This tool is a very useful for table-top debugging of test-systems or system maintenance on-site. The image show configuration as dual 4x16 Pag 10 | 16 www.6tlengineering.com...
Page 11
Configuring matrix Select the required matrix structure: Two independent double pole 4 x 16 Double pole 4 x 32 Double pole 8 x 16 Configuration 4 x 32 Configuration 8 x 16 Pag 11 | 16 www.6tlengineering.com 24/06/2022 YAV90060...
Page 12
By clicking this button, the panel will change its background color from grey to yellow, and we will be able to change tags. Exit Click this button to exit the Phi6 panel. Pag 12 | 16 www.6tlengineering.com 24/06/2022 YAV90060...
Operation in mode 1 keep isolated the two matrix and all the column and row tags are available to be written. Operation in mode 2 will keep hidden the blocks column unions and the low row tags Pag 13 | 16 www.6tlengineering.com 24/06/2022 YAV90060...
For a more efficient matrix application, do not use the Y connections, just the X-axis. The number of X access points will define the matrix dimensions and columns, and the Y will be determined by the quantity of simultaneous connections. Pag 14 | 16 www.6tlengineering.com 24/06/2022 YAV90060...
To start using the product just remove vacuum bag carefully to avoid damage. To install the YAV90060 simply insert the module on a VPC receiver, vertical or horizontally, according to the Receiver arrangement. Once it is completely inserted, fix YAV Pag 15 | 16 www.6tlengineering.com...
Page 16
4-40 UNC screws on each side of connector. Tight them using a 3/32 Allen wrench at full revolutions. Torque should be 0.45Nm max. Finally, connect the X1 rear plug of CAN bus and power supply (24VDC) to start using the module. Pag 16 | 16 www.6tlengineering.com 24/06/2022 YAV90060...