Manual and Automatic Modes Manual Mode Automatic Mode Pre-infusion options Brew options UI Display Display Modes Brew Display Data Table Table of data shown in different phases and modes. Screen Examples 2023 Mavam User Manual V4.53 UC/F Page 2 of 28...
Page 3
Menu Item 7, 8, Setting Automatic Pre-Infusion and Brew Time:2 NOTE: This manual is for the daily use of the machine. For detailed data, technical diagrams, installation, and troubleshooting please see the applicable document. 2023 Mavam User Manual V4.53 UC/F Page 3 of 28...
2021 Safety Warnings Safety Messages IMPORTANT Information for the Mavam Undercounter Espresso Machine ➔ DISCONNECT FROM ALL POWER SOURCES BEFORE SERVICING ➔ Read the entire manual BEFORE operating this machine ➔ Steam and condensation from the steam wand discharge is HOT and may cause burns ➔...
0 to 120 seconds (2 minutes) Steam Time 0 to 120 seconds (2 minutes) Water Time 0 to 30 seconds (½ minute) Internal Boiler Unit Temperature 80 C (175 F) 2023 Mavam User Manual V4.53 UC/F Page 5 of 28...
Overview Machine Description The Mavam Under Counter Espresso Machine is a commercial espresso machine featuring a unique user interface that sits flush with the counter. Depending on model there may be one, two, or three group heads, one or two steam wands, one hot water jet, and one or two pitcher rinsers built into the drain tray.
2021 Description of terms The following terms are used throughout this manual and other Mavam publications. While not a full list these are the most used and common terms. Blind Basket: A cup that is installed in the portafilter without holes. This is used for cleaning the Group Head.
* We acknowledge that to make a perfect shot requires the full attention of a dedicated and skilled barista! We aim to get close to that when full attention can not be given. 2023 Mavam User Manual V4.53 UC/F Page 8 of 28...
2021 Machine Components There are two categories of components, Main, and Group. Main components are the core parts of the Mavam Espresso machine regardless of the number of groups. Group components are the parts required for one group. Main Components Boiler Unit: This contains the steam / hot water boiler, Pump power connections, Water distribution manifold, BCU, and 24V Power supply.
Placement on User Interface UI Actuators control all the functions of the UI. They consist of an actuator, (the part you push), and an illuminated ring that indicates mode of operation. 2023 Mavam User Manual V4.53 UC/F Page 10 of 28...
Each actuator has two uses, regular operation, and menu (setting options for that group). Uses of the actuator are detailed in the “Functions” section. 2023 Mavam User Manual V4.53 UC/F Page 11 of 28...
The numbers are the firmware version number. The two letters are the configuration. There are two configuration options: [C/U] and [F]. [C] is for MACH 2 above counter units, [U] is Undercounter units. [F] is for flow meter equipped units.
Brew cycle is started. Hot water under pressure is forced through the coffee to produce espresso. Mavam gives the barista complete control over the time, pressure, and temperature the coffee is extracted at. How to change these settings is beyond the scope of this document, please refer to the appropriate instructions on how to change these settings.
3. When running pressing either Pre-Infusion or Brew actuator at any time will cancel the clean cycle. 4. When completed, or stopped, the UI will return to Idle mode. Clean Cycle running Clean Cycle running, Display between cycles 2023 Mavam User Manual V4.53 UC/F Page 14 of 28...
“AUTO:1”, or “AUTO:2” The cycle may be stopped anytime by pressing the current phase actuator. For example, if in the Pre-Infusion phase, pressing the Pre-Infusion actuator will cancel the cycle. 2023 Mavam User Manual V4.53 UC/F Page 15 of 28...
There is one display per group. The display is located in the front of the UI, (closest to the barista), and centered on the group. Placement of Display on User Interface 2023 Mavam User Manual V4.53 UC/F Page 16 of 28...
M, A M, A Pre-Infusion M, A Brew Post Brew Menu M = Shown in Manual Mode, A = Shown in Automatic Mode, X = Not Displayed, S = Special use 2023 Mavam User Manual V4.53 UC/F Page 17 of 28...
Screen above indicates that AUTO 1 is Pre-Infusion fifteen seconds, Brew 300 Pulses. AUTO 2 is Pre-Infusion BEST, Brew 350 Pulses. Menu functions and screens are covered in “USER INTERFACE MENU INSTRUCTIONS” 2023 Mavam User Manual V4.53 UC/F Page 18 of 28...
3. Volume used during Pre-infusion 4. Volume used so far in Brew 5. Time so far in Brew The shot information will remain on screen for 30 seconds before going to Idle. 2023 Mavam User Manual V4.53 UC/F Page 19 of 28...
The Steam AND / OR Water Actuator is used as an Enter button. On three group machines the Water actuator is used for the center User Interface Enter button. For ease of display the Steam Actuator is shown in all illustrations. 2023 Mavam User Manual V4.53 UC/F Page 20 of 28...
Steam or Water actuator to start the clean cycle. If you do not want to perform the clean function leave at “NO” and press the Steam or Water actuator to move to the next menu. Menu item 1. Auto Clean Cycle. 2023 Mavam User Manual V4.53 UC/F Page 21 of 28...
Page 22
2021 Example screens when Auto Clean has been selected and run Auto Clean Running Auto Clean between cycles 2023 Mavam User Manual V4.53 UC/F Page 22 of 28...
[0.0]and temperature reads 96.2. Using a test instrument temperature has been measured to be 96.0, Offset is changed to [-0.2]. This is subtracted from the sensor input and displayed temperature is now 96.0 (screen at right). 2023 Mavam User Manual V4.53 UC/F Page 23 of 28...
Change modes between Manual and Automatic. Mode is displayed in the upper data window. Pressing the Pre-Infusion actuator changes mode to Automatic, pressing the Brew actuator changes to Manual. Pressing Steam or Water applies the selection. Menu Item 4, Manual / Automatic 2023 Mavam User Manual V4.53 UC/F Page 24 of 28...
Decreasing TIME past 1 will select BEST, down one more will select OFF. Once set to the desired mode pressing Enter will save the setting and move to Item 6. 2023 Mavam User Manual V4.53 UC/F Page 25 of 28...
NOTE: After no activity for thirty seconds the Menu will exit and return to the Idle screen. If you have entered a setting or do not wish to record that setting just let the menu sit idle and it will exit without saving that setting. 2023 Mavam User Manual V4.53 UC/F Page 26 of 28...
Page 27
2021 This page left blank 2023 Mavam User Manual V4.53 UC/F Page 27 of 28...
Page 28
2021 2023 Mavam User Manual V4.53 UC/F Page 28 of 28...
Need help?
Do you have a question about the UnderCounter and is the answer not in the manual?
Questions and answers