Summary of Contents for Pelltech DK8002A1

  • Page 1 Boiler controller Instruction manual DK8002A1...
  • Page 2: Table Of Contents

    4.3 Software.............................7 4.4 Other..............................8 5 Burners log..............................8 6 Water.................................9 6.1 Boiler..............................9 6.2 Cirquit 1 ja Cirquit 2 (Heating cirquits)....................10 6.2.1 Graph (Heating graph).......................10 7 Pellet container (Fuel)..........................11 8 Fire................................11 9 House (Room heating)..........................12 9.1 Heating plan............................12 10 Screen calibration..........................13 DK8002A1 www.pelltech.eu...
  • Page 3: Introduction

    Boiler controller EP0012 is meant to be used as an electronic thermostat, boiler cleaning controller and heating controller through two 3T valve motors with all burners manufactured by Pelltech OÜ. It has 7 resistive inputs for measuring different temperatures, two outputs for 3T valve motors, four 230V 5A outputs , one Lambda (O )input and one ultrasonic (ULTRASONIC) input for extra modules.
  • Page 4: Settings

    4/13 Settings In boiler controller settings menu, you can configure boilers inputs and outputs, update controllers and burners software and change other settings. To enter a menu, just press on the appropriate area on the touchscreen. 4.1 Inputs DK8002A1 www.pelltech.eu...
  • Page 5: External Module Configuring

    (ULTRASONIC). Only 1k NTC and PT1000 sensors are compatible with controller, other sensors won’t work. For oxygen sensor, only Pelltech’s EP0022 can be used. Each input has to be connected to a function to be usable. For example, input IN7 is connected with Boiler function to be used as boiler temperature input.
  • Page 6: Outputs

    Sensor – Sensor, which temperature is used to control the relay. • Type – Type of control, that is used for switching the relay. For example threshold. • Zone - Temperature or time zone that is used in controlling the relay. DK8002A1 www.pelltech.eu...
  • Page 7: Software

    On the first row is displayed the current version, on the second row is displayed new or backup version, depending on are you trying to update or to go back to an older version. Pushing on the third row starts the update process. DK8002A1 www.pelltech.eu...
  • Page 8: Other

    Current state is marked with the prefix “CUR” (Current) and its current time can be seen in the column on the right. Arrows in the lower part of the screen can be used to move around in the log. DK8002A1 www.pelltech.eu...
  • Page 9: Water

    The boilers thermostat will be turned on when the temperature of the boiler has dropped below setpoint – hysteresis level and turned off, when the temperature has risen above setpoint + hysteresis. DK8002A1 www.pelltech.eu...
  • Page 10: Cirquit 1 Ja Cirquit 2 (Heating Cirquits)

    Configurations made earlier are saved until the next changes to the graph are made. DK8002A1 www.pelltech.eu...
  • Page 11: Pellet Container (Fuel)

    In menu “Fan” it is possible to observe fans speed and change their parameters. • In menu “Cleaning” it is possible to change parameters related to cleaning. The on/off button in the lower tight corner is used to turn the burner on and off. DK8002A1 www.pelltech.eu...
  • Page 12: House (Room Heating)

    • Away - Constant temperature is kept in rooms until the given time, after what heating by the schedule will be restored. • Manual – Constant temperature will be hold for given hours. 9.1 Heating plan DK8002A1 www.pelltech.eu...
  • Page 13: Screen Calibration

    (There should appear three dots on different parts of the screen). You have 8 seconds to push each calibration dot, waiting too long will restart the controller. After pressing the last dot, the device returns to Main screen and the screen should be calibrated. DK8002A1 www.pelltech.eu...