Product Specifications - Sentry ST313A Instruction Manual

Combustible gas detector
Table of Contents

Advertisement

3. Product Specifications

Model
Sensor
Detection Gases
Sensitivity levels
Calibration
Response time
Warm up time
Battery type
Battery life
Sensor failure
notification
Audio alarm
Auto power off
Low battery
indicator
Tip light
Flexible probe
length
Operating temp.
and %RH
Storage temp.
and %RH
Dimensions
Weight
Accessories
ST313A
Semiconductor
Methane, Propane, Butane, and other
hydrocarbons gases
High : 10PPM
Medium : 30PPM
Low : 100PPM
Manually reset to background level
Less than 0.5 second
Approx. 50 seconds
3.7V DC, 1960mAh rechargeable
lithium battery
Max. up to10 hours continuous use
after fully charged.
Yes
Yes(Buzzer)
10 minutes of idle.
Yes (Battery Icon)
Yes
18" (450mm)
32°F ~ 122°F(0°C ~ 50°C), <80%RH
14°F ~ 140°F(-10°C ~ 60°C), <70%RH
7.2"x 2.8"x 1.6" (184 x 70 x 40 mm)
12 oz.(340g)
Included: Quick user's guide, USB
cable, Leak test bottle
Option to buy: Charger, Rubber
protector, Hard carrying case.
4