EMG DELTA VFD-MS300 Series Quick Setup Instructions

EMG DELTA VFD-MS300 Series Quick Setup Instructions

Variable speed drive 1 phase to 3 phase

Advertisement

Quick Links

Connect Phase (Live) to R and Neutral to S for single
phase supply
Connection U/T1, V/T2, W/T3 go to the motor
Connect 3 phase input supply L1/R, L2/S, L3/T
Connection U/T1, V/T2, W/T3 go to the motor
Instructions for Remote Setup
(Remote On/Off and Speed Variation)
For remote stop and start connect between DCM and
MI1 (FWD) and MI2 (REV) (DCM is your common)
For remote Potentiometer connect the potentiometer
to +10V, AVI and ACM (common).
Set 00.20 to 2 (Remote Potentiometer setting)
Set 00.21 to 1 (Remote ON/OFF setting)
Set 02.00 to 1 or 2 (2-wire operation control)
• Set 02.00 to 3 (3-wire operation control)
V/F curve set up
(Factory setting is General purpose)
QUICK SETUP INSTRUCTIONS FOR
VARIABLE SPEED DRIVE
1 PHASE TO 3 PHASE
AND
3 PHASE TO 3 PHASE
VFD-MS300 Series
HAMILTON PH: 07 847 3374
CHRISTCHURCH PH:03 666 3374
sales@rotatingmachinery.co.nz
AUCKLAND PH: 09 271 6063
info@brookmtl.co.nz

Advertisement

loading

Summary of Contents for EMG DELTA VFD-MS300 Series

  • Page 1 Instructions for Remote Setup (Remote On/Off and Speed Variation) • For remote stop and start connect between DCM and MI1 (FWD) and MI2 (REV) (DCM is your common) • For remote Potentiometer connect the potentiometer QUICK SETUP INSTRUCTIONS FOR to +10V, AVI and ACM (common). VARIABLE SPEED DRIVE •...
  • Page 2 Quick Setup for Variable Speed Drive List of quick set up parameters Important Notice Turn on power to unit and follow as below: • • Wiring and connection must be carried out by a 00.02 All parameters are reset to factory settings or 50Hz settings, set to 9 (must be none after initial powerup) registered electrician.