7. Easy Sensor Calibration M ethods and Action Points
Step
1
Place Guide-Roller and Cooking Tray in the Cavity.
2
Put Calibration-Jig on the Tray center.
3
Press Easy senstor Pow er Level for 2 seconds.
4
Calibration result(Hexadecimal 4 digits)w ill
be displayed after sensing for 16 seconds.
(* Calibration Jig : IEC 1000cc Beaker
Calibration M ethods and Action Points
7-1
Error Code
E2 E2 E2
E2
E3
E4
E5
Easy Sensor Voltage Check
7-2
Step
1
Put Inspection - 200cc A cup of w ater on the Tray center.
2
Operate M WO.
3
Press Easy Sensor Clock Button for 2 seconds.
4
Esay sensor value(Hexadecimal) w ill be displayed.
* If sensing valeue is less them (or equal) to 15(Hexadecimal), repeat 2~3times from
step 1 to step 4 until display show s more than 16(Hexadecimal).
If you fail to have more than 16(hexadecimal), replace Ass'y Sensor PCB or M agnetron.
Then;
-. Leave unit in room temperature about 20 minutes for cooling.
-. Calibrate Easy Sensor from the beginning step of calibration method.
-. Check Easy Sensor Voltage again.
Samsung Electronics
Activities
Weater 1000cc
Reason
Door open or Cancel pad pressed
during Calibration.
No Pow er.
Wiring problem for the sensor.
Sensor PCB damaged.
Sensor PCB failure.
M ain PCB failure.
Sensing voltage problem due to
w rong parts fitted on the PCB.
Low pow er.
standard load not used during
calibration.
EEPROM Short or Open on the
main PCB.
Activities
Calibration Button
Remarks
Do not open Door/ press Cancel
pad during calibration.
Replace Defect Components.
Check w iring.
Repleace Sensor PCB.
Repleace Sensor PCB.
Repleace M ain PCB.
Replace Sensor PCB.
Repleace M agnetron.
Only use standard load.
- 0.7 : 1000cc in IEC beaker
- 1.0 : 500cc in normal 600cc beaker
Repleace M ain PCB.