Do you have a question about the BCR-S Mini G2 and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Integra BCR-S Mini G2
Page 1
Access Control – and Security Management System Installation manual BCR-S Mini G2 1-981-2181-GB, 2021-03-16 BCR-S Mini G2 Page 1 SystemHouse Solutions...
Page 2
All product names and trademarks mentioned in this document belong to their respective owners. 1-981-2181-GB, 2021-03-16 BCR-S Mini G2 Page 2 SystemHouse Solutions...
Drilling pattern 1 pcs Opening Tool xCR-SD/S-Mini G2 1 pcs Not supplied Instructions for other devices that will be connected to the BCR-S Mini G2. Technical specifications Power supply Typical/Min/Max 24V DC/20VDC/30VDC Power consumption Typical/Max at 24V 20 mA/25 mA...
Reader must be disconnected from voltage before installation and service. • Do not modify any components or part of device. • All reparation should be performed only by the manufacturer. 1-981-2181-GB, 2021-03-16 BCR-S Mini G2 Page: 6 SystemHouse Solutions...
Route cables to other accessories to be connected. Install the bottom part of BCR-S Mini G2 box to the wall. Feed all cables inside the box to appropriate position and fix them to the box with cable ties.
Quick installation guide in this document. Opening tool: Maximum torque for box installation When device is installed by using an electrical screwdriver the maximum torque used shall be 2.5 N/m. 1-981-2181-GB, 2021-03-16 BCR-S Mini G2 Page: 9 SystemHouse Solutions...
Power Supply BCR-S Mini G2 doesn’t use own power supply instead it is powered from S-Node G2, central unit C- Node G2, Moveo or Moveo XL. The S-Node G2 is normally powered from central unit C-Node G2 where power supply and communication line are distributed together to door environments.
5.1.1 Address setting on reader To set address on BCR-S Mini G2 you need to use BCR-G2 Setup program. Valid address range when connected to S-Node G2: 1-2 Valid address range when connected directly to C-Node G2/Moveo/XL: is 1-8 Procedure to setup address: 1.
Page 13
6. The connection button will change color to red – disconnect since it lost connection to reader with previous address. 7. To test that reader has proper address change Address to new Address and press Connect. You should now get Disconnect with green color. 1-981-2181-GB, 2021-03-16 BCR-S Mini G2 Page: 13 SystemHouse Solutions...
If there are any problems connecting to reader, make sure you have correct address set in settings and that tamper switches is not active. Make sure that you have correct addresses set in Integra Client. RS485 communication line The RS485 bus must be configured as a bus with no branches. The bus needs to be terminated at each end.
Always use twisted pair cables, and we always recommend the use of shielded cable for connecting card readers. NOTE: ALWAYS calculate total power consumption and choose a cable with conductor cross-sectional area designed for that total power consumption. ALWAYS calculate voltage drop before selecting cable. 1-981-2181-GB, 2021-03-16 BCR-S Mini G2 Page: 16 SystemHouse Solutions...
This can be done by using two cable pairs for the bus, "RS485 out" and "RS485 in". C-Node G2 can be equipped with an optional connection block for this, CG2-VDE 1-981-2181-GB, 2021-03-16 BCR-S Mini G2 Page: 17 SystemHouse Solutions...
In this case bottom part must be exchanged. • Measure voltage on screw terminal and compare it against level on used power supply. Voltage must be within range 20-30 V DC. 1-981-2181-GB, 2021-03-16 BCR-S Mini G2 Page: 18 SystemHouse Solutions...
2. Check power supply if it’s within range 20-30 V DC. 3. Check setting of switch SW1 – termination of RS485 according position of reader on the line. 4. Check setting inside system if device has proper address set. 1-981-2181-GB, 2021-03-16 BCR-S Mini G2 Page: 19 SystemHouse Solutions...
The Card Reader is used for contactless smart card access cards in a 30 mm range, status indications of the door environment. LED’s for indication of door status, etc. Built in buzzer for warning and button press indication etc. 1-981-2181-GB, 2021-03-16 BCR-S Mini G2 Page: 20 SystemHouse Solutions...
Updated document with latest pictures, corrected data regarding Mini version. 2019-01-22 Added description about installation on metal surfaces. 2020-01-02 Updated with new logos and company name 2021-01-25 Accessories types updated, added dimensions 1-981-2181-GB, 2021-03-16 BCR-S Mini G2 Page: 23 SystemHouse Solutions...
Need help?
Do you have a question about the BCR-S Mini G2 and is the answer not in the manual?
Questions and answers