iMAGI+
v.201808
USER MANUAL
Premium & Sérénité

Advertisement

Table of Contents
loading

Summary of Contents for Magiline iMAGI+ Premium

  • Page 1 iMAGI+ v.201808 USER MANUAL Premium & Sérénité...
  • Page 3: Table Of Contents

    CONTENT I. iMAGI Interface .....................................5 II. Turning on the cabinet..................................5 III. Main Menu ......................................6 1. Ergonomics of the main menu ..............................6 2. iMAGI control panel action icon ..............................6 3. Menu P1/3 ......................................7 4. Menu P2/3 ......................................7 5. Menu P3/3 ......................................7 IV.
  • Page 4 Dear customer, You have trusted Piscines MAGILINE for your iMAGI Premium+ or Sérénité+ pool and we thank you for this. Your iMAGI pool is equipped as standard with the iMAGI box which allows you to control your pool with your fingertips wherever you are in the world.
  • Page 5: Imagi Interface

    It is strongly recommended to check the operation of this differential switch at least once at the beginning of each season. Simply press the T» test button. The differential switch should then open and turn off the power to your cabinet.» v.201808 www.magiline.fr...
  • Page 6: Main Menu

    When there is one or more errors concerning iMAGI, it will result in the appearance of a triangle. Pressing this key allows you to know the nature of the error. Touch the grey area under the alarm to reset it. www.magiline.fr v.201808...
  • Page 7: Menu P1/3

    (not available when a treatment system is declared in your iMAGI control panel but the Water Treatment» icon appears) Accessory2 (see p17) (see p12) Installer (acces with code) (see p27) System Wintering 5. MENU P3/3 (see p26) (see p15) v.201808 www.magiline.fr...
  • Page 8: Filtration

    First filtration cycle Second filtration cycle First filtration cycle Second filtration cycle Start time: 9H00 Start time: 14h30 Start time: 10H00 Start time: 14h30 End: 12H00 End: 18h30 End: 13h00 End: 18h30 Total : 7h Total : 8h www.magiline.fr v.201808...
  • Page 9: Adjustable Mode (Can Be Set By User)

    It is preferable that both time periods be set to the same start time for the morning. After setting the exact time, press the execute button to confirm your choice or press the cancel button cancel and return to the previous menu. v.201808 www.magiline.fr...
  • Page 10: Heating

    NB: If your box is connected to the internet, this mode is not useful. If you have chosen auto mode, your heating system will automatically switch to eco mode during pre-programmed periods. To program schedules, press the key to select the period or periods you can modify. www.magiline.fr v.201808...
  • Page 11: Choice Of Heating Operation Mode

    It is possible that this mode will trigger the filtration pump 4 minutes every hour to control the pond temperature and will stop at set times beyond the filtration hours. v.201808 www.magiline.fr...
  • Page 12: Neolight Projector & Accessories 1, 2, 3, 4

    VII. MAGIsport2 (optional) This menu allows you to turn your MAGIsport2 Counter-Current Swim on or off. After pressing the ON key, your MAGIsport2 Counter-Current Swim will remain in operation until the 20-minute delay expires or the OFF key is pressed. www.magiline.fr v.201808...
  • Page 13: Bathing

    User manual VII. BATHING To enable you to maintain perfect water quality, even when your pool is heavily used, Piscines MAGILINE has integrated a timed swimming mode into your iMAGI control panel. Swim mode allows you to easily activate your filtration and automatic treatment (if installed) during a 2H period when filtration is paused to treat and filter your water when bathers enjoy your pool.
  • Page 14: Internet (If Enabled)

    User manual X. INTERNET (if enabled) This menu allows you to know the connectivity settings of your iMAGI control panel so that your Piscines MAGILINE installer can create your customer space on www.imagi.fr. When the connection is active and working, the two small screens at the bottom right flash alternately green and red, and a countdown is made from 0 to 5.
  • Page 15: Overwintering (If Enabled)

    - Press the - key to decrease the setpoint Switching on the filter pump : Temperatures and times can be set by the user The minimum filtration time is limited to 10 minutes at 0°C. The minimum filtration time is limited to 20 minutes at -10°C. v.201808 www.magiline.fr...
  • Page 16: Ph Sensor (Imagi Premium+)

    • Soak the probe in 2.6% (commercial) bleach for 1 hour to remove organic matter. • Rinse the probe well with clean water • Store it in its case, with saturated potassium chloride (KCL). A few ml is enough (Pharmacy) Regenerates your probe www.magiline.fr v.201808...
  • Page 17: Treatments (Imagi Serenity)

    If you see this information it is because there is a lack of water flow in the analysis chamber. Possible causes are: • Switching off the filter pump • Incorrect adjustment of the float in the analysis chamber • The wrong by-pass setting • Clogged cartridge • Suction strainer clogged v.201808 www.magiline.fr...
  • Page 18: The Different Treatments

    • SÉRÉNITÉ O2 • SÉRÉNITÉ PRO + • PREMIUM + 1. REDOX SERENITY: PH AND LIQUID CHLORINE TREATMENT Treatment box Redox Probe pH sensor Analysis chamber Dosing pump Dosing pump (peristaltic) (peristaltic) New version of the analysis chamber from 2018. www.magiline.fr v.201808...
  • Page 19 Chlorine • The treatments must be in ON mode for The whole thing to work (but everything is already set at The factory) • To calibrate The probes go to PROBE CALIBRATION and follow The steps requested. v.201808 www.magiline.fr...
  • Page 20: Sel Serenity: Ph Treatment And Electrolyser

    User manual 2. SEL SERENITY: PH TREATMENT AND ELECTROLYSER Treatment box Redox Probe pH sensor Analysis chamber Dosing pump (peristaltic) Electrolyser The possible settings for a SEL Serenity treatment are the same as for the REDOX Serenity treatment.. www.magiline.fr v.201808...
  • Page 21: Serenity O² : Ph And Active Oxygen Treatment

    The pH treatment • Press right to set Active Oxygen treatment • to calibrate The probes go to calibrate The probe and follow The requested steps. Paramètre pH et Oxygène actif • ON processing to make it work v.201808 www.magiline.fr...
  • Page 22 2570 1285 857 342 514 428 367 321 286 257 234 214 198 184 171 161 151 143 135 128 122 117 112 107 Dosing time in seconds per filter hour Example: For a swimming pool of 10 m , for 8 hours of filtration per day, the active oxygen must therefore be set to 21 seconds of injection per hour. www.magiline.fr v.201808...
  • Page 23: Serenity Pro + : Ph And Liquid Chlorine Treatment

    User manual 4. SERENITY PRO + : PH AND LIQUID CHLORINE TREATMENT Treatment box Redox Probe pH sensor Analysis chamber Dosing pump Dosing pump (peristaltic) (peristaltic) v.201808 www.magiline.fr...
  • Page 24 Chlorine • The treatments must be in ON mode for The whole thing to work (but everything is already set at The factory) • To calibrate The probes go to PROBE CALIBRATION and follow The steps requested. www.magiline.fr v.201808...
  • Page 25: Interpretation Of The Different Treatment States

    Double junction pH pH probe FOI0027XX Calibration Remplacement probe Amperometric chlorine FOI00120XX Replacement if probe membrane Amperometric Mandatory semi public and probe Replacement public use FOI00121XX Electrolyte recharge Double junction ORP Redox probe FOI00032XX Calibration Remplacement probe v.201808 www.magiline.fr...
  • Page 26: System

    Pressing this key decreases the time Pressing this key decreases the minutes After making changes in this menu, press the execute key to confirm your choice or the cancel key to cancel and return to the previous menu. www.magiline.fr v.201808...
  • Page 27: Screen Setup Menu

    • The value of the settings is between 0 and 120 units. XVII. INSTALLER This menu is reserved for MAGILINE Pools approved professional installers and is protected by an installer identification code. It allows you to configure the various optional equipment that your iMAGI box can control.
  • Page 28: Easymagi Remote Control

    Enables the filter pump to be switched on or off. Stopping it for 15 minutes allowing time to connect the robot to the brush socket or to clean the cartridge Filtration in manual mode for 2 hours Enables or disables accessory output #1 Enables or disables accessory output #2 www.magiline.fr v.201808...
  • Page 29: Reminder

    LID REMOVAL Once the cover is removed, unscrew the 7 fastening screws on the front of the remote control with a small Phillips screwdriver. Then remove the front cover, taking care not to lose the screws. v.201808 www.magiline.fr...
  • Page 30: Removing And Replacing Used Batteries

    Remove used batteries. Step2 Then install the new batteries Reposition the front panel, paying particular attention to the joint, then replace the fixing screws. Reposition the cover and snap it back onto the front panel by pressing it down. www.magiline.fr v.201808...
  • Page 31: Changing The Batteries Imagi Radio Case

    Step 2 Remove used batteries Install new AA batteries Step 3 Reassembling the cover Reposition the cover, paying particular attention to the You can now replace the radio cabinet in its location seal, then replace the fixing screws. v.201808 www.magiline.fr...
  • Page 32: Problems & Solutions

    Stop caused by the remote control to Automatic restart after 15 min or ROBOT BEING Information message use the hydraulic robot momentary by remote control CONNECTED Icon present on the screen in case of an alert. www.magiline.fr v.201808...
  • Page 33: Notes

    ..................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................v.201808 www.magiline.fr...
  • Page 34 The manufacturing of our materials is evolutionary. Their visual representation in this catalogue is indicative and without contractual scope. Our dealers and partners are legally independent companies that carry on their behalf and for their account. Piscines Magiline does not guarantee the sale to the consumer or the installation of its products. Any reproduction and representation,...