Advertisement

Quick Links

Operating Instructions
9046.
Always on the safe side.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9046 and is the answer not in the manual?

Questions and answers

Summary of Contents for KaVo 9046

  • Page 1 Operating Instructions 9046. Always on the safe side.
  • Page 2 Vertrieb: Hersteller: KaVo Dental GmbH Kaltenbach & Voigt GmbH Bismarckring 39 Bismarckring 39 D-88400 Biberach D-88400 Biberach Tel. +49 7351 56-0 www.kavo.com Fax +49 7351 56-1488...
  • Page 3: Table Of Contents

    9046. User information ................................2 A 1.1 Meaning of the pictograms ............................2 A 1.2 Important information ..............................2 A 1.3 Precautions ................................2 A 1.4 Purpose and potential applications ........................3 A 1.5 Technical data ................................3 Description ..................................4 Operation ..................................5 Maintenance ..................................6 Malfunctions ..................................6 Installation ..................................8...
  • Page 4: A 1 User Information

    The following should also be observed: request these from your responsible KaVo agent. Duplication and distribution of the • the work safety regulations, Important information for operator instructions for use (IU) require KaVo's and engineer.
  • Page 5: A 1.4 Purpose And Potential Applications

    9046. A 1.4 Purpose and potential applica- tions The extension set 9046 is used for extending the ABSORmatic plus from 3 to 6 suction points. Max. 4 suction points can be put into operation simultaneously. A 1.5 Technical data Suction path diverter...
  • Page 6: A 2 Description

    9046. A 2 Description Supplementary control ” @ Jacks of external control inputs for suction points 2.1 to 2.4. ” Adjusting wheel for inlet air pressure reducer · # Manometer for regulated inlet air pressure £ £ Mains switch fi Mains jack Ì...
  • Page 7: A 3 Operation

    9046. A 3 Operation When products are operated for the first time and for every operation ” thereafter, it is essential to note the points mentioned in the section «A 1.3 Safety measures » ! Switch on the supplementary control ·...
  • Page 8: A 4 Maintenance

    9046. A 4 Maintenance Repair and maintenance work on the electrical part of the unit may be performed only by qualified specialists or trained per- sons who have been made aware of the safety regulations. For maintenance work, disconnect the mains plug or isolate the unit completely from the mains supply, thus cutting off power to the unit.
  • Page 9 9046. F 04 • CAN fault C • An error occurred during the software initialization of the CAN module. CAN is not ready. R • Switch the unit off and on at the mains switch. If this error occurs several times in succession, call the Customer Service.
  • Page 10: B Installation

    Foot push button 1.000.3147 B 2 Requirements for installation and operation of the extension set • KaVo ABSORmatic plus from software version 3.0. (For checking of the software version, see ABSORmatic plus instructions for use.) With software versions 2.0 to 2.9, the replacement circuit board 1.000.3134...
  • Page 11: The Installation Is Performed In Four Steps

    9046. The installation is performed in four steps: B 3 Installation of the CAN printed circuit board in the suction path switching module of the ABSORmatic plus. B 4 Mounting of the suction path diverter and connection with the suction hoses.
  • Page 12: B 4 Mounting Of The Suction Path Diverter

    9046. B 4 Mounting of the suction path diverter Mounting location Mount the suction path diverter under the bench on the technician’s workstation. The mobility of the Bunsen burner tubes may not be restricted through the mounting of the suction path diverter and the suction hoses.
  • Page 13: B 5 Installation Of The Supplementary Control

    Make CAN connection # between supple- mentary control and ABSORmatic plus. Connect external sealed keypads (option) · via KaVo cable fittings £ to the sub-D jacks. Check for correct assignment. Connect dust-generating consumers to the sockets fi. Connect control lines @ of the external...
  • Page 14: B 6 Commissioning

    9046. B 6 Commissioning Check for correct connection of all compo- nents. Using the adjusting wheel @, set the inlet pressure on the manometer ” to 0.8 bar. Switch on the supplementary control at the mains switch # and then switch on the ABSORmatic plus at the mains switch.
  • Page 15: Guarantee Conditions

    6 months from the date of purchase certified by the sales person. After expiry of the guarantee period, KaVo undertakes to provide a guarantee for a further 6 months for damage due to defects in the material or in the manufacture.
  • Page 16: Spare Parts

    9046. Spare parts Supplementary control circuit board (without figure) 0.696.0301 Protection switch (without figure) 0.223.2371 1.000.7421 DE 0.657.0961 1.000.5396 GB 1.000.7422 FR 1.000.5397 AU 1.000.5395 CH 1.000.5398 US 1.000.5399 JP 0.696.0411...
  • Page 17: Declaration Of Conformity

    Extension set 9046 déclarons que le produit Kit d’extension 9046 declaramos que el producto Juego de ampliación 9046 dichiariamo che il nostro prodotto Kit di ampliamento 9046 verklaren dat het product declaramos que o produto förklarar att produkten erklærer, at produktet...

Table of Contents