Advertisement

Quick Links

Static Contactors
User Manual
ADDRESS : İIkitelli OSB Mah. Environment 14th Block Street. Telas Blok
Exterior Door No: 1 Floor: 1-2 Başakşehir/Istanbul
Tel: +90 212 438 80 24
Fax: +90 212 438 80 25
info@gruparge.com
Version 19-2
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KSK 10 and is the answer not in the manual?

Questions and answers

Summary of Contents for GRUP ARGE KSK 10

  • Page 1 Static Contactors User Manual ADDRESS : İIkitelli OSB Mah. Environment 14th Block Street. Telas Blok Exterior Door No: 1 Floor: 1-2 Başakşehir/Istanbul Tel: +90 212 438 80 24 Fax: +90 212 438 80 25 info@gruparge.com Version 19-2...
  • Page 2: Table Of Contents

    3. 2 Thyristor Capacitive Static Contactor - Three Phase Capacitor Connection Diagram ....6 4. 3 Thyristor Capacitive Static Contactor - Single Phase Capacitor Connection Diagram .... 7 5. KSK 10 Technical Picture ......................8 6. KSK 15-25 Technical Picture ....................9 7.
  • Page 3: Proper Use And Safety Requirements

    Static Contactors User Manual PROPER USE AND SAFETY REQUIREMENTS Cut all the power when connecting and disconnecting the device to a panel. Do not clean the device with a solvent or similar material. Only use a dry cloth. Please do not intervene to the device when a technical problem is encountered and get in contact with a technical service within the shortest time.
  • Page 4: Capacitive Static Contactor Selection Table

    (GA2211) kVAr  The KSK 10 and KSK 20 models are offered with 3 thyristors and are suitable for connecting both single-phase and three-phase capacitors. All other models are offered with 2 thyristors and are only suitable for connecting three-phase capacitors.
  • Page 5: Thyristor Capacitive Static Contactor - Three Phase Capacitor Connection Diagram

    Static Contactors User Manual 3 Thyristor Capacitive Static Contactor - Three Phase Capacitor Connection Diagram (NH BLADE (NH BLADE (NH BLADE INSURANCE) INSURANCE) INSURANCE) SMART TRI RELAY INPUT INPUT OUTPUT INPUT OUTPUT OUTPUT Capacitive Static Contactor Three Phase Harmonic INPUT INPUT INPUT Filter...
  • Page 6: Thyristor Capacitive Static Contactor - Three Phase Capacitor Connection Diagram

    Static Contactors User Manual 3. 2 Thyristor Capacitive Static Contactor - Three Phase Capacitor Connection Diagram (NH BLADE (NH BLADE (NH BLADE INSURANCE) INSURANCE) INSURANCE) NOTE: Static with internal discharge resistor In addition to contactors external discharge resistance there is no need to use it. INPUT INPUT OUTPUT...
  • Page 7: Thyristor Capacitive Static Contactor - Single Phase Capacitor Connection Diagram

    Static Contactors User Manual 4. 3 Thyristor Capacitive Static Contactor - Single Phase Capacitor Connection Diagram (NH BLADE (NH BLADE (NH BLADE INSURANCE) INSURANCE) INSURANCE) SMART TRI RELAY Single phase Single phase Single phase INPUT INPUT OUTPUT OUTPUT INPUT OUTPUT Harmonic Harmonic Harmonic...
  • Page 8: Ksk 10 Technical Picture

    Static Contactors User Manual 5. KSK 10 Technical Picture...
  • Page 9: Ksk 15-25 Technical Picture

    Static Contactors User Manual 6. KSK 15-25 Technical Picture...
  • Page 10: Ksk 20 Technical Picture

    Static Contactors User Manual 7. KSK 20 Technical Picture...
  • Page 11: Ksk 50 Technical Picture

    Static Contactors User Manual 8. KSK 50 Technical Picture...

Table of Contents