Download Print this page

Cafe 98 CB-2 Reference Sheet page 2

Commercial barista series

Advertisement

=
Power Save (Standby) - In this mode the tank temperature will be maintained at approximately 170 degrees when the set
time has been reached. Brew 1 light will flash about once every 10 seconds to indicate unit is in power save mode.
=
Power Down - In this mode the tank heater element will be disabled when the set time has been reached. Brew 2 light
will flash about once every 10 seconds to indicate unit is in power down mode.
SEQUENCE OF PROGRAMMING STEPS FOR THE BARISTA CONTROLLER
=
Depress and hold Cancel button until display lights up (Approx. 10 seconds).
=
You are now in the Program Mode. Functions to be programmed appear in the order in which they are shown in the following table.
=
Use the Cancel button to cycle through the functions to find the one you wish to change.
=
Use the BREW 1 button to lower the displayed value and the BREW 2 button to raise the value. Press Cancel to store the changed value and
advance to next function.
=
If the Brewer detects no activity for approx. 60 seconds it will exit the Program Mode, except as noted below.
CODE
FUNCTION TO SET
1A
Brew 1 time
1b
Brew 2 time
Dual volume- brew1
2a
Double dump feature
Dual volume- brew2
2b
Double dump feature
3
Visa-brew time
Water Temperature 1
4
5
Auto Arm
6A
Pre-infusion 1 mode
6b
Pre-infusion 2 mode
7
Pulse brew mode
7A
Pulse brew 1 time
7b
Pulse brew 2 time
8A
Audible alert mode
8b
Audible alert no. of beeps
9
Coffee freshness monitor
10A
Filtering flow rate
Filter capacity
10b
11
Number of Brews
13A
Power mode
13b
Power shutdown time
None 6
End
1
Brewer will remain in this sequence indefinitely until CANCEL button is pressed. Heating icon will track heater operation.
2
Hidden if pulse brew mode is OFF or brew 1 time is OFF.
3
Hidden if pulse brew mode is OFF or brew 2 time is OFF.
4
Hidden if filter flow rate is OFF.
5
Hidden when power save mode is normal.
6
Program mode will time out in 15 seconds at end of programming sequence.
ERROR MESSAGES
The following table explains the error messages which may be encountered on the brewer. The error messages may be cleared
by going into the program mode, using the brew buttons to display "Clr" and then pressing the cancel button.
ERROR MESSAGE
Er1
Er2
Er3
Er4
Ful
SET VALUES AVAILABLE
OFF, 30 ounces – 255 ounces
OFF, 30 ounces – 255 ounces
ON or OFF
ON or OFF
OFF, 30 seconds – 2 ½ minutes
170 F – 205 F
ON or OFF
ON or OFF
ON or OFF
ON or OFF
2
0 seconds – 60 seconds
3
0 seconds – 60 seconds
ON or OFF
OFF, 1 – 9
10 minutes – 2 hours
OFF, 0.25 – 1.00 gal. / min
4
OFF, 0.50 – 2.50 gal. X 100
Quantity, Clr
Normal, Power Save, Power Down
5
30 minutes – 4 hours
N/A
DESCRIPTION
Fill run error
Heater run error
Shorted probe
Open probe
Filter limit reached
BREW 1
BREW 2
Water filtering Brew 1
Water filtering Brew 2
BREW 1 and BREW 2 (both flashing)
SERVICE
HEATING, (flashing)
BREW 1, (pulsing), COFFEE MONITOR
BREW 2, (pulsing), COFFEE MONITOR
BREW 1 and BREW 2 (pulsing)
BREW 1 (pulsing)
BREW 2 (pulsing)
None
None
COFFEE MONITOR
WATER FILTERING
WATER FILTERING, (flashing)
BREW 1 and BREW 2
None (Displayed P: n, P: s and P: d respectively)
None
None
The fill solenoid has either run for more than six minutes on the initial tank fill
or 3 minutes in normal operation.
The tank heater has run for more than 30 consecutive minutes.
Short in the thermistor circuit.
Break in the thermistor circuit.
The selected filtering capacity of the filter has been reached