Electromagnetic Lock Series
EXML600-GATE & EXML1200-GATE Series
EXML600-GATE
EXML1200-GATE
IMPORTANT REMINDERS
A. Handle the
equipment with care,
damaging the surface
of the magnet or
armature plate may
reduce locking
efficiency.
B. The magnet is
mounted rigidly to the
frame, whereas the
armature plate must
be mounted to the
gate using the items
provided to allow it to
pivot about its centre.
This allows it to
compensate for wear
and misalignment.
External Monitored Magnetic Lock Wiring Instructions
Power Input
12VDC or 24VDC input
A: 12VDC Input:
• Required power 0.5Amp (Minimum)
• Connect the positive (+) lead from a 12VDC power source to +
• Connect the ground (-) lead from a 12VDC power source to –
B: 24VDC Input:
• Required power 0.25Amp (Minimum)
• Connect the positive (+) lead from a 24VDC power source to +
• Connect the ground (-) lead from a 24VDC power source to –
C: Contacts:
• Relay voltage free contacts are rated 1A at 24VDC for safe operation, do not exceed this
• If you require a normally open switch, connect the wires from the system to COM and NO
• If you require a normally closed switch, connect the wires from the system to COM and NC
Wiring the Back-EMF Protection Diode
(+)
Power
Supply
(-)
• Connect the back-EMF Diode in reverse polarity with respect to the magnetic lock polarity.
• The end with the Silver (Grey) Ring connects the (+)ve of the magnetic lock.
(Monitored)
Lock Status Sensor
1: Normally open switch:
2: Normally closed switch: NC & C
12V Wiring Diagram
24V Wiring Diagram
Back-EMF protection diode
NO & C
Red & Yellow to +12VDC
Blue & Black to –VE
White COM
Brown NC
Green NO
Red to +24VDC
Yellow & Blue together
Black to -VE
White COM
Brown NC
Green NO
(+)
Maglock
(-)

Advertisement

loading

Summary of Contents for Oprema EXML600-GATE Series

  • Page 1 Electromagnetic Lock Series EXML600-GATE & EXML1200-GATE Series (Monitored) External Monitored Magnetic Lock Wiring Instructions Lock Status Sensor Power Input 1: Normally open switch: NO & C 12VDC or 24VDC input 2: Normally closed switch: NC & C EXML600-GATE 12V Wiring Diagram Red &...
  • Page 2 Please read before attempting to install Magnetic Lock MOUNTING INSTRUCTIONS Mount the armature plate on the door/gate using the rubber washer. The rubber washer and steel washer are installed between the armature plate and door, using the sex-nut bolt. Typical Installation **IMPORTANT**: Do not install the armature plate too tightly, which ensures the washer remains flexible –...

This manual is also suitable for:

Exml1200-gate seriesExml600-gateExml1200-gate