Do you have a question about the REHP-CO2-160GL-V2 and is the answer not in the manual?
Questions and answers
Hanna Schotten
June 21, 2025
We have a Reclaim 160 V2 Heat pump
How do I connect to the controller to the App with no QR code?
What frequency is the Wifi system 2.5 or 5G
1 comments:
Mr. Anderson
June 21, 2025
To connect the Reclaim 160 V2 Heat Pump controller to the app without a QR code, use the house WiFi. The system supports connection to the Reclaim Mobile app via house WiFi, but the specific connection method without a QR code is not detailed.
The WiFi frequency is not specified as either 2.5GHz or 5GHz. Therefore, the frequency cannot be determined from the given information.
Air-source co2 heat pump hot water system (64 pages)
Summary of Contents for Reclaim REHP-CO2-160GL-V2
Page 1
PRODUCT UPDATE V2 RELEASE QUICK START/INSTALL MANUAL AIR-SOURCE CO2 HEAT PUMP HOT WATER SYSTEM INSTALLATION OPERATION For the full version of installation and owner manuals, please visit: MAINTENANCE reclaimenergy.com.au/downloads...
Page 2
This appliance may deliver water at high temperature. Refer to the Plumbing Code of Australia (PCA), local requirements and installation instructions to determine if additional delivery temperature control is required. Issue 02 | Jan 2023 Reclaim Energy | Quick Start/Install Manual – v2.0...
Page 3
SECTION PAGE Product Update Overview First Time Commissioning Procedure System Description Installation Details Checklist Operation & Maintenance Quick Start/Install Manual – v2.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
V2 RELEASE FEB 2023 PRODUCT SUPPLY CHANGES As of February 2023, Reclaim Energy will launch the next generation of heat pump with some substantial improvements. Unless specified below, all other parameters/ specifications are the same between V1 and V2 models. The two key changes are...
Page 5
18-hour cycle (i.e. this is to ensure the legionella bacterial growth is controlled in a 24 hour cycle) Boost function Available Manuals Website Table B: Key updates on the Reclaim Energy controllers Quick Start/Install Manual – v2.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
Page 6
Full functionality of controller can Available for iOS & Android be used manually or via the FREE mobile phones Reclaim Energy app. Figure B: Reclaim Energy Mobile App used with V2 controller Reclaim Energy | Quick Start/Install Manual – v2.0...
Page 7
EHPE-4540P REHP-CO2-300H RE315AGLH REHP-CO2-315GL-V2 REHP-CO2-315GL EWA-315HPT REHP-CO2-315SSEW-V2 REHP-CO2-315SSEW APS315SH REHP-CO2-315SSQ-V2 REHP-CO2-315SSQ APS315TH REHP-CO2-315SST-V2 REHP-CO2-315SST RE315WIL REHP-CO2-315SS-WIL-V2 REHP-CO2-315SS-WIL RE400AGLH REHP-CO2-400GL-V2 REHP-CO2-400GL APS400TH REHP-CO2-400SST-V2 REHP-CO2-400SST Table C: Updates on the system model IDs Quick Start/Install Manual – v2.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
Page 8
63°C (this if you feel good heat here you are may take up to 4 minutes). done and can comfortably leave knowing you have completed the install successfully. Reclaim Energy | Quick Start/Install Manual – v2.0...
Page 9
Thermister Hot Outlet: 63c Evaporator Cold Inlet Heat Pump Flow Port Heat Pump Unit Drain Elbow COLD MAINS PLV 500 kPa local plumber - not mandatory from system perspective.) Quick Start/Install Manual – v2.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
INSTALLATION DETAILS This section relates to the preparation and the installation proccess for the Reclaim Air-Source CO2 Heat Pump system. SITE INSPECTION AND The installation of a Reclaim Energy air source heat pump can only be completed by a licensed plumber or electrician...
Chloride < 200 mg/L or ppm efficient operation of the system is met. Note that the Reclaim Energy glass-lined tank has a sacrificial anode pH Level Min 6.5 to Max. 8 to protect the vessel from corrosion. The glass line tank...
HEAT PUMP 2.3.2 MOUNTING Note Reclaim Energy ASHP MUST be installed on the Before plumbing and/or wiring of the heat pump unit and ground with mounting frames that is a default supplied integration with the rest of the system, the following component OR on the wall with brackets.
Condensate drain elbow fitting Piping Cover Bottom Panel Figure 8: How to attach/detach the piping cover. PUSH Drain Hose (Market product - ID:16mm) Drain Elbow Figure 7: How to attach drain elbow. Quick Start/Install Manual – v2.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
Page 16
Thermister Cold Inlet Heat Pump Unit COLD MAINS Figure 9: Plumbing diagram of Reclaim Energy ASHP hot water system. PLV 500 kPa 1 The maximum total distance between the 600 kPa (Check with a certified heat pump and tank should not exceed 10m local plumber - not mandatory from system perspective.)
(V1.1 controller) Modbus cable (V2 controller) Heat Pump Unit Figure 10 Wiring diagram of Reclaim Energy ASHP hot water system. IMPORTANT Do not supply power to the controller or heat pump unit before conducting the proccess explained in section 6.5.3 and 6.5.4.
Page 18
POWER SUPPLY TERMINAL BLOCK: Screw with special washer Crimped Cable 10mm cable end Crimp-on terminal Terminal Sleeve blocks Cable Figure 12: How to attach the power cable. Earthing cable Supply cable Electric cable press Reclaim Energy | Quick Start/Install Manual – v2.0...
Page 19
Applicable to V2 controller only: The Wi-Fi function on the controller is enabled and end user successfully connects the controller to the house Wi-Fi and Reclaim Energy mobile app 4. The heat pump is purged by the controller during the commissioning a.
Note this form is not supplied with us or in this document. This is responsibility of customers to have the rebate form ready for the installer to fill out. Reclaim Energy | Quick Start/Install Manual – v2.0...
Page 21
2 – Sensor cable to tank, 3 – Power is connected. Correct time of day has been set up on the first powering. Controller operational mode (OPTION modes) has been set up with reference to the customer requirement. Quick Start/Install Manual – v2.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
If the heat pump runs outside the settings of the active option, this needs to be escalated to the local service agent and/or Reclaim Energy representative for troubleshooting. There are some possibilities for running outsides of setting of controller such as 1) tank sensor is...
If the problem is not solved, HP unit should be replaced. CONTINUES ON NEXT PAGE… Table 11: Details of error codes on external controller and heat pump PCB display and troubleshooting process Quick Start/Install Manual – v2.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
Page 24
PCB (Main) or HP unit Other than described above If the problem is not solved, HP unit shall be replaced. No detection of Please contact Reclaim Energy Support Improve the cause of problem, then Eg-8 Tank sensor Auto tank sensor on: 1300 38 38 15 restart the HP unit.
Or Eg-10 Tank sensor Auto sensor issue possible issue with controller or Please contact Reclaim Energy for temperature sensor. support on: 1300 383815 Please contact Reclaim Energy Modbus cable or V2 controller should Eg-11 Modbus sensor...
Page 26
THIS PAGE WAS INTENTIONALLY LEFT BLANK Reclaim Energy | Quick Start/Install Manual – v2.0...
Page 27
THIS PAGE WAS INTENTIONALLY LEFT BLANK Quick Start/Install Manual – v2.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
Need help?
Do you have a question about the REHP-CO2-160GL-V2 and is the answer not in the manual?
Questions and answers
We have a Reclaim 160 V2 Heat pump How do I connect to the controller to the App with no QR code? What frequency is the Wifi system 2.5 or 5G
To connect the Reclaim 160 V2 Heat Pump controller to the app without a QR code, use the house WiFi. The system supports connection to the Reclaim Mobile app via house WiFi, but the specific connection method without a QR code is not detailed.
The WiFi frequency is not specified as either 2.5GHz or 5GHz.
Therefore, the frequency cannot be determined from the given information.
This answer is automatically generated