Page 3
TABLES OF CONTENTS PRODUCT DESCRIPTION ........................1 Description ............................1 Physical Description..........................1 Applications ............................2 Specification ............................4 INSTALLATION ............................6 Site Selection ............................6 Mechanical and Electrical Installation ....................6 2.2.1 Electrical Installation ........................8 2.2.2 Changing the line connector choice for the E1 ports..............10 Configuration Setting.........................
Page 4
Near End Loopbacks - T1/ E1......................31 4.4.1 Local Loopback.......................... 32 4.4.2 Line Loopback..........................32 4.4.3 Payload Loopback ........................32 Verifying Loop-V4300 Operations ..................... 33 4.5.1 Quick Test ..........................33 4.5.2 Substitution ..........................33 4.5.3 Using Loopback Plugs ....................... 33 4.5.4...
Page 5
System Setup Display ........................54 System Description ........................... 54 Alarm History............................. 55 System Status ........................... 56 Alarm Queue ............................. 56 Loopback Test..........................57 6.10 Alarm Setup............................58 6.11 Password Setup ..........................58 6.12 System Setup ............................ 59 6.12.1 Port............................. 61 6.12.2 MAP ............................
Page 6
Figure 2- 10 Daughter Board Jumper Setting - RJ (100 ohm) T1 ..............16 Figure 3 - 1 SNMP Connection........................29 Figure 4 - 1 Loop-V4300 Loopback Block Diagram ..................32 Figure 5 - 1 Front Panel........................... 35 Figure 5 - 2 Front Panel LCD Menu Tree - Part 1 ..................36 Figure 5 - 3 Front Panel LCD Menu Tree - Part 2 ..................
Page 7
Bitte führen Sie das Gerät am Ende seinerLewbensdauer den zue Verfügung stehended Rückgabeund Sammelsystemen zu. At the end of the product's useful life, please dispose of it at appropriate collection points provided in your country Une fois le produit en fin devie, veuillez le déposer dans un point de recyclage approprié.
Page 8
EMC/EMI: Compliance with : EN 55022 Class A, CISP22 Class A Compliance with : EN 50082, 50081 Compliance with : FCC 15B, Class A Safety Requirements Compliance with : EN 60950, UL1950, CAN/CSA 22.2 NO. 950 Telecom Compliance with : FCC68, CS-03, CE168X - vi -...
Page 9
_________________________ FCC Requirements, Part 68 _________________________ This equipment complies with Part 68 of the FCC rules. On the top cover of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company.
Page 10
Normally, this equipment will be used in conjunction with FCC registered equipment that limits the Encoded Analog Content and provides the required Billing Protection. If the connected equipment is not of this type, an affidavit must be supplied to the telephone company where the network connection is to be made.
Page 11
1. Do not use this product near water, for example, near a bath tub, wash bowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool. 2. Install an AC surge arrestor in the AC outlet to which the Loop Telecom’s equipment is connected.
Page 12
_______________________________________ National Electrical Code Requirements _______________________________________ The Loop-V Mini DACS E1/T1 Converter is ITS Testing Laboratories certified to be in compliance with the Underwriters Laboratories (UL) 1950 Telephone Equipment Standard. The ITS control number is 75425. ____________________________ DOC CS-03 Requirements ____________________________ NOTICE: The Canadian Industry Canada label identifies certified equipment.
Page 13
________________________ CSA 22.2 Requirements _________________________ The Loop-V Mini DACS E1/T1 Converter is ITS Testing Laboratories certified to be in compliance with Canadian Standards Association (CSA) Std 22.2 No. 225 Telephone Equipment Standard. The ITS control number is 75425. _________________________ Compliance _________________________ Loop-V Mini DACS is designed to meet the following standards: •...
Page 14
Loop-V4300 supports DTE port operating from 56 Kbps to 1984 Kbps, This unit is suitable for applications involving 2 to 4 ports. Loop-V4300 also supports inband Management, where management data is carried the same way as user data, traversing national networks.
Page 15
Chapter 1 Product Description Applications The mini DACS series application example is illustrated in the following figures. A: 2 links B: 3 links C: 4 links A1: E1/T1 converter (24 TS) B1: E1/T1 converter (31 TS) and DACS C1: Dual E1/T1 converter and DACS A2: E1 LTU with TSI B2: E1/T1 converter and DACS C2: E1/T1 converter and DACS...
Page 17
Chapter 1 Product Description Specification Network Line Interface (E1) 2.048 Mbps ± 50 ppm Line Rate Line Code AMI / HDB3 Input Signal ITU G.703 Framing ITU G.704 Connector BNC/RJ48C Output Signal ITU G.703 Electrical 75Ω Coax/120Ω twisted pair Network Line Interface (T1) 1.544 Mbps ±...
Page 18
Chapter 1 Product Description Network Management Console Port Connector DB9 at Front Panel Electrical RS232 interface Protocol Menu driven VT-100 terminal Ethernet Port Connector RJ45 in rear Protocol Telnet (VT100) and Embedded SNMP Voice Channel Conversion A-law to μ-law G.711 Signaling bits ABCD are converted using user configurable conversion table Inband Management Any 64 Kbps DS0 can be assigned for management...
Page 19
Mechanical and Electrical Installation Loop-V4300, as a desk top unit, is stackable. The front panel is shown in Figure 2-1, and the rear panel is shown in Figure 2-2. For rack mounting, the Mini DACS can be mounted 1 or 2 units per 1U rack space.
Page 20
Chapter 2 Installation PORT C PORT D ALM RELAY EXT.CLK -V +V PORT B PORT A PORT C PORT D - V.35 ALM RELAY TX-OUT RX-IN EXT.CLK -V +V PORT B PORT A Figure 2- 2 Rear Panels Figure 2- 3 Installation Diagram (Single) Figure 2- 4 Installation Diagram (Double)