Download Print this page

Recom RACM130E-K/OF Installation And Operating Instructions page 2

Ac/dc power supply

Advertisement

Valid for: RACM130E-12SK/OF; RACM130E-15SK/OF; RACM130E-24SK/OF;
RACM130E-36SK/OF; RACM130E-48SK/OF
Installation and Operating Instructions
AC/DC Power Supply: RACM130E-K/OF
Other applicable document:
Important Safety Information
Technical Data
At 115/230VAC, full load forced air cooling, 25°C,
with 5 minute warm-up time unless otherwise stated
Peak Power
Output Voltage (Factory Setting)
Output Current
Efficiency
Nominal Input Voltage Range
Operating Range
Input Current
Inrush Current (cold start)
Hold Up Time
Internal Input Fuse
Over Voltage Protection
Over Voltage Category
Over Current Protection
Operating Temperature
Operating Humidity
Operating Altitude
Storage Conditions
Dimensions / Weight
Approvals
horizontal (standard)
Warranty
AC
DC
airflow
Fig. 1: Mounting / Montage
vertical / vertikal
If module is horizontal or side mounted no derating is required. If module is mounted vertical or
upside down with natural convection cooling, the power must be derated at least 10%.
Wenn das Modul horizontal oder seitlich montiert wird, ist keine Leistungsrücknahme erforderlich. Wenn
das Modul, bei natürlicher Konfektionskühlung, vertikal oder kopfüber montiert wird, muss die Leistung um
mindestens 10% verringert werden.
vertical
Fig. 2: Derating Graph / Temperaturverhalten
Still air convection cooled ratings / Leistung bei ruhender Luft mit Konvektionskühlung
(@ natural convection 0.1m/s) / (@ natürlicher Konvektion 0.1m/s)
upside-down
100VAC
130
120
AC
DC
110
100
90
80
70
60
50
40
30
24Vout
20
12/15/36/48Vout
10
0
-40
-20
0
20
40
Ambient Temperature [°C]
Umgebungstemperatur [°C]
Line Rating / Leistungsbewertung
(@ 1m/s airflow) / (@ 1m/s Luftstrom)
130
120
110
100
90
80
70
60
50
40
30
20
10
0
80
90 100
103
180
Input Voltage [VAC]
Eingangsspannung [VAC]
Technische Daten
Bei 115/230VAC, Volllast, Zwangsbelüftung, 25°C, nach
5 Minuten Aufwärmzeit, wenn nicht anders angegeben
Spitzenausgangsleistung
Ausgangsspannung (Werkseinstellung)
Ausgangsstrom
Wirkungsgrad
Nominaler Eingangsspannungsbereich
Betriebsbereich
Eingangsstrom
Einschaltspitzenstrom (Kaltstart)
Pufferzeit
Interne Eingangssicherung
Überspannungsschutz
horizontal (standard)
Überspannungskategorie
AC
DC
Überstromschutz
Betriebstemperatur
Betriebsluftfeuchtigkeit
Betriebshöhe
Lagerbedingungen
Abmessungen / Gewicht
Zulassungen
Garantie
horizontal (standard)
AC
DC
vertical
upside-down
upside down / kopfüber
airflow
AC
Luftstrom
DC
vertical
130
120
110
upside-down
100
90
80
airflow
70
60
AC
DC
50
40
24Vout
30
36/48Vout
20
15Vout
12Vout
10
0
60
80
100
-40
-20
0
90
Ambient Temperature [°C]
Umgebungstemperatur [°C]
Thermal Derating / Thermisches Derating
100
90
80
70
60
50
40
30
25
20
24/36/48Vout
12/15Vout
10
0
264
-40
-20
0
Ambient Temperature [°C]
Umgebungstemperatur [°C]
Revision: 0/2022
Document no.: IMG144
©RECOM Power GmbH. The information contained in
this instructions and accompanying drawings are the
intellectual property of RECOM Power GmbH.
This manual can change without prior notice.
RACM130E-12SK/OF
RACM130E-15SK/OF
130W
130W
12VDC
15VDC
10.8A
8.66A
86%
88%
120% - 180%, auto recovery / 120% - 180%, automatischer Neustart
OVCIII (up to 2000m) according to 61558-2-16, OVCII according to 60601-1 / OVCIII (bis 2000m) nach 61558-2-16, OVCII nach 60601-1
110% - 180%, auto recovery / 110% - 180%, automatischer Neustart
airflow
-40°C to +90°C with derating (refer to Fig. 2) / mit Leistungsreduzierung (siehe Fig. 2)
4000m (OVCII) according to 60601-1, 2000m (OVCIII) according to 61558-2-16 / 4000m (OVCII) nach 60601-1, 2000m (OVCIII) nach 61558-2-16
-40°C to +90°C, 95% RH max. (non condensing) / -40°C bis +90°C, 95% RH max. (nicht kondensierend)
CAN/CSA-C22.2 No. 60601-1:14, ANSI/AAMI ES60601-1, IEC/EN60601-1, IEC/EN62368-1, IEC/EN60335-1, IEC/EN61558-2-16, IEC/EN61558-1
Fig. 3: Peak Load Capability / Spitzenbelastbarkeit
(@ 0.1 m/s natural convection)
Luftstrom
airflow
...peak output power (≤130W)
P
120-240VAC
P
...Spitzenausgangsleistung (≤130W) [W]
P
...recovery output power / Leistung der Entlastungsphase [W]
r
t
.. peak time set (10s max.) / Zeitspanne der Überlast (10s max.) [W]
1
t
...recovery time (min. 3 x t
2
k
...safety factor 1.2 / Sicherheitsfaktor 1.2
100 x (t
P
=
r
Fig. 4: Block Diagram / Block Diagramm
20
40
60
80
100
30
90
45 50
68
L
N
20
40
60
80
100
120
50
90
*
TechsupportAT@recom-power.com
RACM130E-24SK/OF
130W
24VDC
5.42A
88%
50/60Hz, 100-240VAC
47-63Hz85-264VAC or 120-370VDC
2A @115VAC / 1.5A @230VAC
30A @115VAC / 60A @ 230VAC
16ms @115VAC / 70ms @230VAC
T4A, slow blow / T4A, Träge
95% RH max.
101.6 x 50.8 x 32.0mm / 200g typ.
3 years / 3 Jahre
130
120
110
100
90
80
70
60
50
40
30
20
10
0
80
90 100
103
Input Voltage [VAC]
Eingangsspannung [VAC]
) / Entlastungszeit (min. 3 x t
) [s]
1
1
+ t
) - (P
x t
)
1
2
P
1
t
x k
2
T4A
Input Filter
Rectifier
T4A
Eingangs-
Gleichrichter
filter
Snubber
Snubber
Flyback Controller
Flyback-Steuerung
Steuerung für die aktive Gleichrichtung +
RECOM Power GmbH
Münzfeld 35, 4810 Gmunden, AUSTRIA
+43 7612 88325 700
+43 7612 88325 801
7
www.recom-power.com
RACM130E-36SK/OF
RACM130E-48SK/OF
130W
130W
36VDC
48VDC
3.61A
2.71A
88%
88%
others peak load
12Vout peak load
180
264
Pout [W]
P
p
P
nom
P
r
Time [s]
0
t
t
1
2
Active
Output Filter
Rectification
Ausgangs-
Aktive
filter
Gleichrichtung
Feedback
Regelstrecke
Rectification Controller
+ Feedback Loop
Regelung der Ausgangsspannung
+V
-V

Advertisement

loading

This manual is also suitable for:

Racm130e-12sk/ofRacm130e-15sk/ofRacm130e-24sk/ofRacm130e-36sk/ofRacm130e-48sk/of