Advertisement

Quick Links

INSTRUCTIONS
FOR INSTALLATION AND USE
DFS4P - D3FS12P - D2FS8P - D2FPS12P
GAS HOB FOR RESIDENTIAL AND PROFESSIONAL USE

Advertisement

Table of Contents
loading

Summary of Contents for Officine Gullo DFS4P

  • Page 1 INSTRUCTIONS FOR INSTALLATION AND USE DFS4P - D3FS12P - D2FS8P - D2FPS12P GAS HOB FOR RESIDENTIAL AND PROFESSIONAL USE...
  • Page 2 14. In case of failure or malfunction, turn the appliance off, close the gas supply valve and do not attempt to carry out any repairs, which must be done exclusively by an authorized service center. Request the use of original spare parts only. Failure to comply with the above recommendations may compromise the appliance’s safety. Officine Gullo...
  • Page 3: Table Of Contents

    WHAT TO DO IN THE EVENT OF A BREAKDOWN ..............18 PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR SOME TIME ..18 MAINTENANCE (only for qualified personnel) ................18 INSTRUCTIONS FOR DISCHARGING GAS EMISSIONS ............18 Officine Gullo...
  • Page 4: Installation Manual

    INSTALLATION MANUAL FIG.A/1 DFS4P E. Electrical Connection G. Gas Connection ISO 7–1 1/2 ”M Officine Gullo...
  • Page 5 Fig. A/2 D3FS12P E. Electrical Connection G. Gas Connection ISO 7–1 3/4 ”M Officine Gullo...
  • Page 6 Fig. A/3 D2FS8P E. Electrical Connection G. Gas Connection ISO 7–1 1/2 ”M Officine Gullo...
  • Page 7 Fig. A/4 D2FPS12P E. Electrical Connection G. Gas Connection ISO 7–1 3/4 ”M Officine Gullo...
  • Page 8 Einspritzventil flamme Injecteur feux Injector cooking rings Inyector fuegos Regolazione aria Luftregelung Réglage d'air Air regulation Regulación aire 2. Air regulation 4. Thermocouple Candela accensione Zündkerze Bougie d'allumage Lighting spark plug Candela encendido Termocoppia Thermoelement Thermocouple Thermocouple Termopar Officine Gullo...
  • Page 9 Fig. D Coup de feu FIG.K (TUTTAPIASTRA, GLÜHPLATTENHERDEN, PLAQUE, SOLID TOP, PLACA) Injector Pilot Iniettore Einspritzventil Injecteur Injector Inyector Gruppo pilota ZündBrenner Veilleuse Pilot Piloto Officine Gullo...
  • Page 10 Fig. E WIRING DIAGRAM - TOP   Electrical connection Push-button starting burner 3/4. Power-station starting burner Officine Gullo...
  • Page 11: Declaration Of Compliance

    DECLARATION OF COMPLIANCE This appliance is manufactured by OFFICINE GULLO S.r.l Headquarters and factory Via Della Torricella 29, Antella, Bagno a Ripoli 50012 Florence - Italy Tel. +39 055 65 60 3324 +39 055 62 18 07 officinegullo.com | info@officinegullo.com The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 2009/142 for the gas part and with norm 2006/95/CE, 2004/108/CE for the electric part.
  • Page 12: Installation

    Take suitable measures to guarantee thermal insulation of the inflammable sides, such as, for example, the installation of protection against radiation. The appliances must be installed in a suitable manner, observing the safety standards. The small feet are adjustable to level the appliance. Officine Gullo...
  • Page 13: Pipe For Gas Connection

    Connection with natural gas H G20 The connection pressure for natural gas is 20 mbar. Check the plate, read the pressure and verify that the description of the nozzle installed corresponds to the one supplied by the manufacturer. Officine Gullo...
  • Page 14: Checking Primary Air To The Main Burners

    0,794 Primary air h=mm Burner Coup de Feu 7 kW- min. 4 kW Burner Injector 1/100 mm 130A 130A Min. output adjustment 1/100 mm adjustable Pilot Injector 1/100 mm Consumption kg/h 0,552 kg/h 0,544 m3 st./h 0,740 Officine Gullo...
  • Page 15: Rules For Converting And Installing Other Types Of Gas

    4 kW. The primary air of the all plate burner does not need adjusting. Attention: If liquid gas is used, the minimum flame adjustment screw must be screwed right down. Officine Gullo...
  • Page 16: Checking Functioning

    If the flame goes out you have to repeat the procedure. By turning the knob round to the position the burner is at maximum. By turning the knob round to the position the burner is at minimum. To switch off, move the knob back into position " 0". Officine Gullo...
  • Page 17: Cleaning And Maintenance

    Do not use abrasive pads or any other chemical products. Cleaning brushed steel surfaces All the brushed steel surfaces should be cleaned using degreasing products or products specifically designed to be used on steel and, where necessary, extra-fine steel wool or extra-thin sandpaper. Officine Gullo...
  • Page 18: What To Do In The Event Of A Breakdown

    Supplying the appliance with gas again must only be possible manually. NATURAL DISCHARGE NATURAL DISCHARGE FORCED DISCHARGE FORCED DISCHARGE Fig.1 Fig.1 Fig.2 Fig.2 1. Extractor hood 1. Extractor hood 1. Extractor hood 1. Extractor hood 2. Interlocking 2. Interlocking Officine Gullo...
  • Page 19 Officine Gullo...
  • Page 20 international V 2.3 - 12.18 Tel. +39 055 656 0324 | info@officinegullo.com Via Della Torricella 29, Antella, Bagno a Ripoli - 50012 Florence - Italy OFFICINEGULLO.COM...

This manual is also suitable for:

D3fs12pD2fs8pD2fps12p

Table of Contents