INSTRUCTIONS FOR INSTALLATION AND USE DFS4P - D3FS12P - D2FS8P - D2FPS12P GAS HOB FOR RESIDENTIAL AND PROFESSIONAL USE...
Page 2
14. In case of failure or malfunction, turn the appliance off, close the gas supply valve and do not attempt to carry out any repairs, which must be done exclusively by an authorized service center. Request the use of original spare parts only. Failure to comply with the above recommendations may compromise the appliance’s safety. Officine Gullo...
WHAT TO DO IN THE EVENT OF A BREAKDOWN ..............18 PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR SOME TIME ..18 MAINTENANCE (only for qualified personnel) ................18 INSTRUCTIONS FOR DISCHARGING GAS EMISSIONS ............18 Officine Gullo...
DECLARATION OF COMPLIANCE This appliance is manufactured by OFFICINE GULLO S.r.l Headquarters and factory Via Della Torricella 29, Antella, Bagno a Ripoli 50012 Florence - Italy Tel. +39 055 65 60 3324 +39 055 62 18 07 officinegullo.com | info@officinegullo.com The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 2009/142 for the gas part and with norm 2006/95/CE, 2004/108/CE for the electric part.
Take suitable measures to guarantee thermal insulation of the inflammable sides, such as, for example, the installation of protection against radiation. The appliances must be installed in a suitable manner, observing the safety standards. The small feet are adjustable to level the appliance. Officine Gullo...
Connection with natural gas H G20 The connection pressure for natural gas is 20 mbar. Check the plate, read the pressure and verify that the description of the nozzle installed corresponds to the one supplied by the manufacturer. Officine Gullo...
0,794 Primary air h=mm Burner Coup de Feu 7 kW- min. 4 kW Burner Injector 1/100 mm 130A 130A Min. output adjustment 1/100 mm adjustable Pilot Injector 1/100 mm Consumption kg/h 0,552 kg/h 0,544 m3 st./h 0,740 Officine Gullo...
4 kW. The primary air of the all plate burner does not need adjusting. Attention: If liquid gas is used, the minimum flame adjustment screw must be screwed right down. Officine Gullo...
If the flame goes out you have to repeat the procedure. By turning the knob round to the position the burner is at maximum. By turning the knob round to the position the burner is at minimum. To switch off, move the knob back into position " 0". Officine Gullo...
Do not use abrasive pads or any other chemical products. Cleaning brushed steel surfaces All the brushed steel surfaces should be cleaned using degreasing products or products specifically designed to be used on steel and, where necessary, extra-fine steel wool or extra-thin sandpaper. Officine Gullo...