    PHOTOELECTRIC BARRIER MINERVA 73/23/CEE 89/336/CEE INSTALLATION, USE AND MAINTENANCE LIST OF CONTENTS WARNING..........................2 GENERAL ..........................3 OPERATION ........................... 3 DIMENSIONS.......................... 4 INDICATORS .......................... 6 TECHNICAL DATA........................6 INSTALLATION........................7 SAFETY DISTANCE AND POSITIONING................8 Single beam protection.....................9 Double beam protection ...................9 Distance from reflecting surfaces ................10...
  • Page 3: Warning

    EC machine directive 89/392. WARNING The MINERVA safety system consists of one or two pairs of photocells connected to the standard control unit AU S3, the control unit with integrated muting function AU S3M2 or the control unit AU S-TWIN (up to four pairs of photocells). To gain an understanding of...
  • Page 4: General

    GENERAL MINERVA is a barrier type photocell consisting of a separate emitter and receiver. When it is connected to the standard control units AU S3, AU S-TWIN or the integrated unit with muting function AU S3M2, MINERVA represents a type 2 safety system for the protection against accidents of people exposed to hazards on dangerous machinery.
  • Page 5: Dimensions

    DIMENSIONS Emitter and receiver Fastening brackets...
  • Page 6 Deflector mirrors Model SP 200S SP 200S Fastening brackets for the deflector mirrors CM9 CONNECTOR (M12 4 pins PG9∅ ∅ ∅ ∅ 6 -8 mm) connections: screw type terminals...
  • Page 7: Indicators

    INDICATORS COLOUR STATUS INDICATION Yellow Beam emitted EMITTER Yellow Eteinte No beam Controlled area Two-colour Green ON is free RECEIVER Controlled area Two-colour Red ON is obstructed Figure 1 TECHNICAL DATA MODEL MNE-EMITTER MNR-RECEIVER Effective capacity 0 ÷ 8 Minimum item detectable Immunity to ambient light >...
  • Page 8: Installation

    INSTALLATION The MINERVA photocell system used in conjunction with a AU S3, AU S-TWIN or AU S3M2 control unit represents a type 2 electro-sensitive safety protection system. As provided for by international standards 61496-1 and prEN61496-2, in type 2 safety devices, possible faults or malfunctioning must be detected during the testing stage.
  • Page 9: Safety Distance And Positioning

    Recommended Fc factors are listed in the table below: ENVIRONMENTAL CONDITION CORRECTION FACTOR Fc Mist 0,25 Vapours 0,50 Dust 0,50 Dense fumes 0,25 SAFETY DISTANCE AND POSITIONING The photocell must be installed at a distance greater than or equal to the minimum safety distance, S, so that no hazardous point can be reached until the hazardous action of the machine has stopped (fig.
  • Page 10: Single Beam Protection

    Figure 4 Double beam protection Through the use of two overlapping MINERVA photocells with the two beams aligned one on top of the other it proves possible to create a double beam protection set-up. In this case, the minimum safety distance must be calculated from the following formula:...
  • Page 11: Distance From Reflecting Surfaces

    Figure 5 Multiple systems When using 2 pairs of MINERVA systems, whether placed side by side or one on top of the other, make sure they do not interfere with one another by arranging the elements so that the beam emitted by the emitter of either system is received only by the...
  • Page 12: Use Of Deflector Mirrors

    Use of deflector mirrors For the protection and control of areas that can be accessed from several sides, in addition to the emitter and the receiver you can also use one or more deflector mirrors. Deflector mirrors, in fact, make it possible to reflect back on several sides the optical beams generated by the emitter.
  • Page 13: Electrical Connections

    (e.g., self-testing) must follow a different route than the other power cables. To ensure trouble-free operation of the MINERVA photoelectric system it is important to read some sections of the respective installation manuals, and, in particular: •...
  • Page 14 Connection with AU S3 unit MINERVA MINERVA AU S3 Connection with AU S3 unit and control by means of auxiliary external relays, K1 and K2. MINERVA MINERVA AU S3...
  • Page 15 Connection with AU S3M2 muting unit...
  • Page 16 Connection with AU S3M2 muting unit and control by means of auxiliary external relays, K1 and K2 WARNING: To connect the muting sensors, refer to "MUTING, AU S3M2 safety unit" Manual.
  • Page 17 Connection of four pairs of photocells with AU S-TWIN unit and with auxiliary external relays, K1 and K2 MINERVA MINERVA MINERVA MINERVA AU S-TWIN MINERVA MINERVA MINERVA MINERVA...
  • Page 18: Mechanical Assembly And Optical Alignment

    Connection of two pairs of photocells with AU S3 unit or AU S3 M2 muting unit Mechanical assembly and optical alignment The emitter and the receiver must be assembled one in front of the other at a distance not to exceed the effective capacity of the equipment, by means of the fastening brackets (page 6) supplied as standards: for the assembly of the latter see fig.
  • Page 19: Checking And Maintenance

    Figure 9 CHECKING and MAINTENANCE The MINERVA photocell must be used within the operating temperature parameters given in the technical data. Before each work shift or power-up, verify the correct operation of the photocell through the following procedure: intercept the beam by means of a non-transparent cylinder shaped object with 12 mm diameter, to be placed first in the centre of the area between the emitter and the receiver, and then close to both components.
  • Page 20: Identification Labels

    IDENTIFICATION LABELS S/N field codification: Year of production Part Number Week of production Ordering codes ITEM CODE Emitter + Receiver 1200200 Emitter MNE 1400200 Receiver MNR 1500200 Options ITEM CODE SP 200S 1201800 Deflection mirror SP 400S 1201801 Spare parts ITEM CODE Fastening bracket kit (1 bracket, nuts and screws)
  • Page 21: Warranty

    The validity of this warranty is subject to the following conditions: • Notice of the fault has been transmitted by the user to REER S.p.A. within twelve months of the date of delivery of the product. •...