Guide for installation, use and maintenance INDEX GENERAL INFORMATION ........................3 The user guide .....................................3 The manufacturer....................................3 Communicating with the manufacturer ...............................3 Identification of the blowing unit................................3 1.4.1 Identification plate ....................................3 Technical service provider..................................4 Safety ........................................4 1.6.1 General and safety warnings ................................5 Warranty.......................................5 Symbols/Explanations of the manual..............................6 Certificate CE of compliance................................7...
Page 4
TECHNICAL AND IT DATA AND THE PREPARATION OF TEXTS AND GRAPHICAL ARRANGEMENTS: PREPARED BY SISTEM AIR’S DESIGN OFFICE. SISTEM AIR RESERVES ALL RIGHTS TO THIS MANUAL; NO PARTIAL OR WHOLE REPRODUCTION IS ALLOWED WITHOUT WRITTEN AUTHORISATION FROM SISTEM AIR No part of this document may be reproduced, copied or disclosed by any means without the written authorization of TECNOPLUS s.r.l., the owner of the SISTEM-AIR trademark.
Detailed indications of the problem you are encountering. The complete technical features relative to the blowing unit reproduced on the IDENTIFICATION PLATE located on the unit. • 1.4 Identification of the blowing unit This instruction manual covering use and maintenance refers to the following product: - 060005Q - 060005QE - 060006Q - 060006QE - 060008Q...
Guide for installation, use and maintenance • 1.5 Technical service provider If necessary, contact only the manufacturer's Support Service or its Authorized Center. Always specify the technical data shown on the identification plate and the serial number of the central vacuum unit. Technical Service Provider Authorized Assistance Center •...
Guide for installation, use and maintenance • 1.6.1 General and safety warnings Read carefully any information in this guide about the installation, use and maintenance of the suction unit contained in this manual. This instruction booklet is an integral and essential part of this product and must be given to the user. We recommended using it and keeping it safe for the entire service life of the system.
Guide for installation, use and maintenance • 1.8 Symbols/Explanations of the manual In this manual are used tecnical and convential words. In order to faciliate the comprehension of the instructions you can find the most frequently words used in the follwing list: 1) Discharge pipe Connection pipe to dust separator Metal collar...
Guide for installation, use and maintenance • 1.9 Certificate CE of compliance DECLARATION OF CONFORMITY The company, TECNOPLUS S.r.l. Via Cilavegna, 53 27020 Gravellona Lomellina (PV) ITALIA Declares, on his own responsability, that the products of the industrial series: -Blowing power units Model:_________________ Item N°:_________________ Serial N°...
Guide for installation, use and maintenance • 2.3 Unpacking Do not remove the packaging before installing or activating the suction unit in order to avoid damages. WARNING: - The manufacturer declines all responsibility for damage to the vacuum module delivered if you open the packaging incorrectly. - The parts of the packaging that come with the machine when it is delivered are aggregate waste and must be disposed of in compliance with the current legislation in force.
Guide for installation, use and maintenance • 2.4 Control of the accessories Do an inventory of the items received: - N°1 central vacuum unit - N°2 rubber couplings for connection to the discharge and vacuum pipe net - N°4 metal collars to fix the couplings - N°1 Guide for installation use and maintenance - N°1 Panel regulating motor speed (only on pre-fitted models) - N°1 Warranty certificate...
Guide for installation, use and maintenance 3 - DESCRIPTION OF THE BLOWING UNIT • 3.1 Operating principles The central vacuum system, suitable for any kind of residential building (civilian housing, office, hotel, service sectoir), consists of chased. wall-mounted or suspended ceiling - mounted PVC pipes network, which branches off into the various locations.
Never vacuum liquids! The vacuum module must be used together with a SISTEM AIR filtering separator to vacuum dust or small scraps left over from work.The air sucked in by the turbine must always be filtered. Take particular care to ensure that no solid objects even very small ones, end up inside the turbine as this could cause serious damage.
Guide for installation, use and maintenance • 3.3 Compliance with EEC Regulations in force The central vacuum unit described in this manual comply with the following European Community Directives: 98/37/CEE - Machinery Directive (ex 89/392/CEE) and subsequent amendments 73/23/CEE - Low Voltage Directive (and subsequent amendments) 89/336/CEE - Electromagnetic Compatibility Directive (and subsequent amendments) •...
Guide for installation, use and maintenance • 3.7 Technical features Measurement tables and technical data BLOWING POWER UNIT ARTICLE 060005Q 060006Q 060008Q 060005QE 060006QE 060008QE 060010QE Max.number of operators Electronic speed converter Insulation level Power fasi/ Volt ac 3/380 3/380...
Guide for installation, use and maintenance • 3.8 Electric control panel description The electric control panel is situated on the frontal protection cover of the vacuum unit. Protection cover Main switch (Magnetic thermal) - for models ..QE Main switch (thermal motorsafety system) - for models ..Q Warning light MICRO LINE switch •...
Guide for installation, use and maintenance 4 - INSTALLATION • 4.1 Precautions - CAUTION - THESE PROCEDURES MUST BE CARRIED OUT ONLY BY QUALIFIED PERSONNEL! In the following we proved several essential rules to be followed for correct installation within a building. For the installation you need an adapted magnetic thermal safety switch on the frontal side of the unit.
Guide for installation, use and maintenance • 4.5 Type of installation There exist multifaceted types of installations, depending on the dimensions, on the number of operators and on the type of environment where the central vacuum has to be installed. The basic solution is composed of one vacuum unit and of one separator, that are connected to a vacuum and discharge pipe net and to the power supply system.
Guide for installation, use and maintenance • 4.6 Connection to the pipe network Using the coupling and the metal collar provided connect the unit to the air aspiration pipe network. Fix the silencer. According to the dimensions and the type of blowing unit, fix the silencer to the screw connector. 1) Discharge pipe Vacuum pipe Metal collar...
Guide for installation, use and maintenance • 4.7 Electric connection - IMPORTANT - BEFORE CARRYING OUT ANY OPERATION, DISCONNECT FROM THE POWER MAINS. - CAUTION - The electrical power system for the central vacuum unit must be fitted by a qualified person and in compliance with the current legislation in force.
380/400V~ IP 20 Carry out the electrical connection to the terminal strip observing the layout and the options shown on the inside the box and below: - 060005QE - 060005Q - 060006QE Motori Cod.: - 060006Q Motori Cod.:...
Article N° PANEL MAX.MOTORS SUPPLY Volt ac Frequency Hz FOR MOTORS Article: 3301.6 220/240 060005Q 3301.0 220/240 060006Q 060008Q 3301.10 220/240 • 5.1.2 Operating The control panel control the motor start sequence. • 5.1.3 Switch ON and OFF To activate the control panel turn the main switch on the "I-ON" position.
Guide for installation, use and maintenance • 5.2 Eletrical control panel Mod. 3301.5 - 3301.7 Control panel for the modulation of the motor speed The electronic panel for the modulation of the speed of the motor body, is used when you one electronic motor is installed. The internal electronic system allows for the installation on the micro switch line, using the resistive divider (parts no.3301.4) to control the speed of the motor body according to the number of inlet valves used, and to obtain greater performance with lower consumption.
• 5.3 Summary table of available speeds Summary table of available speeds and kind of selection Speed can be set manually Speed can be modulated Speed converter Electronic board for MODEL ARTICLE electronically speed modulation 060005Q 060006Q 060008Q Industrial motors 060005QE 060006QE 060008QE 060010QE Description = Number of speeds that can be set (e.g.
Guide for installation, use and maintenance 5.4 Electrical schema The following descriptions represent the electric connection schemas for the standard installations. For particular connections please ask to an authorised distributor. • 5.4.1 Electrical schema 1 electrical motor - 1 dust separator with self-cleaning system Schema collegamento elettrico 1 motore elettrico 380 Vac e 1 separatore con autopulizia SCH-EL-0014...
Guide for installation, use and maintenance • 5.4.2 Electrical schema 2 electrical motors - 1 dust separator with self-cleaning system and control panel Art. 3301.6 Mot SOFF 11/05-V01 Mot SOFF 11/05-V01...
Guide for installation, use and maintenance • 5.4.3 Electrical schema 3 electrical motors - 1 dust separator with self-cleaning system and control panel Art. 3301.0 Mot SOFF 11/05-V01 Mot SOFF 11/05-V01...
Guide for installation, use and maintenance • 5.4.4 Electrical schema 1 electronic motor - 1 dust separator with self-cleaning system and control panel Art. 3301.5 Schema collegamento elettrico 1 motore elettronico 380 Vac e 1 separatore con autopulizia SCH-EL-0010 Mot SOFF 11/05-V01 Mot SOFF 11/05-V01...
Guide for installation, use and maintenance • 5.4.5 Electrical schema 2 electronic motors - 1 dust separator with self-cleaning system and control panel Art. 3301.7 Mot SOFF 11/05-V01 Mot SOFF 11/05-V01...
Guide for installation, use and maintenance • 5.4.6 Electrical schema 1 electrical motor - 1 dust separator without self-cleaning system Schema collegamento elettrico 1 motore elettrico 380 Vac e 1 separatore senza autopulizia SCH-EL-0016 Mot SOFF 11/05-V01 Mot SOFF 11/05-V01...
Guide for installation, use and maintenance • 5.4.7 Electrical schema 2 electrical motors - 1 dust separator without self-cleaning system and control panel Art. 3301.6 Mot SOFF 11/05-V01 Mot SOFF 11/05-V01...
Guide for installation, use and maintenance • 5.4.8 Electrical schema 3 electrical motors - 1 dust separator without self-cleaning system and control panel Art. 3301.0 Mot SOFF 11/05-V01 Mot SOFF 11/05-V01...
Guide for installation, use and maintenance • 5.4.9 Electrical schema 1 electronic motor - 1 dust separator without self-cleaning system and control panel Art. 3301.5 Schema collegamento elettrico 1 motore elettronico 380 Vac, e 1 separatore senza autopulizia SCH-EL-0019 Mot SOFF 11/05-V01 Mot SOFF 11/05-V01...
Guide for installation, use and maintenance • 5.4.10 Electrical schema 2 electronic motors - 1 dust separator without self-cleaning system and control panel Art. 3301.7 Mot SOFF 11/05-V01 Mot SOFF 11/05-V01...
Unit model CALIBRATION OF THE PRESSURE VALUE V ac Art. Depending on the installations, calibrate the compensation valve 060005Q in order to get the best performance check that the turbine , but 060005QE does not exceed the maximum absorption shown on the plate.
Install the valve in the right sense, by facing upwards the indicating arrow Metal collar towards the air discharge pipe. Connector BLOWING UNITS ARTICLE 060005Q 060006Q 060008Q 060005QE 060006QE 060008QE 060010QE (2") 0110001 (3") 0110003 (4") 0110002 ø...
Guide for installation, use and maintenance 7 - TESTING • 7.1 Testing notes The final test helps to verify that the central vacuum unit has been installed properly. Useful parts for the test: Srew cap for testing installation vacuum gauge flexible hose for cleaning Proceed as follows: 1) - Connect the vacuum gauge to the inlet connector and after 8/10 Sec.read off the maximum working pressure when the...
Guide for installation, use and maintenance 8 - USE OF THE BLOWING UNITS • 8.1 Usage Once you have finished the installation, the electric connection, and the micro switch line of the inlets, it is possible to start the central vacuum unit. Start Open the suction inlet in oredr to start the suction unit.
Guide for installation, use and maintenance 9 - MAINTENANCE • 9.1 Programmed routine maintenance - CAUTION - BEFORE CARRYING OUT ANY MAINTENANCE WORK, THE POWER CABLE MUST BE DISCONNECTED FROM THE POWER SOURCE AND SAFETY GLOVES AND MASK MUST BE WORN. T h e p r o g r a m m e d r o u t i n e...
Guide for installation, use and maintenance 10 - SERVICING • 10.1 Servicing criteria It is absolutely prohibited to perform procedures on the central vacuum system for repairs and / or maintenance that is not expressely authorized (and therefore not allowed) in the manual. All procedures for repair of wear or malfunction must be done by qualified personnel from the Technical Assistance.
Guide for installation, use and maintenance • 12.2 Material list In order to faciliate the recycling of the material and in order to conserve the environment we create a list including the material components of the central vacuum unit. Disposal and/or recycling of any components of the central system must be done in compliance with the laws in force. Material Included in Note...
Guide for installation, use and maintenance 14 - TROUBLESHOOTING • 14.1 Troubleshooting Problem Possible cause Possible remedy The power supply cable is Connect the power supply cable. disconnected The main switch is off or Check and activate the 2 switches bringing it into the micro line switch is off the I-ON position The micro line activation signal...
Need help?
Do you have a question about the 060005Q and is the answer not in the manual?
Questions and answers