Electronic sensor tap

Advertisement

Quick Links

L-960 Series
Electronic Sensor Tap
L-961
L-962
Pavilion View, Newby Rd
Stockport SK7 5DA
Installation and
Maintenance Guide
T 0845 130 2907
F 0845 130 2908
technical@lovair.com
lovair.com

Advertisement

Table of Contents
loading

Summary of Contents for lovair L-960 Series

  • Page 1 Installation and Maintenance Guide L-960 Series Electronic Sensor Tap L-961 L-962 Pavilion View, Newby Rd T 0845 130 2907 technical@lovair.com Stockport SK7 5DA F 0845 130 2908 lovair.com...
  • Page 2 Index Technical Data Pack Contents Pre - Installation Information 06-08 Tap Installation 09-12 Setting Adjustment Battery Replacement Spare Parts List Maintenance Warranty Troubleshooting lovair.com...
  • Page 3: Technical Data

    Technical Data L961 L962 Power supply: 9V battery or 9V transformer Recommended water pressure: 0.5-8.0 bar (7-116 PSI) With water pressure of more than 8 bars, use a pressure reducing valve for reduction. Preset sensor range: 170 mm Adjustable. Minimum sensor range: 80 mm Maximum sensor range: 300 mm...
  • Page 4 9V battery is added (lithium battery recommended). 1x Filter 2.5mm Allen Key L961 L962 Dual power Input Box Dual power Input Box with 9V Alkaline with 9V transformer battery lovair.com...
  • Page 5: Pre-Installation Information

    Pre - Installation Information Check contents Separate all parts from the packaging and check each part with the “Pack contents” section. Pay attention to the different models variations. Make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not attempt to install your electronic tap until you obtain the missing parts.
  • Page 6: Tap Installation

    Make sure the O-ring is located between the deck or lavatory and the bottom of the tap. O-ring 2. Slide the gasket, washer and hexagonal nut over the flexible hose and secure the tap into place. O-ring O-ring Gasket Gasket Disk Disk lovair.com...
  • Page 7 Tap Installation Step 3 – Connecting the water supply 1. Connect the flexible hose coming from the tap’s base to the solenoid valve housing in the dual power input box. Important: Inlet and outlet should follow the indicating arrow at the solenoid housing 2.
  • Page 8 Connect the transformer into the transformer socket and connect to the electricity socket. 3. In order to avoid entering into the adjusting mode, wait 10 seconds before operating the system. If the range is unsatisfactory, refer to the section titled “settings adjustment”. ABOUT 10 seconds lovair.com...
  • Page 9 Settings Adjustment With Remote Control Adjusting the settings with the remote control If necessary, the sensor settings can be adjusted as following: Shut off the water supply. In order to adjust the sensor with the remote control, hold the remote control straight in front of the sensor in a distance of about 15-20cm (6-8”).
  • Page 10 If required, the delay out time can be modified as follows: Press the OUT button. Wait until a quick flashing of the red light of the sensor eye is perceived. Then, press + to increase the delay out time and – to reduce it. lovair.com...
  • Page 11 Settings Adjustment With Remote Control Comfort Flush: This function is for flushing the tap during maintenance works. This setting is activated by pressing the clock button to make water flow for 2 minutes. After 2 minutes the water will stop. To activate the comfort flush, press the clock button.
  • Page 12: Settings Adjustment

    } will stop flashing. When the red light has turned off, the sensor has been adjusted to the required distance. Check the distance you have set and if it is not satisfactory, repeat steps 1-6. Battery version Transformer version lovair.com...
  • Page 13: Battery Replacement

    Battery Replacement Battery models only When the battery weakens, the red indicator light will blink at a constant rate. The battery must be replaced within two weeks. 1. Carefully open the dual power input box 2. Remove the old battery. using the 2.5mm Allen key provided.
  • Page 14: Spare Parts List

    Battery back-up device - IP67 L06001013 Powersplitter - 2 way L06001010 Powersplitter - 3 way L06009016 Extension cable - 1 metre L06009032 Extension cable - 4 metres If further information is required, contact Lovair technical team for more detailed guidelines. lovair.com...
  • Page 15: Maintenance

    Maintenance Filter cleaning instructions This tap is provided with one / two stainless steel filter(s) preventing foreign particles to enter the lines. If the water flow has decreased, this can be because the filter(s) is/are clogged. The filter(s) can be cleaned as follows: Shut-off the water shut off valve (angle valve).
  • Page 16: Limited Warranty

    If a defect is found in normal use, Lovair Ltd. will, at its discretion, repair, provide a replacement part or product, or make appropriate adjustments. Damage caused by accident, misuse, or abuse is not covered by this warranty.
  • Page 17 The central orifice in the Clean orifice or replace diaphragm is blocked or the diaphragm (Lovair part no diaphragm is damaged. L04500001) The water supply pressure is Reduce water supply pressure. more than 8bar.