mumbi Gas detector m-GM100
User manual
GB
Claus GmbH
Sigsfeldstr. 4
45141 Essen
www.mumbi.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the m-GM100 and is the answer not in the manual?

Questions and answers

Summary of Contents for mumbi m-GM100

  • Page 1 Gas detector m-GM100 User manual Claus GmbH Sigsfeldstr. 4 45141 Essen www.mumbi.de...
  • Page 2: Table Of Contents

    Liquefied petroleum gases ‒ Propane and butane ....6 Maintenance and cleaning / TIP / CAUTION ........ 6-7 Installation and mounting ............7 Protecting the environment ............8 Safety and maintenance advice ..........8 Bedienungsanleitung Mode d‘emploi www.mumbi.de/manuals Istruzioni per l’uso Manual de instrucciones...
  • Page 3: Scope Of Supply / Specifications / General

    User Manual m-GM100 - Gas detector Scope of supply • Gas detector and main power supply unit • 9V block battery • Installation kit and instructions Specifications Adapter: 12V DC / 200mA Warning signal: ≥ 85dB at a distance of 1m Alarm interval: 0.5 sec.
  • Page 4: Natural Gas - Methane

    IMPORTANT: This gas detector has been designed to detect natural and liquefied petroleum gases. The detector is NOT intended for detecting smoke or fire. This gas detector only indicates the presence of gas in the immediate vicinity of the detector. It will not detect gas in other parts of the house or caravan. Natural gas ‒...
  • Page 5: Note

    the LED should switch to a permanent green light. If the alarm signal sounds every 4 seconds, the sensor is defective. Installation of gas detector Attach the mounting ring in the right place using 2 screws. Place detector onto the ring and turn. Ensure that the 2 indentations of the adapter ring are aligned. Connect the mains power supply unit to the detector: this can only be done in one particular way.
  • Page 6: Basic Principles Of An Escape Plan

    Basic principles of an escape plan Draw up a floor plan which includes all doors and windows and the escape routes from each room. Hold a family meeting to discuss the escape plan and tell eveyone what they need to do in the event of an alarm. Specify a location outside of your house as a meeting point in the event of an alarm.
  • Page 7: Installation And Mounting

    The device is maintenance-free, so please do not open up the gas detector. You will invalidate your warranty if you open up the device. Clean the outside of the gas detector with a soft, dry cloth or a brush. Do not use any cleaning products that contain carbonic acid, benzene, alcohol or similar substances.
  • Page 8: Protecting The Environment

    MINIMUM DISTANCE OF AT LEAST 3 METRES during installation and operation. Claus GmbH Sigsfeldstr. 4 45141 Essen www.mumbi.de EN50194:2000 Manufactured for Smartwares Safety & Lighting BV Broekakkerweg 15, 5126BD Gilze The Netherlands +49(0)1805010762, www.smartwares.eu Imported for Claus GmbH, Sigsfeldstraße 4 45141 Essen, Deutschland, www.mumbi.de...