Datalogic DWS-SWITCH-MONO Installation Manual
Datalogic DWS-SWITCH-MONO Installation Manual

Datalogic DWS-SWITCH-MONO Installation Manual

Ac power disconnector and distributor

Advertisement

Quick Links

L
DWS-SWITCH-MONO
INSTALLATION MANUAL
AC Power Disconnector and Distributor

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic DWS-SWITCH-MONO

  • Page 1 DWS-SWITCH-MONO INSTALLATION MANUAL AC Power Disconnector and Distributor...
  • Page 2 Datalogic publications, please let us know via the "Contact" page. Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is complete and accu- rate, however, Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.
  • Page 3: Table Of Contents

    Cabinet Mounting ......................2 System Wiring: AC Output ....................3 System Wiring: OUT#1 and OUT#2 .....................3 System Wiring: OUT#3 ........................4 System Wiring: OUT#4 ........................4 System Wiring: AC Input ....................5 DWS-SWITCH-MONO Electrical Diagram ................6 CHAPTER 3. TECHNICAL FEATURES ................. 7 INSTALLATION MANUAL...
  • Page 4: Preface

    TECHNICAL SUPPORT Support Through the Website Datalogic provides several services as well as technical support through its website. Log on to (www.datalogic.com). For quick access, from the home page click on the search icon , and type in the name of the product you’re looking for.
  • Page 5: Safety Regulations

    Datalogic commercial reference contacts. Since April 20th, 2016 the main European directives applicable to Datalogic products require inclusion of an adequate analysis and assess- ment of the risk(s). This evaluation was carried out in relation to the applicable points of the standards listed in the Declaration of Conformity.
  • Page 6: General View

    PREFACE GENERAL VIEW Figure 2 - DWS-SWITCH-MONO General View 1 Key Lock 5 AC Ouput Cable Compression Connectors 2 Main Switch 6 AC Line Input Terminals and Protection Earth 3 Product Data Label 7 AC Line Fuses 4 AC Input Cable Compression Connector...
  • Page 7: Chapter 1. Introduction

    CHAPTER 1 INTRODUCTION The DWS-SWITCH-MONO is an AC Power Disconnector and Distributor cabinet that can be used as first functional block in Dimensioning, Weighting and Barcode Scanning (DWS) systems. This document describes the DWS-SWITCH-MONO used to power a system composed of four electrical loads: a Datalogic PWR-480W electrical panel, a Scale (digital section), a Datalogic PWR-2400 electrical panel and a Datalogic PWR-480B, PWR-240B;...
  • Page 8: Chapter 2. Installation

    Figure 3 - Mounting Brackets IMPORTANT: The cabinet must be installed vertically in such a way that the main switch is no higher than 1.90 m from the ground (see Figure below). Figure 4 - DWS-SWITCH-MONO cabinet max. height DWS-SWITCH-MONO...
  • Page 9: System Wiring: Ac Output

    SYSTEM WIRING: AC OUTPUT Please note that the cabinet door can be unlocked and opened by using the key pro- vided along with the product HIGH VOLTAGE: When the main switch is in the OFF position, the outputs #1, #2, and #3 are disconnected, but not the AC Line Input Terminals! SYSTEM WIRING: AC OUTPUT System Wiring: OUT#1 and OUT#2 Figure 5 - Terminal Block for Out#1 and Out#2...
  • Page 10: System Wiring: Out#3

    , where "yy" is a value between 2.5 - 4 mm Out#4 is protected by Fuse QF03, 4A gG. CAUTION: Output cables can be max. 12 m long. NOTE: When not used, keep the compression connectors sealed with their appropriate plugs. DWS-SWITCH-MONO...
  • Page 11: System Wiring: Ac Input

    Figure 8 - AC Input cable entry The Cable Entry Compression Connector has protection capability of IP65. For external 230 Vac power supply to the DWS-SWITCH-MONO use a 3-conductor cable with size of 4 mm Follow the procedure below to wire the AC input line.
  • Page 12: Dws-Switch-Mono Electrical Diagram

    INSTALLATION DWS-SWITCH-MONO ELECTRICAL DIAGRAM The DWS-SWITCH-MONO components are electrically connected as displayed in the fol- lowing diagram: Figure 9 - DWS-SWITCH-MONO Electrical Diagram (Drawing Number GEL-9620) DWS-SWITCH-MONO...
  • Page 13: Chapter 3. Technical Features

    CHAPTER 3 TECHNICAL FEATURES ELECTRICAL FEATURES Input 230 V 1~ 50 Hz; I max 28 A Icp 10kA 230 V 1~ 50 Hz; I max 16 A Output 230 V 1~ 50 Hz; I max 8 A 230 V 1~ 50 Hz; I max 4 A ENVIRONMENTAL FEATURES Operating Temperature 0 to +50 °C (+32 to +122 °F)
  • Page 14 © 2018-2022 Datalogic S.p.A. and /or its affiliates • All rights reserved • Without limiting the rights under copyright, no part of this documentation may be repro- duced, stored in or introduced into a retrieval system, or transmitted in any form or by any means, or for any purpose, without the express written permission of Data- logic S.p.A.