Page 2
Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. Manufacturer Edwards, A Division of UTC Fire & Security Americas Corporation, Inc. 8985 Town Center Parkway, Bradenton, FL 34202, USA. FCC compliance This device complies with part 15 of the FCC Rules.
Setting up monitors 16 Connecting printers 19 Connecting AC power 20 Installing the FireWorks UL5W7 workstation on a desk or bench 22 Installing the FireWorks UL5W7 workstation in a rack 24 Control panel RS-232 wiring connections 26 ...
Page 4
Appendix A Calculations 55 UPS sizing calculations 56 Attenuation worksheet 59 Appendix B Listing requirements 61 Listing requirements 62 Index 65 FireWorks UL5W7 Workstation Installation Manual...
Because some jurisdictions do not FireWorks UL5W7 Workstation Installation Manual...
Page 6
Note: Note messages advise you of the possible loss of time or effort. They describe how to avoid the loss. Notes are also used to point out important information that you should read. FireWorks UL5W7 Workstation Installation Manual...
Chapter 1 Introduction Summary This chapter provides a brief introduction to the FireWorks UL5W7 workstation, and summarizes listing requirements. Content About this manual 2 About FireWorks 2 About the FireWorks UL5W7 workstation 3 Front panel features 3 ...
Chapter 1: Introduction About this manual This manual is for the FireWorks UL5W7 workstation models described below. Model Description FWUL5W7 Workstation, Intel Core 2 Duo CPU, 500 GB hard drive, DVD drive, 4 GB RAM (8 GB max.), Windows 7 Ultimate OS...
Chapter 1: Introduction About the FireWorks UL5W7 workstation Front panel features Figure 1: Front panel features (2) (3) (4) (5) (12) (11) (10) (1) ON/OFF key switch (7) DVD drive OPEN/CLOSE button (2) USB connectors (8) DVD drive LED (3) Trouble LED...
FireWorks project. See “Setting up monitors” on page 16 for (10) Ethernet connectors (2X), not used more information. (11) Rear fan (Fan 4) (6) Audio connectors, not used (12) Analog (VGA) output (7) Not used FireWorks UL5W7 Workstation Installation Manual...
(1) Power Supply fan (Fan 8) (5) Front fan (Fan 2) (2) Rear fan (Fan 4) (6) CPU fan (Fan 1) (3) Front trouble LED (7) Power connection from workstation power supply (4) Front fan (Fan 3) FireWorks UL5W7 Workstation Installation Manual...
Chapter 1: Introduction Memory configuration FireWorks UL5W7 workstations support dual channel memory configurations. Single channel memory configurations and mismatched memory are not supported. Install memory only as shown below. See Figure 3 on page 5 for memory slot locations. Table 1: Supported memory configurations...
Page 14
FW-42LCDHMK1 Wall mount bracket kit, single 42-inch LCD monitor, horizontal FW-42LCDVMK1 Wall mount bracket kit, single 42-inch LCD monitor, vertical FW-42LCDVMK2 Wall mount bracket kit, dual 42-inch LCD monitor, vertical RKU-61-24B Cabinet, 19 inch, rack-mount FireWorks UL5W7 Workstation Installation Manual...
Setting up monitors 16 Connecting printers 19 Connecting AC power 20 Installing the FireWorks UL5W7 workstation on a desk or bench 22 Installing the FireWorks UL5W7 workstation in a rack 24 Control panel RS-232 wiring connections 26 ...
3. Install the workstation. For instructions, see “Installing the FireWorks UL5W7 workstation on a desk or bench” on page 22 or “Installing the FireWorks UL5W7 workstation in a rack” on page 24. 4. Connect the monitors, keyboard, and mouse. See “Quick setup” on page 12.
PCI card slots. To install an option card: 1. Turn off the FireWorks UL5W7 workstation and disconnect AC power. 2. Remove the workstation cover and the card hold-down bracket. 3. Locate the appropriate PCI slot. See Figure 6 above.