Download Print this page
F&F FOX ENERGY 3 Mounting Instructions

F&F FOX ENERGY 3 Mounting Instructions

3-phase energy consumption monitor

Advertisement

Quick Links

F&F Filipowski sp. j.; Konstantynowska 79/81, 95-200 Pabianice, POLAND
www.fif.com.pl; e-mail: biuro@fif.com.pl
Application
» Monitoring of energy consumption in domestic installations;
» Ongoing measurement of power consumption and values of
currents and voltages;
» Use of recorded measurements to detect exceedances in vol-
tage levels or power consumption;
» Controlling energy production in photovoltaic installations;
» Metering of heat pumps.
www.fif.com.pl/fox/energy3
ENERGY 3
energy consumption monitor
- 1 -
Wi-MEF-3
3-phase

Advertisement

loading

Summary of Contents for F&F FOX ENERGY 3

  • Page 1 ENERGY 3 Wi-MEF-3 3-phase energy consumption monitor www.fif.com.pl/fox/energy3 F&F Filipowski sp. j.; Konstantynowska 79/81, 95-200 Pabianice, POLAND www.fif.com.pl; e-mail: biuro@fif.com.pl Application » Monitoring of energy consumption in domestic installations; » Ongoing measurement of power consumption and values of currents and voltages; »...
  • Page 2 Properties » 3-phase, 2-way, 4-quadrant electricity consumption monitor, perfect for monitoring photovoltaic installations, among other things; » Monitoring of all relevant electrical network parameters; » Recording of average, minimum and maximum values; » Non-invasive installation using miniature (26×26×40 mm) cu- rrent transformers;...
  • Page 3 Configuration For the initial configuration of the Fox module, it is necessary to download and run the free Fox application available for mobile devices running the system: » Android, version 6.0 or higher; » iOS, version 12 or higher. You can download the app directly from the stores: or via the website: www.fif.com.pl/fox On the above page, you can also find detailed information on...
  • Page 4: Wiring Diagram

    Wiring diagram - 4 -...
  • Page 5 Description of terminals Power supply and voltage measurement (top row of terminals) L1 phase L2 phase L3 phase neutral wire Connecting the phase wire to the N terminal may damage the device. Measuring transformers (bottom row of terminals) Terminals intended only for connecting current trans- formers supplied with the meter.
  • Page 6 Mounting of measuring transformers Miniature, open-ended current transformers are supplied with the unit. No interference with the current leads is required to clip them onto the measured leads, but special attention must be paid to the way the lead is passed through the transformer and to the connection of the secondary side of the transformer to the device.
  • Page 7: First Launch

    First launch After connecting the device to the power supply, it is recommen- ded to personalize the device. Personalization is the process of assigning passwords to access the device and setting up a con- nection to the home Wi-Fi network and (optionally) remote ac- cess to the device via the F&F cloud.
  • Page 8 – Remote access Remote access configuration is necessary when you need to be able to access and control your Fox devices from outside your home when your phone app and Fox modu- les are not connected to the same local network. If you do not have a remote access account, create one by pres- sing Create Account button and following the instructions displayed by the application.
  • Page 9 – Password manager Each Fox device allows you to enter two passwords: an administrator who has full configuration and device con- trol rights, and a user who can control devices but without access to configuration settings. First, add passwords to the password manager. One or two predefined passwords are then substituted for the personalized controllers.
  • Page 10 Deleting a password from the Password Manager will lose access to all devices using the deleted password. – Search Based on the previously entered information (remote ac- cess and password list), the application will start searching for devices. Before you start searching, you need to enable the Blu- etooth function on your phone and agree to access the location.
  • Page 11 Pressing the "+" button adds device support to the appli- cation. For controllers in factory mode, the customization mechanism for the selected module is started here and the instructions in the Device Configuration window must be followed: › Enter the name under which the device will be display- ›...
  • Page 12 (passwords, Wi-Fi settings, remote access, calendar, location and time zone) into the new device. Telemetry Fox Energy 3 allows energy consumption and monitored ne- twork parameters to be recorded. Data can be accessed directly from the application (Telemetry command visible in the device context menu) or via any web browser.
  • Page 13 Energy consumption data will be stored in the database for a minimum of 10 years, after which they will be overwritten by more recent readings. Other network parameters (voltages, currents, powers) will be stored in the database for a minimum of 3 months, after which they will be overwritten by more recent readings.
  • Page 14: Restore Factory Settings

    LED signalling cont. No connection to Wi-Fi network Restoring firmware Energy consumption signalling Three LED lights (L1, L2, L3) on the front of the unit on the ri- ght-hand side are used to indicate the presence of voltage and power consumption. A light on indicates the presence of voltage on a given measuring circuit.
  • Page 15 2. After about 5 seconds, the green LED (STATUS) will turn off and you should release the RESET button. 3. Press the RESET button briefly, the green LED (STATUS) will light up again. 4. Press and hold down the RESET button. After about 3 seconds, the previously switched on green LED (STATUS) will start to flash.
  • Page 16: Warranty

    communication radio frequency 2.4 GHz transmission Wi-Fi radio power (IEEE 802.11n) <13 dBm receiver sensitivity -98 dBm terminal 2.5 mm² screw terminals (cord) 4.0 mm² screw terminals (wire) tightening torque 0.5 Nm working temperature -20÷50°C humidity <90% (no condensation of steam and aggressive gases) dimensions 2 modules (35 mm) mounting...

This manual is also suitable for:

Wi-mef-35902431675251