Omega LCWD Series Instruction Sheet page 2

Load washer & compression load cells

Advertisement

DIMENSIONS
O.D.
H
INSTALLATION SCHEMATIC
RADIUS
HOW LOAD CELLS WORK
Load cells have an output or sensitivity in mV/V. What this sensitivity/output represents is as follows:
Change in millivolt output
from zero load to the full
scale capacity of the load cell
(21.3 mV in this example)
No load cell has exactly zero millivolts at no load. Most cells have a small millivolt DC offset of a few millivolts
which is normal. To scale a system the end user just scales his recorder/meter for a full scale change of (21.3 mV
per example), and connects the load cell in a no load situation and rezeros the pens/display for a correct zero
reading.
WIRING DIAGRAM
10 VDC REGULATED
POWER SUPPLY
+
+
METER
BLACK -EXC
GREEN +OUT
WHITE -OUT
I.D.
CABLE
H
BUTTON
T
LOAD CELL
H
BUTTON
= output/sensitivity x excitation
(2.13 mV/V)
RED (+EXC)
BLACK (–EXC)
GREEN (+SIG)
WHITE (–SIG)
TYPICAL EXAMPLE
BOLT
SPHERICAL WASHER
LOAD CELL
FLAT WASHER
STRUCTURE
STRUCTURE
(10.0 VDC)
WASHER
LOAD CELL
BOLT
SPHERICAL
WASHER SET
LOAD CELL
FLAT WASHER
(NOT INCLUDED)