Advertisement

YPK6S-08C
Portable Air Conditioner
User Manual
Thanks for choosing this superb air conditioner.
Please read carefully this manual before using.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the YPK6S-08C and is the answer not in the manual?

Questions and answers

Lawrence Brannon
June 9, 2025

what does "dry" mean on the push buttons?

1 comments:
Mr. Anderson
June 9, 2025

On the DOKO YPK6S-08C push buttons, "dry" refers to a mode you can select using the Mode Button. It is one of the operating modes along with cooling and fan. The "dry" mode is typically used for dehumidifying the air.

This answer is automatically generated

Allen Riddle
May 25, 2025

I need to order the air exhaust duct assembly and the air flow interface unit.

K Sharp
April 21, 2025

How to clean coils?

Summary of Contents for DOKO YPK6S-08C

  • Page 1 YPK6S-08C Portable Air Conditioner User Manual Thanks for choosing this superb air conditioner. Please read carefully this manual before using.
  • Page 2: Table Of Contents

    CONTENTS IMPORTANT SAFETY INFORMATION IMPORTANT SAFETY INSTRUCTIONS User Tips Precautions Safety Warnings Tips Product Overview Main Components Control Panel and Remote Control Operation Place and Install How to Operate Clean and Maintenance Drainage Body Clean Common Failures and Diagnosis Intelligent Error Detection Troubleshooting...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORTANT SAFETY INSTRUCTIONS WARNING • Don't spatter water or oil into machine. • This machine just for domestic use, please don't use it in any other places. • Don't put hard objects between fan blades. •...
  • Page 4: User Tips

    USER TIPS Please avoid such operations, in case of any safety and health risks. Such instructions are to be followed, for safety and health concerns. PRECAUTION For indoor use only; For household use only please place the A/C in a dry environment.
  • Page 5 Do not operate the machine Please wipe the machine with a with wet hands or in a humid soft cloth, instead of wax, diluent environment. or irritant detergent. Clean the filter once every two For your health, never drink weeks condensed water discharged from the machine.
  • Page 6: Safety Warnings

    SAFETY WARNINGS Damaged power cord or plug Never damage the power cord, or shall not be used. Never plug use unlicensed power cord. Make to a loose socket. sure voltage is right. Do not modify or extend the A grounded outlet is suggested power cord.
  • Page 7 Never control on/off status by Please turn off the machine directly plugging/unplugging. before unplugging. Keep away from heat sources Never overload the socket. or direct sunlight exposure. If there is any actue noise, In case of electric shock, never smell or smoke, turn off and damage the power cord by unplug for diagnosis.
  • Page 8 Never insert fingers or any Keep electrical parts away from hard objects into the louver. water. If water enters, turn off and unplug Please turn off and unplug before in time; and call for check and wiping, cleaning or replacing repair from a professional.
  • Page 9: Tips

    TIPS For a proper work of compressor, For a proper ventilation, keep the machine at least 19.7inch place the machine vertically on an even ground. from objects nearby. Never use the appliance near Keep the appliance from spraying gasoline or other flammable agent or any solvent,...
  • Page 10: Product Overview

    PRODUCT OVERVIEW Main Components 1. Handle 2. Air Inlet Grille (Up) 3. Control Panel 4. Casters 5. Louver 6. Air Outlet Grille 7. Drainage Hole 8. Air Inlet Grille (Down) 9. Air Exhaust Duct Assembly 10. Window Sealing Kit...
  • Page 11: Control Panel And Remote Control

    CONTROL PANEL AND REMOTE CONTROL 1. Power Button Press the button to turn on/off machine. 2. Fan Speed Button Press the key to choose high/low speed. 3. UP/Down Button for Temperature and Timer Under cooling mode, press the keys could increase or decrease setting temperature;...
  • Page 12: Operation

    OPERATION Place & Install Best Install Place • Place the machine on the horizontal floor near the window. • For proper ventilation and best machine performance, keep the appliance at least 19.7inch from objects nearby. 19.7inch Install Air Exhaust Duct Assembly Connector Air exhaust duct Flat nozzle...
  • Page 13 Step 1: Clip-fixture Type 1. Measure window size; 2. Adjust Length of the plate according to window size; 3. Lock the plate Step 2: Fix the plate to window Step 3: Swirl the exhaust pipe assembly (exhaust fitting end) into the rear panel outlet (counterclockwise).
  • Page 14 little breach screw 1.Plug in first Step 4: Insert the exhaust pipe assembly (exhaust port end) into the window seal panel assembly and screw it up. Impression Drawing of Completion...
  • Page 15 Incorrect installation • Free access of exhaust pipe is important, installation errors will bring bad in uence of machine. • Avoid exhaust-pipe with sharp bend. • Make sure air in exhaust pipe can run smoothly. Warning Length of exhaust pipe according to the machine features, please don't replace or lengthen it freely, otherwise errors will be easily caused.
  • Page 16: How To Operate

    Warning: 1. Never use leaked batteries; 2. Chemicals in batteries could result in such health hazards as burns. If liquid in batteries splashes to skin or clothes, please wash with clean water in time. If batteries are swallowed, please rinse mouth immediately with clean water and then go to the doctor.
  • Page 17: Clean And Maintenance Drainage

    TIMER MODE • Under standby mode, press “TIMER” to setup the power-on time. Timer indicator turns on. • Under power-on mode, press “TIMER" to setup power-off timer. Timer indicator turns on. CLEAN AND MAINTENANCE Drainage With self-evaporating system, the appliance could perform better and save energy in a way of cooling down condensor by reusing condense water.
  • Page 18 Clean the filters every two weeks, if filters are blocked by dust, machine efficiency will be reduced. Take off air-inlet grille as indicated in the photo; pull out the filters. Clean the filter in 40°C or 104°F warm water or water with neutral detergent; dry the filter in a cooling area.
  • Page 19: Common Failures And Diagnosis Intelligent Error Detection

    Seasonal Maintenance If the appliance will not be in use for a long time, please maintain by following below steps: 1. Pull out drainage plug to ow out water. 2. . Let the machine runs under fan mode f 2 hours to dry out the machine internal. 3.
  • Page 20: Troubleshooting

    TROUBLESHOOTING Please contact professional serviceman without delay in following situation. Note: when abnormal situations are occurred, turn off machine and pull out plug, then contact with professional electrician for help. TROUBLE CAUSE SOLUTION Reset circuit breaker on AC cord No display The A/C doesn’t Restart the A/C after power off...
  • Page 21 Company: JINGMEIRUI TRADE LIMITED Email: support@dokoelectronics.com Website: www.dokoelectronics.com...

Table of Contents

Save PDF