Growatt ATS-US Series Quick Start Manual
Growatt ATS-US Series Quick Start Manual

Growatt ATS-US Series Quick Start Manual

Advertisement

Quick Links

1.

Introduction

The Auto Transfer Transformer (ATS-US) controls the switch of the contactors to provide power to the critical load stated as EPS Emergency
Power Supply load in both grid-tied and off-grid conditions. There is a contactor in ATS-US to provide user a simple connection. ATS-US is
operating with PCS inverter for the purpose of providing the split phase power when grid accidentally or unexpectedly goes off. This
approach allows the home critical contunously to be supplied.
2.
The location of ATS-US in the system
Hybrid Inverter
PV Array
Battery
EPS
Grid
RSD1
DC
Breaker
Breaker
ATSE
AC
Electrical Grid
Breaker
AC
Breaker
Sensor
Load
EPS
Load
As shown in chart 2.1, the input side of ATS-US is connected with
EPS output of hybrid inverter and grid, the output side is
connected with critical load stated as EPS load. EPS Load is set
default to connect with Grid power.If Grid is lost, EPS Load will
turn the switch to EPS output of hybrid inverter. And there is a
transformer in ATS-US, it can transform 240V to 120/240V split
phase to provide the power to critical load.
4.

General Information - Parts List

5.
Dimension & Weight
ATS -US Series Quick Guide
3.
Configuration
Model name
ATS-US
Grid Rated Voltage
240V
Grid Rated Frequency
50 /60Hz
a
Grid Rated Current
21 a.c.A ,48 a.c.A
EPS Rated Voltage
240V
EPS Rated Frequency
50 /60Hz
a
EPS Rated Current
21 a.c.A,48 a.c.A
Load Rated Voltage
120/240V
a
Load Rated Current
21 a.c.A,48 a.c.A
a
Load Rated power(L-L)
5000VA,11400VA
a
Load Rated balanced power(L-N)
5000VA,11400VA
Load Rated unbalanced power(L-N)
3000W
Cooling Concept
Natural
Ingress Protection
IP65/NEMA type 4X
Installation
Wall Mountable
-25℃~+50℃(-13 to+122°F)
Operation Ambient Temperature
Weight
15.6kg/34.3lb
Size
480*275*105mm/18.9*10.8*4.1in
以上图形a代表ATS 5000T-US,b代表ATS 11400T-US
Above a:ATS 5000T-US,b:ATS 11400T-US
Part List
Item
Item Name
Qty
Item
Item Name
ATS-US (Auto
Transfer
A
1
E
Fixing screws
Transformer)
B
User Manual
1
/
/
C
Anchor Bolt
3
/
/
D
Key
2
/
/
Dimension (L x W x H): 480*275*105mm/18.9*10.8*4.1in
Weight: 15.6KG/34.3lb
6.

Tools

b
7.

Wall Mount Installation

b
b
b
b
(A)
Qty
2
/
(E)
/
8.

Open the ATS-US

/
NO.
1
Press terminal connector
2
3
4
(B)
(C)
a. Please reserve the space of 300mm (11.81in) from ATS-US.
b. Place the wall bracket horizontally on the wall and mark the
position of 3 holes for screws.
c. Remove the wall mount and drill 3 holes were marked, Drill
holes with φ10 drill Depth: at least 40mm (1.575in).
d. First knock expansion pipe into the hole with Rubber
hammer
and then place the wall bracket align with the marked
position on the wall. Last, screw the self-tapping screwing into
the expansion pipe.
e. Tighten the screws on both sides of the wall bracket.
As shown above, please put the key into the Keyhole on the ATS-
US top right and bottom right and clockwise rotation to 90°.The
cover can be opended. Rotate 90 ° counterclockwise to remove the
key. The cover can be pressed directly to close the cover.
Description
Screw driver
Knock explosion bolt
Drill holes on the wall
(D)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ATS-US Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Growatt ATS-US Series

  • Page 1 ATS -US Series Quick Guide Introduction Tools The Auto Transfer Transformer (ATS-US) controls the switch of the contactors to provide power to the critical load stated as EPS Emergency Description Power Supply load in both grid-tied and off-grid conditions. There is a contactor in ATS-US to provide user a simple connection. ATS-US is operating with PCS inverter for the purpose of providing the split phase power when grid accidentally or unexpectedly goes off.
  • Page 2 6. Repair is to be performed only by qualified technical personal authorized by manufacturer. The rated balanced power(L-N)means the Load of L1-N and L2-N is equal. Growatt New Energy Download The rated unbalanced power(L-N)means the load of L1-N and L2-N is different.

This manual is also suitable for:

Ats 11400t-us

Table of Contents