TDK-Lambda DTM160 Series Instruction Manual
TDK-Lambda DTM160 Series Instruction Manual

TDK-Lambda DTM160 Series Instruction Manual

External ac-dc power adapters, 160w

Advertisement

Quick Links

DTM160, DTM160-C8 Manual
External AC-DC Power Adapters, 160W
Content:
1.
Product Description.............................................2
2.
Product Features .................................................2
3.
Intended Use .......................................................3
4.
Installation Instructions ......................................3
5.
6.
Functional Description ........................................4
7.
Functional Diagram.............................................4
8.
9.
Short-form Data ..................................................6
10. Efficiency Curves..................................................7
11. EMC......................................................................8
13. Environment ......................................................10
15. Safety and Protection Features ........................11
17. Packaging Information .....................................13
All parameters are typical values specified at nominal input voltage, nominal output load, 25°C ambient and after a 5 minutes run-in time unless
otherwise noted. The information presented in this document is believed to be accurate and reliable and may change without notice.
For additional information, please visit
DTM160 Series (Class I)
DTM160-C8 Series (Class II)
Instruction and Application Manual
https://product.tdk.com/en/power/dtm
DOC-ID: 260933 - Issue 1
1/13

Advertisement

Table of Contents
loading

Summary of Contents for TDK-Lambda DTM160 Series

  • Page 1: Table Of Contents

    DTM160, DTM160-C8 Manual External AC-DC Power Adapters, 160W DTM160 Series (Class I) DTM160-C8 Series (Class II) Instruction and Application Manual Content: Product Description..........2 Product Features ..........2 Intended Use ............3 Installation Instructions ........3 Recycling and Disposal Information ....4 Functional Description ........4 Functional Diagram..........4...
  • Page 2: Product Description

    1. P RODUCT ESCRIPTION With the two series DTM160 and DTM160-C8 TDK-Lambda offers compact 150-160W medical AC-DC power adapters. Both, the DTM160 as a Class I version with protective earth on the input and the DTM160-C8 as Class II version with double insulated protection uses a robust desktop housing with the dimensions of only 150 x 70 x 38mm.
  • Page 3: Intended Use

    Do not use this device as critical component in nuclear control systems, life support systems or equipment for use in hazardous environments without the express written approval of TDK-Lambda. If this device is used in a manner outside of its specification, the protection provided by the device may be impaired.
  • Page 4: Recycling And Disposal Information

    DTM160, DTM160-C8 Manual External AC-DC Power Adapters, 160W 5. R ECYCLING AND ISPOSAL NFORMATION The device may not be disposed of as domestic refuse. Packaging and packaging aids must be recycled or disposed in accordance with local regulations. 6. F UNCTIONAL ESCRIPTION The output is electronically protected against no-load, overload and short circuit.
  • Page 5: Product Nomenclature And List Of Models

    DTM160, DTM160-C8 Manual External AC-DC Power Adapters, 160W 8. P RODUCT OMENCLATURE AND IST OF ODELS Product Nomenclature: Family Name Power Class Place of Output Voltage CLASS I / II Manufactoring 160 = 160W (Code) 120 = 12V Blank = Class I 240 = 24V C8 = Class II 360 = 36V...
  • Page 6: Short-Form Data

    DTM160, DTM160-C8 Manual External AC-DC Power Adapters, 160W 9. S HORT FORM Input voltage Nom. AC 100-240V Input voltage range 80 – 264Vac Reduce output power below 90VAac (Note: Safety certified for 90-264Vac only) Input voltage frequency range 47 – 63Hz Input current Max.
  • Page 7: Efficiency Curves

    DTM160, DTM160-C8 Manual External AC-DC Power Adapters, 160W Allowed Output Load 160W 128W 1: Input voltage 90-264Vac 2: Input voltage 80-90Vac 70°C Ambient Temperature 10. E FFICIENCY URVES DTM160CN120, DTM160CN120C8: DTM160CN240, DTM160CN240C8: Efficiency vs. output load Efficiency vs. output load DTM160CN360, DTM160CN360C8: DTM160CN480, DTM160CN480C8: Efficiency vs.
  • Page 8: 11. Emc

    DTM160, DTM160-C8 Manual External AC-DC Power Adapters, 160W 11. EMC The EMC behavior of the device is designed for applications in industrial environment as well as in residential, commercial and light industry environments. The device is investigated according to EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 and EN 60601-1-2.
  • Page 9: Physical Dimensions, Weight And Connectors

    DTM160, DTM160-C8 Manual External AC-DC Power Adapters, 160W 12. P HYSICAL IMENSIONS EIGHT AND ONNECTORS Length 150mm (5.91’’) Width 70mm (2.76’’) Height 38mm (1.50’’) Weight 575g (1.27lb) Case material Polycarbonate DTM160: DTM160-C8: All dimensions in mm Wire Size For models 950mm 16AWG 1800mm...
  • Page 10: Environment

    DTM160, DTM160-C8 Manual External AC-DC Power Adapters, 160W 13. E NVIRONMENT Operational temperature -20°C to +70°C Operational temperature is the ambient or surrounding (-4°F to 158°F) temperature of the device Storage temperature -40°C to +85°C For storage and transportation (-40°F to 185°F) Output de-rating 4.3W/°C Between +40°C and +70°C...
  • Page 11: Isolation And Dielectric Strength

    DTM160, DTM160-C8 Manual External AC-DC Power Adapters, 160W 14. I SOLATION AND IELECTRIC TRENGTH The output voltage is floating and has no ohmic DTM160: DTM160-C8: connection to the input or PE. Input Input Output Hi-pot tests may be repeated by the customer using appropriate test equipment, which applies the voltage Output with a slow ramp (2s up and 2s down).
  • Page 12: Approvals And Regulatory Compliances

    DTM160, DTM160-C8 Manual External AC-DC Power Adapters, 160W 16. A PPROVALS AND EGULATORY OMPLIANCES EU Declaration of Conformity includes Low-Voltage, EMC and RoHS Directive UKCA UK Declaration of Conformity includes Electrical Safety, EMC and RoHS Directive UL 60601-1:ED3 UL Certificate Recognized component for category QQHM2 and QQHM8 - Medical electrical equipment Applicable for US and Canada...
  • Page 13: Packaging Information

    DTM160, DTM160-C8 Manual External AC-DC Power Adapters, 160W 17. P ACKAGING NFORMATION Product 150x70x38mm 30pcs Inner Box 185x110x50mm 30pcs Plastic Bag 155x245x0.08mm 30pcs Cardboard Box 385x345x280mm 1pcs Net weight 17.1kg Gross weight 18.5kg All parameters are typical values specified at nominal input voltage, nominal output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.