5 Unit installation
a
a
Front panel shaft
5.2.2

To re-install the front panel

1 Attach the front panel. Align the shafts with the slots and push
them all the way in.
2 Close the front panel slowly; press at both sides and at the
centre.
5.2.3

To remove the front grille

CAUTION
Wear adequate personal protective equipment (protective
gloves, safety glasses,...) when installing, maintaining or
servicing the system.
1 Remove the front panel to remove the air filter.
2 Remove 2 screws from the front grille.
3 Push down the 3 upper hooks marked with a symbol with 3
circles.
b
a
a
Upper hook
b
Symbol with 3 circles
4 We recommend opening the flap before removing the front
grille.
5 Place both hands under the centre of the front grille, push it up
and then toward you.
5.2.4

To re-install the front grille

1 Install the front grille and firmly engage the 3 upper hooks.
2 Install 2 screws back on the front grille.
3 Install the air filter and then mount the front panel.
Installation manual
8
5.2.5
1 Remove the front grille.
2 Remove 1 screw from the electrical wiring box.
3 Open the electrical wiring box cover by pulling the protruding
part on the top of the cover.
4 Unhook the tab on the bottom and remove the electrical wiring
box cover.
c
5.2.6
1 Remove 1 screw from the service cover.
a
2 Pull out the service cover horizontally away from the unit.
5.3
5.3.1
1 Install the mounting plate temporarily.
2 Level the mounting plate.
3 Mark the centres of the drilling points on the wall using a tape
measure. Position the end of tape measure at symbol " ".
4 Finish the installation by securing the mounting plate on the wall
using M4×25L screws (field supply).

To remove the electrical wiring box cover

a
b
a
a
Tab
b
Protruding part on the top of the cover
c
Screw

To open the service cover

a
b
a
Service cover screw
b
Service cover

Mounting the indoor unit

To install the mounting plate

INFORMATION
The removed pipe port cover can be kept in the mounting
plate pocket.
3
a
ATXF20~42E5V1B
Daikin room air conditioner
3P650253-11H – 2022.10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Atxf25e5v1bAtxf35e5v1bAtxf42e5v1b