Controller Installation
24 VAC
24VAC
AC PWR
Power Input
24VAC
24V
GROUND
GND
Plug-In LON
Mainentance Port
LON+
FTT
LON-
LON Port
LON
TB2
ANALOG
OUT
AO-1
Analog
AO-2
Outputs
AO-3
AO-4
GND
I/STAT Port
STAT
SIG
SIGNAL
12V
POWER
GND
GROUND
INPUTS
INPUT 1
INPUT 2
INPUT 3
Universal
INPUT 4
Inputs
+24V
GROUND
DIN Rail
Mounting
Clip
Figure 1. NP-546A-X1 (Covered)
Installation Notes:
•
Check the mounting location for the NP-546A-X1. The available
area must measure at least 4.3" × 8" (11 × 20.3 cm) and should be
in a moisture-free container away from any large electrical devices.
The screw holes are 3.75" × 7.5" (9.5 × 19.1 cm) as shown in
Figure
1, and will require phillips or slotted pan head screws.
•
The onboard velocity sensor requires that you install the controller
within four feet of the pickup probe in the air inlet duct of the VAV
box.
•
T
he onboard velocity sensor also requires that you mount the
Connecting Analog 0–10 VDC Output Devices
LON
TB2
ANALOG
OUT
AO-1
AO-2
0–10 VDC
Analog Input
AO-3
Actuator
AO-4
GND
Figure 3. Output Device Connections
Installation Sheet
3.75 "
(9.5 cm)
LED
Communications
Indicators
TRANSMIT
TX
D1
RECEIVE
RX
D2
Output Indicator
OUTPUT 1
1
OUTPUT 2
LEDs
2
OUTPUT 3
3
OUTPUT 4
4
OUTPUT 5
5
OUTPUT 6
6
8.00 "
7
8
20.3 cm
POWER
PWR
SERVICE
SVC
N1831
MODEL:
LED
SERIAL NO.:
POWER:
Service Request
24V ~ 14VA
(62 VA MAX)
Push Button
MADE IN USA
GROUND
BY:
CONTROL
OUTPUT 6
SYSTEMS
INTERNATIONAL
OUTPUT 5
P.O. BOX 59469
DALLAS, TX
OUTPUT 4
Triac Control
75229
OUTPUT 3
Outputs
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS
OUTPUT 2
1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND
2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED
OPERATION.
OUTPUT 1
607573-0006
4.30 "
(11 cm)
LON+
LON-
AO-1
AO-2
AO-3
AO-4
GND
NetPoint General Purpose Unit 546A-X1
(
)
NP-546A-X1
.
24 VAC Power Input
LON Port
I/Stat Port
Figure 2. NP-546A-X1 (Cover Removed)
controller on a vertical surface. Installing the controller with the
barb fittings of the velocity sensor pointing down will help prevent
condensate from migrating into the onboard sensor.
•
You will not need to remove the plastic cover to install the NP-
546A-X1, or any of the connections. To replace the 4A FB fuse,
remove the plastic cover, remove the old fuse and install a new fuse
(see
Figure
2)
1. Connect the analog device to TB3-1 through TB3-4 (AO1 to AO4,
see
Figure
3).
2. Connect the ground wire of the device to the signal ground
terminal, TB3-5 (GND).
4-A FB ReplaceableFuse
LED Communications
Indicators
Service
Switch
Use the P3 Connector to
connect the X1 Sensor.
TCON289 12/00