Rothenberger RO Instructions For Use Manual
Rothenberger RO Instructions For Use Manual

Rothenberger RO Instructions For Use Manual

Thermal imaging camera

Advertisement

Quick Links

RO THERMAL IMAGING
CAMERA
EN Instructions for use
rothenberger.com
Part No. 1000003350
MAN00150 REV 1.00321
1
ENGLISH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RO and is the answer not in the manual?

Questions and answers

Summary of Contents for Rothenberger RO

  • Page 1 RO THERMAL IMAGING CAMERA EN Instructions for use rothenberger.com Part No. 1000003350 MAN00150 REV 1.00321 ENGLISH...
  • Page 2: Table Of Contents

    Contents Page Introduction ............4 General saftey............4 RO thermal imaging camera overview ....5 Maintenance ............5 Cleaning ................5 Lens maintenance ............5 Batteries ..............6 How to charge batteries ..........6 Optimal battery performance ........6 Battery disposal ............6 Specifications ............7 Layout ..............8 Display ..............9 Colour code ..............9 Central point temperature cursor ........9...
  • Page 3 Contents Page 11.7 Emissivity sub menu - description .......14 11.8 Emissivity setting ............14 11.9 Application of emissivity measurement .....15 11.10 Emissivity vaule of common materials .......15 Settings ...............16 12.1 Auto shutdown setting ..........16 12.2 Intensity setting............16 12.3 Language setting ............17 12.4 Unit setting ..............17 12.5 Time format setting .............17 12.6 Time &...
  • Page 4: Introduction

    Introduction Thank you for purchasing our instrument. Use according to these instructions and maintain properly for optimal performance. IMPORTANT: Please read these instructions carefully. Note the safe opera- tional requirements, warnings & cautions. Use the product correctly and with care for the purpose for which it is intended. Failure to do so may cause damage and/or personal injury and will invalidate the warran- ty.
  • Page 5: Thermal Imaging Camera Overview

    The RO Thermal imaging camera uses a data storage system allowing the user to store images on the device. These can be extracted through USB to generate reports.
  • Page 6: Batteries

    commercial lens cleaner & a lint-free cloth or paper towel. • Wipe the lens surface by making circular motion. Then discard the cloth. • If it is necessary to repeat above step, please use new cloth to dip with the cleaning solution to wipe.
  • Page 7: Specifications

    Specifications Model RO Thermal imaging camera Display screen 2.8-inch full-view TFT display Temperature -20℃ to 300℃ (-4°F to 572°F) measurement range Measurement accuracy ±2℃/±2% (whichever is greater) Infrared image resolution 220×160 Visible image resolution 35200 pixel LCD resolution 320×240 Field angle 35°×26°...
  • Page 8: Layout

    Work temperature 0℃to 45℃ Storage temperature -20℃ to 60℃ Relative humidity < 85%RH This product has been tested for compliance with the following EMC This product has been tested for compliance with the following EMC Directive 2014/30/EU. Directive 2014/30/EU. Layout Colour display screen On/Off switch &...
  • Page 9: Display

    Display Current emissivity Battery Central point power temperature Colour code Highest temperature Central point cursor temperature cursor Lowest temperature cursor Time Maximum value & minimum value of field temperature Colour code Marks the colour corresponding to the relative temperature from low to high. (See colour palette menu for more details).
  • Page 10: Keypad Buttons

    Keypad buttons Selection key/Enter key Menu key & On/off key Navigation keys: Up, down, left & right Operation 10.1 Power on/off Press & hold the key for 3 seconds to turn the Thermal Imaging Camera on or off. 10.2 LCD screen display After turning on, the screen shows the thermal imaging status.
  • Page 11: Switching Between Image Types

    10.4 Switching between image types Press the “ ” or “ ” key to switch the degree of fusion between infrared thermal images & visible images (the degree of fusion is 0%, 25%, 50%, 75% & 100%). 10.5 Image capture Press the image capture trigger.
  • Page 12: Image Overlapping Application

    11.2 Image overlapping application Press the “MENU/ ” key to enter the main menu, & select “ ” image registration. Press the “SELECT/ENTER” key to enter into image overlap adjustment mode. Press the navigation keys (up, down, left & right to perform the visible image shift operation.
  • Page 13: Colour Palatte Sub Menu - Description

    the “ ” key. To delete the image press the “MENU/ ” key when yes is selected. 11.5 Colour palatte sub menu - description The palette can be used to change the pseudo-colour display of the infrared image on the display. Some tune swatches are better suited for specific applications &...
  • Page 14: Emissivity Sub Menu - Description

    Select “ ” (colour palette) option & press the “ ” key to enter the colour palette list. Press the “ ” & “ ” keys to navigate once in the colour pallete menu. Then press the “SELECT/ENTER” key to select the colour palette you desire.
  • Page 15: Application Of Emissivity Measurement

    11.9 Application of emissivity mesurement Emissivity Matt (e=0.95) Semi-matt (e=0.85) Semi-glossy (e=0.60) Glossy (e=0.30) Custom 0.01 As shown in the figure, press “MENU/ ” key to enter the main menu & select “ ”(emissivity) option & press “ ” key to enter the emissivity list. Press the “MENU/ ”...
  • Page 16: Settings

    Snow 0.83 Plastic 0.85~0.95 Glass 0.90~0.95 Timber 0.90 Ceramics 0.90~0.94 Paper 0.70~0.94 0.94 Chromium 0.81 Marble hemitrioxide Gypsum 0.80~0.90 Copper oxide 0.78 Mortar 0.89~0.91 Ferric oxide 0.78~0.82 Brick 0.93~0.96 Textile 0.90 Settings Press the “MENU/ ” key to select the “ ”(setting) option in the main menu.
  • Page 17: Language Setting

    auto power shutdown setting. Can be set how long you want it to be before the Thermal Imaging Camera automatically shuts down. 12.3 Language setting After selecting “ ” (Language, press the “ ” key to edit the language setting. Available in 2 languages: English & French. 12.4 Unit setting After selecting “...
  • Page 18: Enable/Disable Hotspot Cursor

    ” & “ ” key to change the value. After completing the change, press the “ SELECT/ENTER” key to enter. After setting, press the “ ” key to exit. 12.7 Enable/disable hotspot cursor In the cold hotspot menu “ ” you can toggle the hotspot on or off. Spot Press the “...
  • Page 19: Eu Declaraton Of Conformity

    EU declaraton of conformity This declaration of conformity is issued under the sole responsibility of the manufacturer:- Kane International Ltd. Kane House, 11 Bessemer Road, Welwyn Garden City, Hertfordshire. AL7 1GF, UK. Tel: +44 1707 375550 Web: www.kane.co.uk The KANE T-CAM is in conformity with the relevant Union harmonization legislation below: DIRECTIVE TITLE...
  • Page 20 Register your RO TCAM Register your RO TCAM to create your KAM dashboard: Simple online booking on www.kane.co.uk ★ Automatic reminder when due for recertification ★ FREE POSTAGE returning your Rothenberger analyser ★ SAME DAY annual FGA recertification OR YOUR MONEY BACK* ★...
  • Page 21 ROTHENBERGER Werkzeuge GmbH Industriestraße 7 D-65779 Kelkheim / Germany Telefon +49 6195 / 800 - 0 Telefax +49 6195 / 800 - 3500 info@rothenberger.com ROTHENBERGER (UK) LIMITED 2 Kingsthorne Park Henson Way Kettering Northants NN16 8PX Tel: +44 (0) 1536 310300 Fax: +44 (0) 1536 310600 E: info@rothenberger.co.uk...

Table of Contents