  • Page 1 SDM-16O Expansion Module – 16 digital outputs Version 1.2 User Manual Manufactured for...
  • Page 2 SDM-16O User Manual Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have been prepared with utmost care by our professionals and serve as a description of the product without incurring any liability for the purposes of commercial law.
  • Page 3: Safety Rules

    2. Module Features 2.1. Purpose and description of the module The SDM-16O module is an innovative device that provides a simple and cost- effective extension of the number of outputs in popular PLCs. The module has 16 digital outputs. All inputs and outputs are isolated from the logic of using optocouplers.
  • Page 4: Technical Specifications

    SDM-16O User Manual 2.2. Technical Specifications Voltage 10-30 VDC; 10-28VAC DC: 100 mA @ 24VDC Power Supply Maximum Current AC: 125 mA @ 24VAC Maximum power consumption DC: 2.4W; AC: 3VA No of outputs Max Voltage 30VDC Digital Outputs Max current...
  • Page 5: Dimensions Of The Product

    SDM-16O User Manual 2.3. Dimensions of the product Look and dimensions of the module are shown below. The module is mounted directly to the rail in the DIN industry standard. Power connectors, communication and IOs are at the bottom and top of the module. USB connector configuration and indicators located on the front of the module.
  • Page 6: Communication Configuration

    SDM-16O User Manual 3. Communication configuration 3.1. Grounding and shielding In most cases, IO modules will be installed in an enclosure along with other devices which generate electromagnetic radiation. Examples of these devices are relays and contactors, transformers, motor controllers etc. This electromagnetic radiation can induce electrical noise into both power and signal lines, as well as direct radiation into the module causing negative effects on the system.
  • Page 7: Communication Settings

    SDM-16O User Manual 3.4. Types of Modbus Registers There are 4 types of variables available in the module. Modbus Type Beginning adress Variable Access Command 00001 Digital Outputs 1, 5, 15 Read & Write 10001 Digital Inputs Read Registered 30001...
  • Page 8: Configuration Registers

    SDM-16O User Manual 3.5.3. Configuration registers Modbus Name Values 0 – 2400 1 – 4800 2 – 9600 3 – 19200 40003 0x02 Baud rate 4 – 38400 5 – 57600 6 – 115200 other – value * 10 0 – none 1 –...
  • Page 9 SDM-16O User Manual 4. Switches Switch Function Description Module address +1 Module address +2 Module address +4 Module address +8 Setting module address from 0 to 127 Module address +16 Module address +32 Module address +64 Restoring default settings Restoring (see 3.5.1 - Default settings i 3.5.2 - Restore the...
  • Page 10 SDM-16O User Manual 5. Front panel removing To remove the panel and gain access to the switch, you must pry open the panel using a thin tool (eg a small screwdriver) as in the picture below. Expansion Module – 16 digital outputs User Manual Version 1.2...
  • Page 11 SDM-16O User Manual 6. Indicators Outputs 1 – 8 state Communication mini USB configuration connector Power supply Outputs 9 – 16 state Indicators Description Power supply LED indicates that the module is correctly powered. Communication The LED lights up when the unit received the correct packet and sends the answer.
  • Page 12 SDM-16O User Manual 7. Module Connection – PNP outputs Expansion Module – 16 digital outputs User Manual Version 1.2 12 z 17...
  • Page 13 SDM-16O User Manual 8. Module Connection – NPN outputs Expansion Module – 16 digital outputs User Manual Version 1.2 13 z 17...
  • Page 14 SDM-16O User Manual 9. Modules Registers 9.1. Registered access Modbus Dec Register Name Access Description 30001 0x00 Version/Type Read Version and Type of the device 30002 0x01 Switches Read Switches state 40003 0x02 Baud rate Read & Write RS485 baud rate 40004 0x03 Stop Bits &...
  • Page 15: Bit Access

    SDM-16O User Manual 9.2. Bit access Modbus Register name Access Description Address Address Address 0x0C0 Default state of output 1 Read & Write Default state of output 1 0x0C1 Default state of output 2 Read & Write Default state of output 2 0x0C2 Default state of output 3 Read &...
  • Page 16: Configuration Software

    SDM-16O User Manual 10. Configuration software Modbus Configurator is software that is designed to set the module registers responsible for communication over Modbus network as well as to read and write the current value of other registers of the module. This program can be a convenient way to test the system as well as to observe real-time changes in the registers.
  • Page 17 SDM-16O User Manual Spis treści 1. Safety rules............................3 2. Module Features..........................3 2.1. Purpose and description of the module..................3 2.2. Technical Specifications......................4 2.3. Dimensions of the product.......................5 3. Communication configuration......................6 3.1. Grounding and shielding......................6 3.2. Network Termination.......................6 3.3. Setting Module Address in RS485 Modbus Network..............6 3.4.