Heat Transfer Sussman SVW Series Installation, Operation & Maintenance Manual

Heat Transfer Sussman SVW Series Installation, Operation & Maintenance Manual

Hot water boiler

Advertisement

Quick Links

Installation, Operation, Maintenance Manual & Spare Parts List
IMPORTANT NOTE:
As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient
installation and operation of electric boilers. These are two types of potential hazards that may occur during this installation and operation:
WA R N I N G
states a hazard which
maycause serious injury or death if precau-
tions are not followed.
C A U T I O N
signals a situation where
minor injury or product damage may occur if
you do not follow instructions.
439 Main Road, Towaco, New Jersey 07082
(718) 386-6666 • 1-800-221-1522
sussmanboilers.com • Email: seb@sussmancorp.com
Series SVW
Hot Water Boiler
Model No. _____________________
Boiler Serial No._________________
National Board No. _____________
Safety Valve Set Pressure ________
Power Circuit Voltage ___________
Control Circuit Voltage __________
Amps ____ Phase ____ HZ ______

TABLE OF CONTENTS

Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0
Operating Principles . . . . . . . . . . . . . . . 2.0
Specifications . . . . . . . . . . . . . . . . . . . . 3.0
Installation . . . . . . . . . . . . . . . . . . . . . . 4.0
Start-Up and Operation . . . . . . . . . . . . 5.0
Maintenance . . . . . . . . . . . . . . . . . . . . . 6.0
Drawings & Literature . . . . . . . . . . . . . 8.0
Trouble Shooting . . . . . . . . . . . . . . . . . 9.0
Warranty . . . . . . . . . . . . . . . . . . . . . . . 10.0
IMPORTANT NOTE:
This highlights information that is especially
relevant to a problem-free installation.
PSIG
PUR 100434 Rev 1.17

Advertisement

Table of Contents
loading

Summary of Contents for Heat Transfer Sussman SVW Series

  • Page 1: Table Of Contents

    Series SVW Hot Water Boiler Installation, Operation, Maintenance Manual & Spare Parts List Model No. _____________________ Boiler Serial No._________________ National Board No. _____________ Safety Valve Set Pressure ________ PSIG Power Circuit Voltage ___________ Control Circuit Voltage __________ Amps ____ Phase ____ HZ ______ TABLE OF CONTENTS Scope .
  • Page 2: Scope

    Installation, Operation & Maintenance Manual 1. Scope Sussman hot water boilers are designed and manufactured This manual details the installation, operation and mainte- to meet A.S.M.E. and code regulations. When properly nance instructions, and spare parts list for Sussman Series SVW operated and maintained, you can expect years of trouble Hot Water Boilers.
  • Page 3: Specifications

    Installation, Operation & Maintenance Manual 3. Specifications Front View Side View 3.1 Standard Boiler Accessories 18 20 7 The following shows the standard boiler accessories for SVW hot water boilers. Description Insulated ASME designed pressure vessel Vented control cabinet Pressure relief valve Inspection and cleanout holes 1, 9, 11, 12,13, 15,...
  • Page 4: Installation

    Installation, Operation & Maintenance Manual 4. Installation 4.1 General The boiler shall be installed by qualified personnel in accordance with the instructions contained in this manual. Furthermore, compliance with applicable National and local building and safety codes is necessary. 4.2 Pre-lnstallation 4.2.1 Inspect the boiler for possible damage due to shipping Do not return the unit unless advised, since field repair and handling.
  • Page 5: Start-Up And Operation

    Installation, Operation & Maintenance Manual 4.4 Plumbing (cont.) 4.4.5 Slowdown Piping 4.4.7 Expansion Tanks Most jurisdictions prohibit the blow-off from the boiler Some closed systems require an expansion tank. from being directly discharged into the sewer system. 4.4.8 Drain and Shut-off However, in all cases, you must check with local authorities All low points in the piping system should be equipped to ensure compliance with local regulations prior to the...
  • Page 6: Maintenance

    Installation, Operation & Maintenance Manual 5.1 Start-up (cont.) 5.1.10 Simulate a low water condition by depressing the “push-to- 5.1.13 The pointers on the pressure/temperature gauge (at the test” button. The boiler contactors should open and the red outlet of the boiler) should begin to rise until the tem- “low level light”...
  • Page 7: Gauge Glass Installation, Use & Care

    Installation, Operation & Maintenance Manual 7.0 Gauge Glass Installation, Use and Care IMPORTANT NOTE: Read all warnings and instructions Top Gauge before performing installation or maintenance. Safety glass- Fitting es and gloves should be worn at all times when working with or examining water gauge glass and connections.
  • Page 8: Drawings & Literature

    Installation, Operation & Maintenance Manual 7.0 Gauge Glass Installation, Use and Care (cont.) DO NOTs MAINTENANCE Examine the gauge glass regularly for any signs of • DO NOT use glass if it contains any scratches, chips, or clouding, scratching, erosion, or corrosion. The glass any other visible signs of damage.
  • Page 9: Trouble Shooting

    Installation, Operation & Maintenance Manual 9. Troubleshooting Guide 9.1 Failed Heaters • Multiple coincident failures are almost certainly the result in • Sussman boiler flange heaters are of the highest quality. a low water condition. When properly maintained, they should provide many years of service. •...