Analog Phasing Meters
©2022 Hubbell Incorporated | hpsliterature@hubbell.com | hubbellpowersystems.com

Advertisement

loading

Summary of Contents for CHANCE H1876

  • Page 1 Revision A 07/22 CHANCE Analog Phasing Meters ® Owner's Manual Model No. H1876, H18761, H18767, C4030457, C4030458 NOTICE: Before operating a CHANCE Phasing Meter, thoroughly ® read, understand and follow these instructions. Keep these instructions with product for future reference.
  • Page 2 A CAUTION refers to operating procedures, techniques, etc., that, if not followed carefully, could RESULT IN DAMAGE TO EQUIPMENT or LOSS OF SERVICE to customers. NOTICE A NOTICE refers to information that is considered important but not hazard related. ©2022 Hubbell Incorporated | Chance Phasing Meter Operating Instructions ®...
  • Page 3: Product Safety

    Should additional information and details be desired or if situations arise which are not covered adequately for the user’s purpose, the specifics should be referred to Hubbell Power Systems. ©2022 Hubbell Incorporated | Chance Phasing Meter Operating Instructions ®...
  • Page 4 Generic Components of the Phasing Meter Pigtail Hook Meter Shepherd's Hook Resistor Stick Test Point Resistor Stick Universal Couplings Cable Reel ©2022 Hubbell Incorporated | Chance Phasing Meter Operating Instructions ®...
  • Page 5 48 kV to 80 kV is to use two pairs of H18764 Extension Resistors, installed with two on the meter stick and two on the reel stick. NOTE: Extension Resistors are only for use on 16 kV maximum Phasing Meters. ©2022 Hubbell Incorporated | Chance Phasing Meter Operating Instructions ®...
  • Page 6 CAUTION In substations, bus and switchgear cubicles, or other crowded areas where electrical fields are of greater intensity, extra precaution is recommended to avoid disturbing influences affecting meter indications. ©2022 Hubbell Incorporated | Chance Phasing Meter Operating Instructions ®...
  • Page 7 Do not use any Probe or Bushing Adapters on the Phasing Meter when testing live-front URD equipment. Only use a small hex head machine screw (1/4-20 X 3/8"long). ©2022 Hubbell Incorporated | Chance Phasing Meter Operating Instructions ®...
  • Page 8 With no extensions, scale is direct reading. With one PAIR of H18764 extension multiply by 3. With two PAIRs of H18764 extension multiply by 5. T4030786 T4032311 1 & 16 kV 5 & 16 kV ©2022 Hubbell Incorporated | Chance Phasing Meter Operating Instructions ®...
  • Page 9 H18767 T4032261 40 kV 25 kV E4030499 E4030498 161 kV 120 kV NOTE: Multiply by 10 ©2022 Hubbell Incorporated | Chance Phasing Meter Operating Instructions ®...
  • Page 10 DC Hi-Pot Adapters C4031762 Up to 16 kV C4031763 Up to 35 kV Elbow Adapters T4030856 Up to 35 kV Bushing Adapters T4030428 Up to 15 kV T4030857 Up to 35 kV ©2022 Hubbell Incorporated | Chance Phasing Meter Operating Instructions ®...
  • Page 11: Maintenance

    Any remaining soap residue may allow high voltage tracking especially in the presence of high humidity and/or moisture. Do not use CHANCE Moisture Eater II wipes on any part of the tool ®...
  • Page 12: General Information

    3 lbs Meter less handles Carrying bag, weatherproof duck, for 161 kV Phasing C4030464 102" 3 lbs Meter less handles Phasing Voltmeter Tester for Transmission Phasing PSE4033473 1 lb Meter ©2022 Hubbell Incorporated | Chance Phasing Meter Operating Instructions ®...
  • Page 13 Bag for 48 kV Extension Resistors H18764 1 lb C4030838 Phasing Voltmeter Tester 1 lb C4031762 DC Hi-Pot Adapter up to 16 kV 1 lb C4031763 DC Hi-Pot Adapter up to 35 kV 1 lb ©2022 Hubbell Incorporated | Chance Phasing Meter Operating Instructions ®...
  • Page 14 NOTES ©2022 Hubbell Incorporated | Chance Phasing Meter Operating Instructions ®...
  • Page 15 NOTES ©2022 Hubbell Incorporated | Chance Phasing Meter Operating Instructions ®...
  • Page 16 Hubbell Power Systems, Inc. 210 N. Allen St Centralia, MO 65240 www.hubbellpowersystems.com Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications. PSP4034443 CENT_LTE_IOM_EN_00090 Revision A 7/22 ©2022 Hubbell Incorporated | hpsliterature@hubbell.com | hubbellpowersystems.com...

This manual is also suitable for:

H18761H18767C4030457C4030458