E2 Car Module Installation Sheet

Precautions

The module must be mounted in suitable protective box or car top terminal box. Observe
normal precautions for handling electronic devices, avoid static electricity, dampness and
extreme temperatures. Please read this instruction sheet fully before use.
Ethos 2 Car Module
The Car Module is designed to be mounted on the lift car. It is used to supply Ethos 2 with
door and other car COP signals. The unit has a built in 3-axis accelerometer for ride profile
monitoring, so must be mounted securely to avoid false triggering of the accelerometer.
I/O includes:- 8 volt free relay outputs, 12 x 24V d.c. feature inputs and 8 call I/Os. These
can be configured via the Ethos 2 MMI.
The module can additionally be used to interface to a load cell for load weighing. An RS232/
485 connection is supplied to drive car indicators or speech units.
Please consult main drawings for contract specific wiring and setup.

Specification

Supply Voltage
24V d.c.
Board Operating Current
300mA
Max Input Voltage (FI1-8)
24V d.c.
Max Output Current Call Outputs
300mA @ 24V d.c.
(per output, LED type indicators only)
Max Output Current Feature Outputs
500mA @ 24V d.c.
(FO1-8, per output)
Max Output Current BZ Output
1A @ 24V d.c.
Output Short Circuit Protection
Yes
Load Cell Inputs
0 – 10V d.c.
Serial Connections
USB (device), RS232, RS485
Dimensions (in DIN carrier)
210 x 90 x 60mm
Standards
EN81-20/50 (EN81-1/2)

DIP Settings

SW2
DIP Name
DIP 3 to set side
4
Test Mode
OFF = Front
3
Side
ON = Rear
2
Spare
1
Spare
DIP 4 for test mode (normally off)
SW3
DIP Name
DIPs 1 and 2 on for CAN termination
2
CAN Term
These should only be set on the last
1
CAN Term
node in the network.

Jumper / Reset Settings

SW1
Place Jumper in the lower position for N/O contact on FO1, upper for N/C
SW4
Place Jumper in the upper position for normal operation, lower for programming.
SW5
Reset Switch press to reset board.

USB Device Connection J2

The Car Module board has a USB micro device connector for programming and also to
output monitoring data from the built in 3 axis accelerometer, this is used for TVC factory
setup only.
We reserve the right to alter, without giving prior notice, technical data, dimensions and
weights described in this manual.
Thames Valley Controls Ltd. Manor Farm Industrial Estate, Flint, Flintshire CH6 5UY
(t): +44 (0) 1352 793222 (f): +44 (0) 1352 793255

Typical Wiring and Dimensions of Car Module

24V d.c. CPF
Car call feed
0V Car call return
Combined Car / Door Node Module
SW1 makes output 1
8 volt free relay outputs
N/C or N/O
(2A @ 24V d.c. / 110V a.c max)
The Green LED (D1) will flash every 2 seconds to signify power to node and
that the node is running.
The Red LED (D2) will light continuously for 4 seconds when the node is first
powered up. After this point the red LED signifies various fault codes. The LED
will do a quick flash every 4 seconds if the node has a fault.
-
Car push return
Output for
Module
Load cell
RS232 to
buzzer
power
interface
CARDIP
Front or Rear
Output 8
Output 8
1 - 4 return
N/O contacts
N/C contacts
0V d.c.
4 x inputs
24V d.c. max
210mm
Loop and Fault LED's
1 flash every 4 secs = Node not communicating with Ethos or EMU.
2 flashes every 4secs = Node is experiencing data bus faults.
3 flashes every 4 secs = Node has stopped transmitting due to bus faults.
4 flashes every 4 secs = Node has stopped transmitting or receiving from the
data bus
E2 Car Module
TVL 344 ISSUE 1
CAN Network
from Ethos and
to other
Network
Front / rear
modules
termination
+ test dips
ON
1 2
8 x inputs
24V d.c. max
5 - 12 return
0V d.c.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ethos Two and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TVC Ethos Two

  • Page 1 4 flashes every 4 secs = Node has stopped transmitting or receiving from the output monitoring data from the built in 3 axis accelerometer, this is used for TVC factory powered up. After this point the red LED signifies various fault codes. The LED data bus setup only.
  • Page 2 Ethos 2 serial system. Be aware that the lift panel will contain equipment that is supplied with potentially lethal voltages. Please make sure the panel is isolated before carrying out any installation work or modifications. The TVC Ethos 2 Serial System is a distributed field-bus network for interfacing calls and I/O to an Ethos 2 lift controller. The system is used in place of normal discrete wiring for calls and car related input and outputs.

This manual is also suitable for:

Ethos 2E2Tvl344

Table of Contents