Advertisement

Quick Links

Installation manual
FIMER FLEXA Stand-Basic

Advertisement

Table of Contents
loading

Summary of Contents for Fimer FLEXA Stand-Basic

  • Page 1 Installation manual FIMER FLEXA Stand-Basic...
  • Page 2 Operators are required to read this manual and adhere to the instructions contained therein. FIMER cannot be held liable for damages caused to persons and/or property, or to the equipment, if the conditions described below have not been met.
  • Page 3 READ THE MANUAL – Personnel involved in the use, maintenance and installation of the equipment must be qualified by FIMER (by means of a letter certifying their qualification) for the activities described and must reliably demonstrate their ability to correctly interpret what is described in the manual.
  • Page 4: Table Of Contents

    Table of contents General information 1.1 .......................Fields of use 1.2 ...................Symbols and definitions 1.3 ..............Product dimensions and features 1.4 .......................Support Safety and equipment 2.1 ....................Safety warnings 2.2 ......................Proper use 2.3....................Product handling Installation 3.1 .................. Preparing for installation 3.2....................Tools required 3.3 ....................
  • Page 5: General Information

    General information FIMER FLEXA Stand-Basic, thanks to its compact design and its flexibility, is a support suitable for the different versions of FIMER FLEXA AC Wallbox and for all positioning needs, both outdoor and indoor installations. It is available for single and double charging modes.
  • Page 6: Symbols And Definitions

    1.2 Symbols and definitions Symbol Description GENERAL WARNING THE ORIGINAL MANUAL OR OTHER ADDITIONAL DOCUMENTATION MUST BE CONSULTED PROHIBITION OR RESTRICTIONS THE OPERATIONS DESCRIBED MUST BE CARRIED OUT USING THE CLOTHING AND/OR PROTECTIVE EQUIPMENT PROVIDED BY THE EMPLOYER THE PRODUCTS SHOULD NOT BE DISPOSED OF WITH HOUSEHOLD WASTE, BUT COLLECTED IN A DIFFERENT MANNER AS, ALTHOUGH NOT COMPOSED OF MATERIALS HARMFUL TO HEALTH, THEY ARE MADE OF RECYCLABLE MATERIALS HAZARD-WARNING SIGNAL: PRESENCE OF ELECTRICAL VOLTAGE...
  • Page 7: Product Dimensions And Features

    Dimensions (l x h x w) 305 x 1500 x 305 mm Weight (Stand only) 11.92 kg 12.23 kg Material Steel S 235 JR EN 10025 Color RAL 7035 1.3.1 Views of FIMER FLEXA Stand-Basic (single) = 255 = 13.5 N°4 THROUGH HOLES...
  • Page 8 1.3.2 Views of FIMER FLEXA Stand-Basic (double) = 255 = 13.5 N°4 THROUGH HOLES...
  • Page 9: Support

    1.3.3 Views of FIMER FLEXA AC Wallbox's fixing plate 123,0000 57,0000 6,5000 30,0000 15,0000 114,0000 1,0000 12,5000 25,0000 1.4 Support For any reports or requests for further support, FIMER is available through the dedicated section of the website www.fimer.com or by writing to service.emobility@fimer.com.
  • Page 10: Safety And Equipment

    This document has been carefully checked by FIMER, but deviations cannot be completely ruled out. If errors are detected, the reader is kindly asked to notify FIMER. Except for explicit contractual commitments, in no case FIMER can be held responsible for any loss or damage resulting from the use of this manual or from the installation of the equipment.
  • Page 11: Installation

    3.3 Package contents • N.1 FIMER FLEXA Stand-Basic (single or double charging mode) • N.1 or 2 fixing plate(s), depending on the model, for FIMER FLEXA AC Wallbox • N.1 ground anchoring kit and N.1 fixing plate anchoring kit • Installation manual 3.4 Space and positioning...
  • Page 12: Unpacking

    ATTENTION – For versions of FIMER FLEXA AC Wallbox with mobile cellular or Wi-Fi connection, ensure that the selected area has cellular reception or Wi-Fi coverage. Before installation, ensure that the environmental conditions (such as temperature, altitude and humidity) comply with FIMER FLEXA AC Wallbox specifications.
  • Page 13: Installation

    (4) present holes. 3. Remove FIMER FLEXA Stand-Basic and drill the holes in the ground at the previously drawn marks. The hole should be drilled with proper drill and bit, keeping in mind that the plugs in the kit of installation are M8 plugs.
  • Page 14 5. FLEXA AC Wallbox assembly 1. Fix FIMER FLEXA Stand-Basic’s fixing plate to the main body of the Stand itself, using the four (4) screws provided with the anchoring kit. In this installation, the fixing plate supplied with the FIMER FLEXA AC Wallbox will not be used.
  • Page 15 6. Maintenance The product does not need planned maintenance, with the only exception for public installation points where a periodic inspection is suggested. In this installation sites damages such as inci- sions, scratches and any other kind of injuries may compromise the product’s service life.
  • Page 16 With regard to purchase orders, the agreed your local FIMER or utilization of its contents – in whole or in parts particulars shall prevail. FIMER does not accept representative or visit: – is forbidden without prior written consent of any responsibility whatsoever for potential errors FIMER.

Table of Contents