  • Page 1 ® GRU-V Air Purifier Product Manual...
  • Page 2 JenActUV Air Purifier – Product Manual ® GRU-V Last revision 15 June 2020 © JenAct Limited JenAct Limited 9/10 Ardglen Industrial Estate, Whitchurch, Tel: +44 1256 892194 Hampshire, RG28 7BB, United Kingdom Fax: +44 1256 896486 www.jenact.co.uk info@jenact.co.uk...
  • Page 3: Installation

    ® GRU-V Air Purifier Product Manual Description ® The GRU-V Air Purifier is an air treatment device which uses 254nm ultraviolet light to disable microorganisms. Thanks to its rigid construction and stainless-steel materials, the ® GRU-V is ideal for use in industry and small businesses. Package contents: ®...
  • Page 4: Service And Maintenance

    ® GRU-V Air Purifier Product Manual Service and Maintenance WARNING - HARMFUL ULTRAVIOLET LIGHT! ® THE GRU-V SHOULD NEVER BE OPERATED OR TESTED WITHOUT COVER FITTED. ® In applications where the GRU-V is used continuously, the UV lamps should be replaced ®...
  • Page 5 ® GRU-V Air Purifier Product Manual Replacing UV Lamps ® 1. Disconnect the GRU-V from mains. 2. Unscrew all eight M5 screws which hold the cover and slide the cover off the base. The base with components is shown in the picture on the previous page. 3.
  • Page 6: Technical Specifications

    ® GRU-V Air Purifier Product Manual Technical Specifications Operation Air flow rate: 82 m /h (119m /h nominal) UVC dose: 13mJ/cm (calculated average dose after 8,000 hours) Disinfection rates*: 99.99% kill rate of Coronavirus, Influenza A, MRSA, E-Coli (single pass, 4 log kill or higher) 99% kill rate of Anthrax (single pass, 2 log kill) 39% kill rate of Clostridium difficile (single pass) 92% kill rate of Clostridium difficile (five passes recirculation)
  • Page 7: Health And Safety

    ® GRU-V Air Purifier Product Manual Health and Safety UV LAMPS PRODUCE HARMFUL ULTRAVIOLET LIGHT WHICH MAY RESULT IN THE DAMAGE OF EYES AND SKIN. ® The leakage of ultraviolet light from the GRU-V has been measured at the air inlet/exhaust and was found to be minimal.
  • Page 8 ® GRU-V Air Purifier Product Manual Compliances EMC 2004/108/EC LVD 2014/35/EU RoHs 2002/95/EC Manufactured in the UK by Jenton International Limited 9/10 Ardglen Industrial Estate Ardglen Road Whitchurch, HAMPSHIRE RG28 7BB UNITED KINGDOM Tel:+44 (0)1256 892194 Fax:+44 (0)1256 896486...