Page 2
− Fill canister, use BOOST modus to speed up filling − If ECU stops filling, connect CDS adapter to device canister − Place A-adapter between nozzle and canister − De-aerate system − System is ready for use now! − www.flaco.de...
Page 3
Configuration / diagnosis MENU AND SUB-MENU Switch on the FLACOblue60 Press button “2” (RESET) until the password entry window appears Enter the password Press button “2” (Reset) to jump to the next option Press button “+” (3, BOOST) or “-“ (4, Func.) to change configuration www.flaco.de...
Page 4
“234432” menu Language English Unit Voltage actual battery voltage Ring sensor “o”= open, “x”= close Quad sensor “o”= open, “x”= close Pulse input “o”= open, “x”= close Check ring sensor and trigger Press A-Adapter into the nozzle, pull trigger www.flaco.de...
Page 5
Customer configuration and diagnosis password “234432” menu Language English Unit Voltage actual battery voltage Ring sensor “o”= open, “x”= close Quad sensor “o”= open, “x”= close Pulse input “o”= open, “x”= close Check Quad sensor Shorting two adjoining points www.flaco.de...