All manuals and user guides at all-guides.com Contents Introduction ....................4 Symbols used ............4 1.1.1 Symbols used in the manual ........4 1.1.2 Symbols used on the equipment ......4 Abbreviations ............5 General ..............5 1.3.1 Manufacturer's liability ..........5 1.3.2 Installer's liability .............6 1.3.3 User's liability ............6 Homologations ............6 1.4.1...
Page 3
All manuals and user guides at all-guides.com Contents Installation shutdown .........22 Turning on the antifreeze function ....22 Troubleshooting ..................23 Anti-hunting ............23 Messages .............23 Faults (Code type Lxx or Dxx) ......25 Technical specifications ................28 Technical specifications ........28 6.1.1 Electricity supply ...........28 6.1.2 Heat pump .............28 6.1.3...
Page 4
All manuals and user guides at all-guides.com 06/09/2012 - 300027618-001-01...
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 1. Introduction Introduction Symbols used 1.1.1. Symbols used in the manual In these instructions, various danger levels are employed to draw the user's attention to particular information. In so doing, we wish to safeguard the user's safety, obviate hazards and guarantee correct operation of the appliance.
All manuals and user guides at all-guides.com 1. Introduction AWHP MIT-IN iSystem Abbreviations 4 DHW: Domestic hot water 4 PPS: Polypropylene hardly inflammable 4 PCU: Primary Control Unit - PCB contoller for heat pump operation 4 PSU: Parameter Storage Unit - Parameter storage for PCBs PCU and SU 4 SCU: Secondary Control Unit - DIEMATIC iSystem control panel 4 SU: Safety Unit - Safety PCB...
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 1. Introduction 1.3.2. Installer's liability The installer is responsible for the installation and inital start up of the appliance. The installer must respect the following instructions: 4 Read and follow the instructions given in the manuals provided with the appliance.
All manuals and user guides at all-guides.com 2. Safety instructions and recommendations AWHP MIT-IN iSystem Safety instructions and recommendations Safety instructions DANGER If smoke is released or in case of refrigerant leak: Switch the appliance off. Open the windows. Evacuate the premises. Contact a qualified professional.
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 3. Description Description General description The AWHP MIT-IN iSystem heat pump is composed of two elements: 4 The outside unit handles energy production in hot or cold mode. 4 The inside module handles thermal exchange between the R410A fluid and the hydraulic circuit.
All manuals and user guides at all-guides.com 3. Description AWHP MIT-IN iSystem Temperature setting key (heating, DHW, swimming pool) Operating mode selection key DHW override key Key to access the parameters reserved for the installer Keys on which the function varies as and when selections are made ¼...
Page 11
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 3. Description The tank is not loaded - Presence of the solar control system n Operating modes Summer mode: Cooling is possible. Domestic hot water continues to be produced. WINTER mode: Heating and domestic hot water working. Forced cooling mode.
Page 12
All manuals and user guides at all-guides.com 3. Description AWHP MIT-IN iSystem n Domestic Hot Water override A bar is displayed when a DHW override is activated: Flashing bar: Temporary override Steady bar: Permanent override < AUTO n Electrical back-up The symbol 1 or 2 lights up, depending on whether stage 1 or 2 on the electrical back-up is commanded.
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 3. Description n Other information The symbol is displayed when domestic hot water production is running. Valve indicator: The symbol is displayed when a 3-way valve is connected. x : 3-way valve opens <...
Page 14
All manuals and user guides at all-guides.com 3. Description AWHP MIT-IN iSystem 7. To go back to the main display, press key j 2 times. It is possible to use the ( and ' keys instead of the rotary LUNDI 11:45 button.
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 4. Operating the appliance Operating the appliance Putting the appliance into operation 1. Switch on the power by throwing the on/off switch on the inside module. C002366-B 2. The first time the boiler is powered up, the LANGUAGE menu is displayed.
Page 16
All manuals and user guides at all-guides.com 4. Operating the appliance AWHP MIT-IN iSystem User level - Menu #MEASURES Parameter Description Unit Outside temperature °C OUTSIDE TEMP. Room temperature of circuit A °C ROOMTEMP. A Room temperature of circuit B °C ROOMTEMP.
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 4. Operating the appliance Changing the settings 4.3.1. Setting the set point temperatures To set the various heating, DHW and swimming pool temperatures, proceed as follows: 1. Press the C key. 2.
All manuals and user guides at all-guides.com 4. Operating the appliance AWHP MIT-IN iSystem 4.3.2. Selecting the operating mode To select an operating mode, proceed as follows: 1. Press the MODE key. 2. To select the desired parameter, turn the rotary button. 3.
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 4. Operating the appliance 4.3.3. Forcing domestic hot water production To force domestic hot water production, proceed as follows: 1. Press the r key. 2. To select the desired parameter, turn the rotary button. 3.
All manuals and user guides at all-guides.com 4. Operating the appliance AWHP MIT-IN iSystem 4.3.5. Setting the time and date 1. To access user level: Press the > key. 2. Select the menu #TIME .DAY. SUNDAY 11:45 Turn the rotary button to scroll through the menus or modify a value.
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 4. Operating the appliance User level - Menu #CHOICE TIME PROG. Parameter Adjustment range Description CURRENT PROG.A P1 / P2 / P3 / P4 Comfort programme activated (Circuit A) CURRENT PROG.B P1 / P2 / P3 / P4 Comfort programme activated (Circuit B) CURRENT PROG.C P1 / P2 / P3 / P4...
Page 22
All manuals and user guides at all-guides.com 4. Operating the appliance AWHP MIT-IN iSystem 6. b : Day selection Press key b / v until the symbol b is displayed. PROG P2 C Turn the rotary button to the right to select the day(s) desired. We Th "Select the days to v : Cancelling the day selection...
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 4. Operating the appliance User level - Menu #TIME PROGRAM Comfort periods / Filling enabled: P2 _______________ P3 _______________ P4 _______________ _______________ Monday TIME PROG.DHW Tuesday Wednesday Thursday Friday Saturday Sunday Monday TIME PROG.AUX...
All manuals and user guides at all-guides.com 5. Troubleshooting AWHP MIT-IN iSystem Troubleshooting Anti-hunting When the heat pump is in "anti-short cycle" operating mode, the symbol "?" flashes. This is a normal operating mode. When the restart temperature is reached, operation will be guaranteed. 1.
Page 25
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 5. Troubleshooting Code Messages Description Checking / solution The BL inlet on the PCU PCB The contact connected to the BL inlet is open. BL.BL INPUT OPEN terminal block is open. Antifreeze Contact the professional who takes care of protection.
All manuals and user guides at all-guides.com 5. Troubleshooting AWHP MIT-IN iSystem Faults (Code type Lxx or Dxx) 1. Make a note of the code displayed. The code is important for the correct and rapid diagnosis of the type of failure and for any technical assistance that may be SUNDAY 11:45 needed.
Page 27
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 5. Troubleshooting Code Faults Cause Description Checking / solution of the fault A room temperature sensor fault Bad connection ROOM S.A FAIL. B room temperature sensor fault Sensor fault ROOM S.B FAIL. C room temperature sensor fault ROOM S.C FAIL.
Page 28
All manuals and user guides at all-guides.com 5. Troubleshooting AWHP MIT-IN iSystem Code Faults Cause Description Checking / solution of the fault TA-S DISCONNEC SCU The Titan Active System® is on an open circuit Check that the connection cable between the SCU PCB and the anode is not severed Check that the anode is not broken Remarks: Domestic hot water production has stopped but can nonetheless be restarted using key...
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 6. Technical specifications Technical specifications Technical specifications 6.1.1. Electricity supply 230 V AC (+/- 10%) - 50 Hz 6.1.2. Heat pump Conditions of use: 4 Limit operating temperatures in Hot mode: - Water: +18 °C / +55 °C - Outside air: -15 °C / +35 °C (AWHP 6 MR, 8 MR)
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 7. Energy savings Energy savings Energy savings This chapter contains: 4 Energy-saving advice 4 Advice on setting the room thermostat correctly 7.1.1. Energy-saving advice 4 Do not block ventilation outlets. 4 Install reflective panels behind the radiators to prevent heat losses.
Page 32
All manuals and user guides at all-guides.com 7. Energy savings AWHP MIT-IN iSystem The setting of the control panel and/or of the remote control has a considerable influence on energy consumption. A few tips: 4 In the room in which the room thermostat is installed, it's advised not to use thermostatic valve radiators.
All manuals and user guides at all-guides.com AWHP MIT-IN iSystem 8. Warranty Warranty General You have just purchased one of our appliances and we thank you for the trust you have placed in our products. Please note that your appliance will provide good service for a longer period of time if it is regularly checked and maintained.
Page 34
All manuals and user guides at all-guides.com...
Page 35
All manuals and user guides at all-guides.com...
Page 36
Зубарев переулок, д. 15/1 Бизнес-центр «Чайка Плаза», офис 309 +7 (495) 221-31-51 DUEDI S.r.l. DE DIETRICH THERMIQUE Iberia S.L.U. www.duediclima.it www.dedietrich-calefaccion.es Distributore Ufficiale Esclusivo Av. Princep d’Astúries 43-45 De Dietrich-Thermique Italia 08012 BARCELONA Via Passatore, 12 - 12010 +34 932 920 520...
Need help?
Do you have a question about the HPI AWHP MIT-IN iSystem and is the answer not in the manual?
Questions and answers