Boiler sequence controller for modular boiler installations (108 pages)
Summary of Contents for Hamworthy TYNEHAM AHP60 14/18
Page 1
TYNEHAM HEAT PUMP CONTROL Hot water preheating with gaz complement INSTALLATION, COMMISSIONING AND SERVICING INSTRUCTIONS For all Tyneham heat pumps IMPORTANT NOTE THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING, OPERATING OR SERVICING EQUIPMENT...
Page 2
Site Assembly Hamworthy offer a service of site assembly for many of our products in instances where plant room area is restricted. Using our trained staff we offer a higher quality of build and assurance of a boiler built and tested by the manufacturer.
Tyneham Heat Pump Control - Installation, Use and Maintenance TABLE OF CONTENTS 1. WARNINGS AND COMPLIANCE ..................5 1.1. Unpacking and reservations ........................5 2. TECHNICAL SPECIFICATIONS ..................7 2.1. General ..............................7 2.2. Dimensions ............................... 7 2.3. Delivered unit ............................8 2.4.
Page 4
Tyneham Heat Pump Control - Installation, Use and Maintenance 9. HYDRAULIC DIAGRAMS AND CONFIGURATIONS ..........53 9.1. Symbols used in the diagrams ........................ 53 9.2. List of diagrams ............................54 10. ELECTRICAL VALIDATION ................... 77 12. SPARE PARTS LIST ....................... 78 11.
Tyneham Heat Pump Control - Installation, Use and Maintenance 1. WARNINGS AND COMPLIANCE 1.1. Unpacking and reservations With the carrier present, carefully check the general appearance of the packaging and of the control panel. If in doubt, do not use the appliance. In the event of disagreement, write to the carrier within 48 hours mentioning all reserves and send a copy of this letter to the After Sales Department.
Page 6
Tyneham Heat Pump Control - Installation, Use and Maintenance Electromagnetic compatibility (2004/108/CEE) • This appliance conforms with all requirements of the electromagnetic compatibility directive BS EN61000 - 6 - 1, BS EN61000 - 6 - 3. • This is a class A appliance. In a residential environment, this appliance may cause radio-electric interference.
Tyneham Heat Pump Control - Installation, Use and Maintenance 2. TECHNICAL SPECIFICATIONS 2.1. General The control panel is used to control the heat pump and the hydraulic station. In this way, it is possible to produce domestic hot water according to the Tyneham Heat Pump Control operating mode.
Tyneham Heat Pump Control - Installation, Use and Maintenance 2.4. Technical data Name of manufacturer HAMWORTHY Unique reference Tyneham Heat Pump Control Single-phase power supply 230 VAC 50Hz Rated current Casing protection index IP21 Pollution level Pollution level II Protection index...
Page 10
Tyneham Heat Pump Control - Installation, Use and Maintenance 1. OCI 351 2. Fuse slot 3. Low voltage power supply terminal block 4. Very low voltage power supply terminal block 5. RVS 21 main circuit board figure 4 - Inside view The RVS 21 regulator is protected with a 6.3 A fuse.
Tyneham Heat Pump Control - Installation, Use and Maintenance 3. INSTALLATION 3.1. Installation of the control panel 3.1.1. Installation recommendations The Tyneham Heat Pump Control control panel must be installed in a technical area. Avoid installing the regulating system under a water pipe. The equipment is intended to be wall mounted, using screws and anchors supplied (to be adapted to suit the wall structure), at operator height to facilitate the use of the control panel display.
Tyneham Heat Pump Control - Installation, Use and Maintenance 3.2. Installation of flow sensor in the tank or decoupling bottle The initial temperature sensor B10 must be located at the top of the water tank as close as possible to where the heating outlet connection.
Tyneham Heat Pump Control - Installation, Use and Maintenance 3.3. Electrical connection CAUTION: Do not pull the electrical cables and remove them from heat sources. Only carry out electrical connections, in particular connection to the main WARNING: supply, when all other fitting and installation work is completed. Installations carried out by the customer (cable runs, gas or fuel pipes, etc.) WARNING: must not be fitted to the Tyneham's jacket!
Page 14
Tyneham Heat Pump Control - Installation, Use and Maintenance 3.3.2. Tyneham Heat Pump Control wiring diagram figure 11 - Tyneham Heat Pump Control wiring diagram Page 14 / 86 00U07310080-A...
Page 15
Tyneham Heat Pump Control - Installation, Use and Maintenance 3.3.3. Tyneham Heat Pump Control main supply wiring Mains supply for the Tyneham Heat Pump Control: 230 V AC 50 Hz Maximum intensity: 6.3 A Type of cable: 3 G 1.5 mm² The installation is done directly by pressing with rigid cable or using a screw turner in case of use of flexible cable.
Page 16
Tyneham Heat Pump Control - Installation, Use and Maintenance 3.3.5. Connection to the main regulator figure 14 - Connection to the main regulator Connection of decoupling bottle flow sensor QAZ36. Connection of DHW pre-heating tank sensor. Connection of W3100 hydraulic station with H1-M = R1 (NO and Com respectively), and H3-M = R2 (NO and Com respectively) Connection of Rubis E1 Connection of the HP(s) alarm summary relay output and the hydraulic station:...
Page 17
Tyneham Heat Pump Control - Installation, Use and Maintenance 3.3.6. Changing the Fuse - Set the switches to "Off". - Switch off the electric power supply to the controller - Open the door using the key. - Remove the fuse cover. - Remove and replace the fuse.
Tyneham Heat Pump Control - Installation, Use and Maintenance 4. USER INTERFACE 4.1. Presentation of the interface The Tyneham Heat Pump Control controller user interface comprises: - An On/Off switch, - An Tyneham system fault summary indicator light (whether alone or cascaded), - A back-lit LCD display, - Two function buttons - A setting knob,...
Page 19
Tyneham Heat Pump Control - Installation, Use and Maintenance 4.2.1. Browsing between the different screens Standard DHW setpoint Info screen screen screen Auto return End user level parameter Special settings screen programmes Start-up 5 seconds Installer OEM with code 4.2.2. Tyneham HMI preset standard browser display The basic display of the Tyneham Heat Pump Control in DHW pre-heating mode includes the following information:...
Tyneham Heat Pump Control - Installation, Use and Maintenance 4.3. Fault display When a non-blocking fault occurs, a small bell appears in the upper left corner of the display. To display the fault, press the information key This type of fault does not cause operation to be blocked, requiring manual intervention..
Tyneham Heat Pump Control - Installation, Use and Maintenance 4.4. Tyneham HMI browsing U: user S: Specialist protected by password (195) * Only if fault in progress ** Only if USB drive detected with suitable files OH2: available only on Tyneham AHP60 50 or 70kW Edition: 10 / 2022 Page 21 / 86...
Page 22
Tyneham Heat Pump Control - Installation, Use and Maintenance 4.5. HP status From the basic display, you can scroll basic heat pump information (see list below). Access Setting Exit HP status DHW status Outdoor temperature DHW temperature Heat pump return temperature HP flow temperature Line start temperature Compressor hours of operation...
Tyneham Heat Pump Control - Installation, Use and Maintenance 4.6. Settings Depending on the functions commanded, there are different levels of access to the settings There are 3 access levels: U: End user M: Commissioning (reception, starting up), S: Specialist (technical level). 4.6.1.
Tyneham Heat Pump Control - Installation, Use and Maintenance 5. OPERATING CYCLES 5.1. Heat Pump start-up When there is a request for heat, the heat pump start-up cycle is as follows: Tyneham Heat Pump Control display Tyneham display Pump and compressor Standby state Standby state Pump running...
Tyneham Heat Pump Control - Installation, Use and Maintenance 6. DIAGNOSTIC HELP Description 1st diagnostic DHW temperature sensor B3 fault Check the pre-heating tank temperature sensor. Special sensor 1 fault. Check special sensor 1 declared on input Bx. Short circuit fault on the LPB bus, or no Check that the two bus wires are not LPB bus power.
Page 26
Tyneham Heat Pump Control - Installation, Use and Maintenance Maintenance Maintenance description code The heat pump operating hours meter has reached the limit set for preventive maintenance. The heat pump start-up counter has reached the limit set for preventive maintenance. Compressor start-up frequency...
Page 27
Tyneham Heat Pump Control - Installation, Use and Maintenance Other symptoms Description 1st diagnostic Look for the origin of the overload, No display on the LCD interface Tyneham Heat Pump Control fuse fault correct the fault, then replace the fuse. Incorrect accessory connection...
Tyneham Heat Pump Control - Installation, Use and Maintenance 7. LIST OF PARAMETERS Line See subsection..., Line See subsection..., Programming Programming page... page... Time setting 5933 Sensor input BX4 8.5.1.1, page 39 Hours / minutes 8.1.1, page 31 5950 H1 input function 8.5.1.1, page 39 5951 H1 contact action direction...
Page 29
Tyneham Heat Pump Control - Installation, Use and Maintenance Line See subsection..., Line See subsection..., Programming Programming page... page... 7840 H1 voltage signal 8.9.3, page 49 8131 Generator 16 status 8.11.1, page 52 7841 H1 contact status 8.9.3, page 49 8138 Cascade starting temperature 8.11.1, page 52...
Tyneham Heat Pump Control - Installation, Use and Maintenance 8. PARAMETERS 8.1. "User interface" parameters 8.1.1. Time setting Line Programming Possible values Hours / minutes 00:00 … 23:59 Day / month 01:01… 31.12 Year 1900 … 2099 Start of summer time 01:01…...
Page 31
Tyneham Heat Pump Control - Installation, Use and Maintenance Operation locking (26): If the operation locking function is enabled, the following control elements cannot be adjusted any longer: Heating circuit mode, hot water mode, temp. room temperature comfort setpoint (button), occupied button. Programming locking (27): If the programming locking function is enabled, the following control elements cannot be adjusted any longer:...
Page 32
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.1.3.1. Time programme (DHW circuits) Line no. Programming Possible values Preselection Mon-Sun | Mon-Fri | Sat-Sun | Mon…Sunday 1st period start time 00:00 … 24:00 1st period stop time 00:00 … 24:00 2nd period start time 00:00 …...
Page 33
Tyneham Heat Pump Control - Installation, Use and Maintenance Example of settings for a charge between 22:00 and 06:00 the next day If no setting is made for 8 minutes, the screen returns automatically to the basic display. Every time the user accesses the "DHW timer programme 4" menu, the first parameter displayed is 560 "Preset".
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.2. “DOMESTIC HOT WATER (DHW)” PARAMETERS The Tyneham Heat Pump Control recognises that it has to control a DHW circuit when a sensor is connected to its B3 input. The Tyneham Heat Pump Control can control a DHW actuator (Q3 DHW pump to be defined in QX3).
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.3. "Heat pump" parameters The Tyneham heat pump produces heat within a preset outdoor temperature range. Beyond this range, the Tyneham Heat Pump Control forces the Tyneham to switch off. Line Programming Possible values 2812...
Page 36
Tyneham Heat Pump Control - Installation, Use and Maintenance Param. 5036 DHW setpoint DHW setpoint activation Param. 1610 Param. 5020 DHW sensor B3 B10 line output sensor PAC setpoint Compressor Min. modulation modulation Param. 2926 DHW request Param. 5008 Time range (561-566) Charge regulation logic in time range: DHW charging is carried out gradually over a defined time range.
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.5. "Configuration" settings The heat pump controller must be properly configured to adapt to boiler room demands for Tyneham type DHW pre-heating applications only. It has four configurable 230V outputs (QX1, QX2, QX4, and QX5), one configurable dry contact output (QX3), three configurable sensor inputs (BX1, BX3 and BX4) and two 0...10 volt or on/off inputs (H1 and H3).
Page 38
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.5.1. Hydraulic configuration 8.5.1.1. Assigning the Tyneham model and the application* Line Programming 5700 Preselect This parameter is used to preset a number of values that ensure a match between the Tyneham Heat Pump Control heating or hot water application and the model of the Tyneham used in the installation.
Page 39
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.5.2. Configuring Tyneham Heat Pump Control inputs / outputs 8.5.2.1. Relay output QX* Line no. Programming Possible values 5890 5891 5892 5894 5895 Relay output QX1, 2, 3, 4, 5 None | Consumption circuit pump 1 Q15 | Consumption circuit pump 2 Q15 | Pool circuit pump Q19 | Heating circuit 3 pump Q20 | Alarm...
Page 40
Tyneham Heat Pump Control - Installation, Use and Maintenance Time programme 5 K13 The relay is controlled by the settings for timer programme 5. Compressor stage 1 K1 The relay is used to control the first stage of the compressor. This assignment can be used to notify the HP operation request to an external regulator (outside the defrosting cycle).
Page 41
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.5.2.3. Inputs H1 / H3* Line no. Programming Possible values none | switching of heating circuit + DHW operation | 5950 5960 Function input Hx switching of heating circuit modes | switching of heating circuit 1 mode | switching of heating circuit 2 mode | HC3 rate switching | error message...
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.5.2.4. Register sensor* If faulty sensors are detected after installation and to avoid integrating them with correct status (which may occur if automatic detection is used), there is a Commissioning function. This function learns to recognise the connected sensors and, if a fault occurs, generates an error message while inhibiting any installation diagram change.
Page 43
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.6.1. LPB address* Line Programming Possible values 6600 Appliance address 0 … 16 6601 Segment address 0 ... 14 The device address identifies every device on the bus, in a similar way to a postal address.
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.7. "Error" parameters As soon as an error occurs, an error message can be seen at the Info level via the Info button. The display shows the cause of the error. The heat pump controller records the last ten faults.
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.8. "Maintenance/Special operation" parameters 8.8.1. Maintenance function Line Programming 7070 Heat pump interval 7071 Time since heat pump maintenance 7072 Max starts compr 1/hrs run 7073 Cur starts compr 1/hrs run Heat pump interval Sets the interval (in months) between heat pump servicing.
Page 46
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.8.3. Commissioning* Line Programming Possible values 7202 Heat pump commissioning Off | Heating | Cooling 7207 Select heat pump power modulation 7214 Test funct. mode Commissioning The commissioning function allows the Tyneham heat pump to the heat pump operate in line with consumer requirements.
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.9. "Inputs/outputs test" parameters The inputs/outputs test is used to ensure that the connected components operate properly. The selected sensor values are updated with a maximum of 5 seconds. The display does not take CAUTION: into account any corrections to the measured values.
Page 48
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.9.2. Sensor input test Line Programming Possible values 7804 Sensor T° BX1 -28 … 350°C 7806 Sensor T° BX3 -28 … 350°C 7807 Sensor T° BX4 -28 … 350°C The input test is used to read the current measurement values from the device input terminals.
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.10. "Status" parameters The current operating state of the installation is viewed using the status displays. Line no. Programming 8003 DHW status Final user (info level) Commissioning, specialist Status No. Active manual intervention. Active manual intervention.
Page 50
Tyneham Heat Pump Control - Installation, Use and Maintenance Line no. Programming 8006 HP status Final user (info level) Commissioning, specialist Status No. Fault. Fault. Limit outdoor min. temp Limit outdoor max. temp Locked Limit compressor hot gas Limit max. stop temperature Limit min.
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.11. "Diagnostics" parameters 8.11.1. Cascade diagnostics Various setpoints and true values, relay switching states and generator states may be displayed for diagnostics purposes. Line no. Programming Possible values 8100, 8102, 8104, 8106, 8108, 8110, Generator priority 0 …...
Page 52
Tyneham Heat Pump Control - Installation, Use and Maintenance 8.11.3. Modbus slave diagnostics The information below is used to troubleshoot the Tyneham heat pump via the signals exchanged over the Tyneham Heat Pump Control / Tyneham communication network Line no. HMI text Related functions Possible values...
CAUTION: Hamworthy. When the system is commissioned, a balance check will be required by Hamworthy. If no check is performed, commissioning will be refused. 9.1. Symbols used in the diagrams Symbol...
Tyneham Heat Pump Control - Installation, Use and Maintenance 9.2. List of diagrams Heat Pump only with one Pre-Heating Tank ..........55 1 decoupling bottle or tank, 1 DHW pre-heating tank Heat Pump only with two Pre-Heating Tanks ........... 60 2 or 3 DHW preheating tanks 2 or 3 Heat Pumps Cascade with one Pre-Heating Tank ......
Page 55
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams HYF110 Heat Pump only with one Pre-Heating Tank HYF111 1 decoupling bottle or tank, 1 DHW pre-heating tank page 1 / 5 HYDRAULIC DIAGRAM figure 16 - Diagram HYF110 figure 17 - Diagram HYF111 REGULATION ACCESSORIES REQUIRED Quantity Appliance reference...
Page 56
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF110 - HYF111 page 2 / 5 DESCRIPTIONS The HP supports DHW production during a time period with a configurable duration. Care will be taken to ensure that draw-offs are virtually non-existent during this time period. The HP supports DHW production during a time period with a configurable duration.
Page 57
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF110 - HYF111 page 3 / 5 HYDRAULIC STATION Controller terminals QX3 / FX3 Controller terminals Controller terminals H1-M H3-M HYDRAULIC STATION PROGRAMMING " Start up the hydraulic station The hydraulic station arrives pre-programmed and requires no INFORMATION: specific adjustment.
Page 58
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF110 - HYF111 page 4 / 5 SPECIFIC START-UP PROCEDURE " Make the accessories' electrical connections. " Start up the HP on its own. " Perform the following settings in "Specialist" mode: Short press Press 3 seconds End user...
Page 59
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF110 - HYF111 page 5 / 5 Line No. Value 5°C Set the DHW over-value (preset) Flow setpoint over-value (5020) • Timer programme 4/DHW menu Preselection (560) Monday-Sunday Preselection 1st phase ON (561) 00: 00 h Adjust the timer programming 1st phase Off (562)
Page 60
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams Heat Pump only with two Pre-Heating Tanks HYF120 2 or 3 DHW preheating tanks page 1 / 5 HYDRAULIC DIAGRAM figure 18 - Diagram HYF120 REGULATION ACCESSORIES REQUIRED Quantity Appliance reference Order No.
Page 61
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF120 page 2 / 5 When 2 or more DHW preheating tanks are linked to the HP, it is necessary to add an isolation valve at the plate exchanger’s secondary inlet in order to prevent cold water from being bypassed to the hot water tank during the drawing-off phases.
Page 62
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF120 page 3 / 5 HYDRAULIC STATION Controller terminals 2WV tank QX3 / FX3 Controller terminals Controller terminals H1-M H3-M HYDRAULIC STATION PROGRAMMING " Start up the hydraulic station The hydraulic station arrives pre-programmed and requires no INFORMATION: specific adjustment.
Page 63
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF120 page 4 / 5 SPECIFIC START-UP PROCEDURE " Make the accessories' electrical connections. " Start up the HP on its own and the hydraulic station. " Perform the following settings in "Specialist" mode: Short press Press 3 seconds End user...
Page 64
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF120 page 5 / 5 Line No. Value 2nd phase ON (563) 22: 00 h Adjust the timer programming 2nd phase Off (564) 24: 00 h Adjust the timer programming •...
Page 65
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams 2 or 3 Heat Pumps Cascade with one Pre-Heating Tank HYF210 1 decoupling bottle or tank, 1 DHW pre-heating tank page 1 / 6 HYDRAULIC DIAGRAMS figure 19 - Diagram HYF210 REGULATION ACCESSORIES REQUIRED Quantity Appliance reference...
Page 66
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF210 page 2 / 6 FUNCTIONAL EXPLANATIONS The HP supports DHW production during a time period with a configurable duration. Care will be taken to ensure that draw-offs are virtually non-existent during this time period. The HP supports DHW production during a time period with a configurable duration.
Page 68
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF210 page 4 / 6 HYDRAULIC STATION Controller No.1 terminals QX3 / FX3 Controller No.1 terminals Controller No.1 terminals H1-M H3-M HYDRAULIC STATION PROGRAMMING " Start up the hydraulic station The hydraulic station arrives pre-programmed and requires no INFORMATION: specific adjustment.
Page 69
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF210 page 5 / 6 SPECIFIC START-UP PROCEDURE " Make the accessories' electrical connections. " Start up each HP. " Perform the following settings in "Specialist" mode: Short press Press 3 seconds End user Commissioning Specialist...
Page 70
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF210 page 6 / 6 Line No. Value 2nd phase ON (563) 22: 00 h Adjust the timer programming 2nd phase Off (564) 24: 00 h Adjust the timer programming •...
Page 71
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams 2 Heat Pumps Cascade with 2 or 3 Pre-Heating Tanks HYF220 1 decoupling tank, 2 or 3 DHW pre-heating tanks HYF23a page 1 / 6 HYDRAULIC DIAGRAMS figure 21 - Diagram HYF220 figure 20 - Diagram HYF23a REGULATION ACCESSORIES REQUIRED Quantity...
Page 72
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF220, HYF23a page 2 / 6 FUNCTIONAL EXPLANATIONS The HP supports DHW production during a time period with a configurable duration. Care will be taken to ensure that draw-offs are virtually non-existent during this time period. The HP supports DHW production during a time period with a configurable duration.
Page 74
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF220, HYF23a page 4 / 6 HYDRAULIC STATION Controller No.1 terminals 2WV tank QX3 / FX3 Controller No.1 terminals Controller No.1 terminals H1-M H3-M HYDRAULIC STATION PROGRAMMING " Start up the hydraulic station The hydraulic station arrives pre-programmed and requires no INFORMATION: specific adjustment.
Page 75
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF220, HYF23a page 5 / 6 SPECIFIC START-UP PROCEDURE " Make the accessories' electrical connections. " Start up each HP. " Perform the following settings in "Specialist" mode: Short press Press 3 seconds End user Commissioning...
Page 76
Tyneham Heat Pump Control - Installation, Use and Maintenance Diagrams: HYF220, HYF23a page 6 / 6 Line No. Value • Timer programme 4/DHW menu Preselection (560) Monday-Sunday Preselection 1st phase ON (561) 00: 00 h Adjust the timer programming 1st phase Off (562) 06: 00 h Adjust the timer programming 2nd phase ON (563)
Tyneham Heat Pump Control - Installation, Use and Maintenance 10. ELECTRICAL VALIDATION Tyneham Heat Pump Control: Line No. Value • Inputs/outputs test menu Check the sensor values B10 line output sensor Temp. sensor BX3 (7806) - - - °C Temp. sensor BX4 (7807) - - - °C DHW sensor B3 Check input H1/ H3...
- Install a pressure sensor on the outside safety input to the Tyneham controller (refer to the Tyneham instructions) 12. SPARE PARTS LIST REF. FOR MODELS ITEM DESIGNATION Hamworthy Empty Tyneham Heat Pump Control case AA79681 Tyneham Heat Pump Control lock with key AA79689 Tyneham Heat Pump Control door only AA79685...
Page 79
Tyneham Heat Pump Control - Installation, Use and Maintenance figure 22 - Tyneham Heat Pump Control set Edition: 10 / 2022 Page 79 / 86...
Tyneham Heat Pump Control - Installation, Use and Maintenance 13. ADDITIONAL ACCESSORIES Each additional accessory is delivered with its own instructions (fitting, electrical connections and use). 13.1. Temperature sensors 13.1.1. Sensors not included with the control panel (to be ordered separately as acces- sories) •...
Page 82
Tyneham Heat Pump Control - Installation, Use and Maintenance Page 82 / 86 00U07310080-A...
Page 83
Tyneham Heat Pump Control - Installation, Use and Maintenance Check list prior to commissioning Tyneham Please refer to the Tyneham manual for more details on the criteria for accepting readings Outdoor unit: Outdoor positioning (check that the recommendations are complied with): Outdoors Alcove ...
Page 84
Tyneham Heat Pump Control - Installation, Use and Maintenance Hydraulic station and DHW tanks: Communication connected between the station and the controller No.1 (3 pairs): Yes No A group or a safety valve is directly connected to each tank: ...
Page 85
Tyneham Heat Pump Control - Installation, Use and Maintenance Edition: 10 / 2022 Page 85 / 86...
Page 86
Wessex House, New Fields Business Park, Stinsford Road, Poole, Dorset, BH17 0NF Telephone: 01202 662500 Fax: 01202 662522 Email: aftersales@hamworthy-heating.com Website: www.hamworthy-heating.com Hamworthy reserves the right to make changes and improvements which may necessitate alteration to the specification without prior notice.
Need help?
Do you have a question about the TYNEHAM AHP60 14/18 and is the answer not in the manual?
Questions and answers