NC377 Paging Interface Adapter
Installation & Operating Instructions
Contents
Chapter 1-Introduction ..................................................... 1
About This Manual .........................................................1
Theory of Operation ........................................................2
What's in the Box ............................................................2
Features ...........................................................................2
Chapter 2-Installation ...................................................... 3
Mounting & Cable Routing .............................................3
Nurce Call Wire Connections ..........................................3
Power Up Sequence .........................................................3
Chapter 3-Programming Plan ..........................................
Chapter 4-Programming .................................................. 4
Default User Name & Password ......................................4
Global Settings Programming ..........................................4
Contact Input Programming .............................................6
Print Database Button .....................................................7
Finishing Up ....................................................................7
Chapter 5-Reporting ........................................................ 8
Log On .............................................................................8
Report Types ...................................................................8
Appendix ........................................................................... 10
Changing a PC's IP Subnet ............................................ 10
SD Card Use .................................................................. 10
Cables ............................................................................ 10
Troubleshooting ............................................................ 11
ComPPage License Agreement ...................................... 11
Illustrations
Figure 2-NC377 Cable Routing ......................................2
Figure 4-Port Name Drawing, Front ..............................2
Figure 10-Report Options Screen ..................................8
Figure 11-Report Examples ............................................9
Figure 12-SD Card Maintenance ................................. 10
Figure 13-8P8C Cable Terminations ............................ 11
ALPHA COMMUNICATIONS
Toll-Free Technical Line: 1-800-666-4800 • Phone: (631) 777-5500 • Fax: (631) 777-5599
Website: www.AlphaCommunications.com • Email: info@alphacommunications.com
3
The NC377 Paging Interface Adapter is used with TekTone
NC110, NC150 and NC200 hard-wired nurse call systems to
add radio pocket paging. The interface is connected between
the nurse call system and the radio pocket pager transmitter.
The NC377 Paging Interface Adapter detects calls, determines
priority, and then sends information to the NC369 Paging
Transmitter. Program call points so that calls are sent to the
appropriate pager. Information sent includes call type and room
number. The pager stamps the time and date.
This manual is designed to assist with installation of this
TekTone
with step-by-step instructions to facilitate hardware installation
and software configuration.
®
• 42 Central Drive • Farmingdale, NY 11735-1202

Figure 1-NC377/32 Paging Interface Adapter

Chapter 1-Introduction

About This Manual

®
product. Each component of the system is described
1. Important: Please take all precautions against high
voltage shock.
2. Use an ESD wrist strap when working with the SD or
Contact Input Cards.
3. Remove power from the unit before SD or input card
removal or replacement, and for wire installation.
IL871
Section E
Rev. 4 - 06/2011
®

Advertisement

Table of Contents
loading

Summary of Contents for Alpha Communications TekTone NC377

  • Page 1: Table Of Contents

    3. Remove power from the unit before SD or input card Figure 13—8P8C Cable Terminations ......11 removal or replacement, and for wire installation. ALPHA COMMUNICATIONS ® • 42 Central Drive • Farmingdale, NY 11735-1202 Toll-Free Technical Line: 1-800-666-4800 • Phone: (631) 777-5500 • Fax: (631) 777-5599...
  • Page 2: Theory Of Operation

    1. Important: Please use proper splicing techniques. What’s in the Box There will be many splices made to install this unit. • NC377-series Paging Interface Adapter (see Figure 1). • Mounting hardware. 2. Verify proper polarity of input wires (should be +). •...
  • Page 3: Chapter 2-Installation

    Chapter 2—Installation Chapter 3—Programming Plan This section outlines the overall programming plan. Refer to Mounting & Cable Routing Chapter 4—Programming for step-by-step programming Verify that power to the unit is disconnected before proceeding. instructions. (Note: The terms zone and input are used interchangeably in this manual and on the programming screens.) Please follow these steps.
  • Page 4: Chapter 4-Programming

    Chapter 4—Programming Global Settings Programming Default User Name & Password Referring to the Figure 7, while logged on to the interface, configure the following: The NC377 is shipped with the following default user name and password: Date and Time—(Master NC377 only.) The NC377 has an RTC User Name: comppage (real time clock).
  • Page 5: Figure 5-Nc377 Programming Welcome Screen

    Shift Schedule—(Master NC377 only.) This option enables 4. If Shift 3 does not complete the 24-hour period, the automatic shift change paging. unused time allocated to Shift 3, and any page during that time will be sent to Shift 3 pagers. 1.
  • Page 6: Contact Input Programming

    Programming Contact Inputs Contact Input Programming Start with Zone (input) # 1. Include room number and bed Click on the Contact Settings button at the bottom of the identifier in all four message types (marked *). Global Settings programming screen. The screen shown in Figure 8 will appear.
  • Page 7: Print Database Button

    Shift 1, Shift 2 and Shift 3 Pagers (Figure 9) Simplified Contact Input Programming Enter a Pager ID for each of the message types and Create one zone/input and click Save Zone. Then make a shifts being used. Each shift has three Pager IDs: copy of that zone/input using Save to Zone, and modify •...
  • Page 8: Chapter 5-Reporting

    Chapter 5—Reporting Report Types Reports can be created without entering a date, room number The NC377 can store multiple days of data logs on the 1GB SD or type of call. Because this type of report is very general and card located on the processor board.
  • Page 9: Figure 11-Report Examples

    Room Number, Date, Call Type & Elapsed Time—shows a list of calls of a single call type placed from a specific room on Figure 11—Report Examples one date or range of dates. This report also includes the time elapsed from call placement to call reset (Figure 11c). 1.
  • Page 10: Appendix

    Appendix SD Card Use Removing the SD Card from the NC377 Changing a PC’s IP Subnet 1. Remove power from the NC377. 1. You must be the administrator on the PC/laptop. 2. Remove the four screws holding the top cover on and set 2.
  • Page 11: Troubleshooting

    Software License Agreement Troubleshooting Read this License Agreement before using the software. If a master or master–slave configuration is not sending data This agreement is a legal contract between you, the end to the paging transmitter, check the following. user, and comPPage, Inc. governing your use of the Software.
  • Page 12: A Word About Esd (Electrostatic Discharge)

    A Word about ESD (Electrostatic Discharge) What The Installer Can Do In humid climates or in places where the relative humidity is What Is It? kept at 65% or greater, there will likely be few problems with Static electricity is a result of triboelectric charging of two ESD.