CM800/CM900
Emergency Call Signaling System
Installation & Operating Instructions
Contents
System Installation ............................................................. 1
Installation Procedure ......................................................1
Equipment Locations .......................................................1
Wire Checkout .................................................................2
Figure 1—Master Panel Housing Chart and
Wall Cut-Out Details ...............................................3
Figure 2—Ring and Back Box for SF117 series, SF118
series and SF154 Emergency Call Stations .............3
Figure 3—Ring and Back Box for IR019 & IR019B
Tone Speakers, and LI118B, LI123B, LI381,
LI382 & LI382LED Corridor Lights .........................3
Figure 4—PK2019A Tone Volume Shunt Settings .................3
Figure 5—Emergency Call Hook-Up Diagram
with SF117/2 series, SF118 series &
SF154 Emergency Switches, and
LI381 & LI118B Corridor Lights ..............................4
Figure 6—Emergency Call Hook-Up Diagram with
SF117/4 series Continuous Duty Door Release,
LI381 Corridor Light, LI123B Corridor Light
with Buzzer, and BE005 Corridor Bell ......................5
Figure 7—Emergency Call Hook-Up Diagram with
SF117/2 series Continuous Duty Door Release,
LI381 Corridor Light, Smoke Detector,
and BE007 Corridor Bell ..........................................6
Figure 8—Connection Diagram for Parallel
CM800 Panels .........................................................6
ALPHA COMMUNICATIONS
Toll-Free Technical Line: 1-800-666-4800 • Phone: (631) 777-5500 • Fax: (631) 777-5599
Website: www.AlphaCommunications.com • Email: info@alphacommunications.com
• Read the following instructions concerning system equip-
ment, and determine installation methods before proceed-
ing.
• Determine equipment locations.
• Install wiring.
• Install housings.
• Check wires.
• Connect equipment.
• Check connections.
• Apply power.
• Check system operation.
CM800, CM900 Annunciator: Locate CM800 and CM900
Annunciators within easy reach of operating personnel.
Permitted operating temperature of 10°C–30°C must not be
exceeded.
SF117 series, SF118 series, SF154 Emergency Call Stations:
Locate emergency stations where convenient for operation.
Avoid areas where direct contact with water may occur. The
SF117 series and SF118 series include a 6' long pull cord,
permitting installation high enough to provide easy opera-
tion by the staff and by seated or prone patients. The SF154
is operated by means of a push button located on the station.
IR019, IR019B Remote Annunciator Tone Speakers:Locate
annunciator tone speakers as needed and where convenient
for operation. Location must provide for unobstructed
visibility of the tone-off indicator (IR019B).
LI118B, LI123B, LI381, LI382, LI382LED Corridor Lights:
Locate corridor lights in the corridor above or beside the
door of the associated rooms. Location must provide unob-
structed visibility of the corridor light in both directions.
PK2019, PK2019A Control Unit: The PK2019 or PK2019A
may be surface mounted adjacent to the SS106, if necessary.
If remotely located, cable run from PK2019/A to CM800/
CM900 must not exceed 100'.
PK601A Power Supply: Surface mount the PK601A adjacent
to the SS106 and PK2019/A.
PK612A DC Flasher: Surface mount the PK612A adjacent to
the SS106 and PK2019/A.
®
• 42 Central Drive • Farmingdale, NY 11735-1202
Section C
Rev. 13 - 5/2011
System Installation
Installation Procedure
Equipment Locations